Loading...
HomeMy WebLinkAboutMISC EMAILArchitectonic Inc SCANNED St. Lucie County Planning &Development Services BY St. Lucie Coltr,t� y Al`: Building&Code Regulation Division g r:'3 q t'' u I� Q,F ,� {� � CMVEE) 2300 Virginia Ave. �; Fort Pierce, FL 34982lal DEC 2 0 2017 December 15, 2017 peraj,l� fiat` St. Lucie Ccu;;i,; FL RE: 15601 Orange Avenue Garage Door Replacement To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2014 Florida Building Code, 160mph wind zone, exposure "C", risk category II. From Table 1609.3.1: V ii= 160mph CONCEALED FASTENERS OR ATTACHMENTS Vasd= 124mph ARE THE RESPONSIBILITY OF THE From Table 1609.7(I): 14'h x 16'w door, 160mph = 21.89-24.3 CONTRACTOR OF RECORD From Table 1609.7(2): 20' mean roof height, Exposure C =1.21 Required Design Pressures: 21.8 x 1.21=26.3 -24.3 x 1.21= -29.4 Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3 Product Pressures: +36.0 & -41.0 ST. LUCIE COUNTY BUILDING DIVISION REVIEWEDHOE FOR CO REVIEWED By DATE PLANS AND PE MIT MUST BE KEPT ON JOB OR NO INSPECTION WILL B� E 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1