Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 605 Kitterman Rd Building C City / State / Zip: Port St Lucie , FI 34981 Parcel #: 3415-707-0001-000/0 Zoning: CG APPLICATION INFORMATION f Permit Number: 1712-0019 �-Permit Type: BUILDING COMMERCIAL '`CONTRACTOR INFORMATION Contractor Name: Kim R Welsh Business Name: Welsh Construction Llc Business Addr: 3845 W Eau Gallie Blvd Ste 101 City / State / Zip: Melbourne, FI 32934 REVIEWS AND COMMENTS Review Ty rye -ADDRESSING ASSIGNMENT Comment: DOCUMENTS MISSING 12/112017 Comment: `. 12/1/2017 Comment: 1211/2017 Comment: i. 1211/2017 Comment: 12/19/2017 Comment: 12128/2017 Comment: 3/30/2018 Comment ENVIRONMENTAL REVIEW - Comment: FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: REVIEW COMMENTS SCANNED BY St. Lucie County 1 Owner(s): Farrell Advantage Pt St Lucie Holding Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 321-362-2582 Email: Ken@Welshci.Com Status Reviewed By Date Started Date Completed Date Released COMPLETE Lori Bender 12/19/2017 12120/2017 1212012017 PENDING Lashahna Ingram NEEDS ELECTICAL SUB NEEDS PLUMBING SUB NEEDS ROOFING SUB NEEDS HVAC/MECH SUB A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION. VEG PERMIT FILED UNDER (F) FOR FARRELL ADVANTAGE FOR PERMITS 1712-0015, 1712-0018, 1712-0019 AND 1712-0020. FEE POSTED ON PERMIT 1712-0015. RECORDED NOC LISTING WELSH CONST. AS CONTRACTOR. COMPLETE Lynn Swartzel 1212112017 12127/2017 1212712017 PENDING Tony Jerger COMPLETE Lashahna Ingram 12/1/2017 12/1I2017 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Faz:(772)462.6443 REVIEW COMMENTS PE REVIEW COMMEN7$121 I INCOMPLETE Joe Ciclo 5115/2018 Comment: CONTRACTOR TO SUBMIT [ 41 ORIGINAL, SIGNED, SEALED AND DATED SOIL TESTS FROM TIERRA SOUTH ALL OF THE TESTS SUBMITTED ARE COPIES AND ARE FOR A 2 STORY BUILDING' PLEASE IDENTIFY IN 2/14/2018 /10 THE TEST REPORTS THAT THERE ARE [ 31 INDIVIDUAL SINGLE STORY BUILDINGS AND [1 ] 3 STORY BUILDING • SEPARATE THE REPORTS FOR EACH BUILDING'•" SECOND REVIEW "`• RECEIVED [ 3 ] STILL NEED[1] 2/14/2018 Comment: ♦ THE TEST CRITERIA ON SHEET S001.0 [ 02300 EARTHWORK I IS NOT WHAT HAS BEEN SUBMITTED FOR 7REVIEW "'• NOT REVISED TO CURRENT REVISED TESTING •`•` Comment: /SUBMIT AN ORIGINAL, SIGNED, SEALED AND DATED STRUCTURAL INSPECTION PLAN IN TRIPLICATE, 212012018 ENERATED BY THE DESIGN PROFESSIONAL OF RECORD TO BE USED BY THE THRESHOLD INSPECTOR SSEE FBC 110.8.1 'THIS IS NOTED WITHIN SECTION III /NOTE 41l1 SHEET 5001.0 ""SECOND REVIEW •"' 001.0 PLAN STILL CALLING FOR THRESHOLD ENGINEER INSPECTIONS'•" Comment: jr/UBMIT A NOTARIZED, ORIGINAL LETTER FROM THE FEE OWNER OF THE BUILDING AS TO HIS/HER 2/20/2018 SELECTION OF HIRING THE SPECIAL INSPECTOR AND PAYING ALL COSTS •' SEE FBC 110.8.3 FOR THE REQUIREMENTS — PLANS STILL CALLING FOR THRESHOLD INSPECTIONS •'" Comment:, E SPECIAL INSPECTOR TO FILL OUT THE ST LUCIE COUNTY FORM FOR SPECIAL INSPECTORS AND 2/2012018 DENTIFY WHO WILL BE MAKING THE FIELD INSPECTIONS WITH APPROPRIATE LICENSE NUMBERS'•" PLANS STILL CALLING FOR THRESHOLD INSPECTIONS ••" Comment: SUBMIT [ 31 ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD COMPLIANCE " SHEETS #VCOMPLETELY FILLED OUT IN ORIGINAL FORMAT, THEN SIGNED, SEALED AND DATED BY YOUR DESIGN / PROFESSIONAL •• THESE ARE AVAILABLE ON OUR WEB -SITE'•'• SECOND REVIEW •••• SHEETS 2/20/2018 / INCORRECT OR INCOMPLETE •• OCCUPANCY TYPE IS S-1, CONSTRUCTION TYPE IS IIB AND 5B / NOT VVV BEARING WALL SYSTEM ? - WILL NEED [ 3 ] ORIGINAL, SIGNED,SEALED AND DATED SHEETS FOR EACH BUILDING PERMIT A,B,C AND D WITH THE