To Whom It May Concern: St. Lucie County
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2014 Florida Building Code, 160mph wind zone,
exposure "C", risk category II.
From Table 1609.3.1: Vuit= 160mph
Vasd= 124mph
From Table 1609.7(1): 9'h x 12'w door, 160mph = 21.8- -24.3
From Table 1609.7(2): 20' mean roof height, Exposure C = 1.21
Required Design Pressures: 21.8 x 1.21=26.3
-24.3 x 1.21= -29.4
Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3
Product Pressures: +36.0 & -41.0