December 15, 2017 peraj,l� fiat`
St. Lucie Ccu;;i,; FL
RE: 15601 Orange Avenue Garage Door Replacement
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage door is in compliance with the 2014 Florida Building Code, 160mph wind zone,
exposure "C", risk category II.
From Table 1609.3.1: V ii= 160mph CONCEALED FASTENERS OR ATTACHMENTS
Vasd= 124mph
ARE THE RESPONSIBILITY OF THE
From Table 1609.7(I): 14'h x 16'w door, 160mph = 21.89-24.3 CONTRACTOR OF RECORD
From Table 1609.7(2): 20' mean roof height, Exposure C =1.21
Required Design Pressures: 21.8 x 1.21=26.3
-24.3 x 1.21= -29.4
Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3
Product Pressures: +36.0 & -41.0
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWEDHOE
FOR CO
REVIEWED By
DATE
PLANS AND PE MIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL B� E
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1