Loading...
HomeMy WebLinkAboutMISC EMAILArchitectonic Inc St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 December 15, 2017 a"-- ()�p Or 001h )(�� � �grz DEC 2 8 2017 PEH7,III—, n?G St- Lucie Court,, FL RE: 12500 Okeechobee Road Garage Door Replacement SCANNED By To Whom It May Concern: St. Lucie County Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2014 Florida Building Code, 160mph wind zone, exposure "C", risk category II. From Table 1609.3.1: Vuit= 160mph Vasd= 124mph From Table 1609.7(1): 9'h x 12'w door, 160mph = 21.8- -24.3 From Table 1609.7(2): 20' mean roof height, Exposure C = 1.21 Required Design Pressures: 21.8 x 1.21=26.3 -24.3 x 1.21= -29.4 Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3 Product Pressures: +36.0 & -41.0 ST. UCIE CONBTJL''DLNG DIVISION REVIEM'ED FOR CO L*,AriCE REVS, WED B t _ DATE I . PLANS AND PERISH UST BE IaPT ( JOB OR NO LNSPECTION `ML BE MADE. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #tAA26003348 1 of 1