PERTINENT PRESSURES ETC FOR THAT SPECIFIC BUILDING' BUILDING C IS 28 • BUILDING A,B AND D ARE 5B . Comment: SUBMIT[ 3 ] ST LUCIE COUNTY " PRODUCT REVIEW AFFIDAVITS SIGNED, SEALED AND DATED IN qV ORIGINAL FORMAT' BE SURE THAT THESE SHEETS ARE COMPLETELY FILLED OUT NOT " PER PRODUCT APPROVAL "' THESE ARE AVAILABLE ON OUR WEB -SITE ••" SECOND REVIEW "•• SHEET A-321.00 AND A- 2/20/2018 320.00 SPEC OVERHEAD DOORS BY JANUS AND PRODUCT AFFIDAVITS SPEC DCBI 690 SERIES ?? , PLEASE SUBMIT [ 3 ] ST LUCIE COUNTY" PRODUCT REVIEW AFFIDAVITS " NOT CITY OF PORT ST LUCIE / SUBMIT [ 3 ] IF CLADDING REMANS THE SAME FOR ALL 4 BUILDINGS OTHERWISE WILL NEED [ 3 ] FOR EACH BUILDING PERMIT [ BUILDING A,B,C AND D I • BE SURE THAT THESE AFFIDAVITS CO-INCIDE WITH ALL PLAN NOTES AND PRODUCT APPROVAL INFORMATION PROPOSED FOR USE Comment: SUBMIT IN TRIPLICATE, ORIGINAL ENGINEERED SHOPS WITH CALCULATIONS FOR THE STAIRCASES, 2/22/2018 /®LANDINGS, GUARDRAILS AND HANDRAILS WALL CONNECTIONS/ MUST BE REVIEWED AND APPROVED BY P.E. MURRAY BRYNTESEN' SEE NOTES S001.0 AND FRANK RELF [ SEE NOTES ARCHITECTURAL DRAWINGS "• SECOND REVIEW "• NOT RECEIVED Comment: SUBMIT IN TRIPLICATE ORIGINAL S.S.D. ENGINEED SHOPS FOR TI_IE FABRICATION AND ASSEMBLY OF 2/22/2018 /OPTHE STRUCTURAL STEEL ROOF SYSTEM PER AISC STANDARDS [ SEE S001.0I • MUST INCLUDE ALL V CONNECTIONS AND WELD SPECS •• THESE SHOPS MUST BE REVIEWED AND APPROVED BY P.E. MURRAY BRYNTESEN "' SECOND REVIEW •`• DID NOT RECEIVE Comment: �y SUBMIT TRIPLICATE, ORIGINAL, ROOF TRUSS LAYOUTS W- ENGINEERS CUT SHEETS FROM THE 2/22/2018 /'" MANUFACTURER FOR THE LIGHT GAGE TRUSSES • THESE SHOPS MUST BE REVIEWED AND APPROVED ✓ BY P.E. MURRAY BRYNTESEN `•• SECOND REVIEW "• DID NOT RECEIVE Comment: SUBMIT TRIPLICATE PLANS WITH SPECIFICATIONS FOR THE PARKING LOT LIGHT POLES W/ FOUNDATION ESIGN TO MEET 150 M.P.H. WIND LOADS, EXPOSURE C • SUBMIT IN TRIPLICATE [ SEE C-600 ] PLANS 2/22/2018 MUST BE FOR THE POLE / FIXTURE AND BRACKET COMBINATION' PLANS MUST BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD `•• SECOND REVIEW •" DID NOT RECEIVE 2122/2018 Comment�UBMIT TRIPLICATE, ENGINEERED S.S.D. SHOPS FOR THE STEEL FLOOR ASSEMBLIES' THESE MUST BE REVIEWED AND APPROVED BY THE STRUCTURAL E.O.R. "• SECOND REVIEW... DID NOT RECEIVE Comment: /,THE SQUARE FOOTAGE ON THE PLOT PLAN ON T-000.00 FOR BUILDING D IS INCORRECT'••• SECOND 2/22/2018 V VIEW STILL INCORRECT FOOTAGE "•• SHEET A-106.00 SHOWS DIFFERENT OUTSIDE DIMENSIONS AND SHOWS THE BUILDING TO BE 155' LONG •.PLOT PLANS ON T-000.00 IS 135' LONG AND SHOWS THE 15, AND 20' DIMENSION REVERSED • PLEASE CHECK ALL PLANS FOR CONSISTENCY Comment: /SUBMITTHE MANUFACTURERS SPECIFICATIONS IN TRIPLICATE FOR THE ELEVATOR SYSTEMS, 3/8/2018 V�tEVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD "• NOT RECEIVED •" SECOND REVIEW 3/9/2018 Comment: CONTRACTOR TO PAY ALL CURRENT PLAN REVIEW FEES UPON RE -SUBMITTAL OF DOCUMENTS �.f-urirG �ocr-ri� Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 Comment: PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ' ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET 3/9/2018 OF PLANS CAN BE SUBMITTED PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 i 3/9/2018 Comment: MMENTS E-MAILED AS OF THIS DATE •'••• END FIRST REVIEW ••"' Comment: PER PLAN SHEET S001.0 THE BUILDINGS HAVE BEEN DESIGNED TO 160 M.P.H. EXPOSURE C / PER PLAN SHEET S002.0 THE ULIFT AND SERVICE PRESSURES ARE DESIGNED TO 170 M.P.H. EXPOSURE C' THE 5/15/2018 BUILDING, COMPONENTS AND CLADDING MUST MATCH •'• DESIGN PROFESSIONAL TO SHOW ALL WINDOW AND DOOR FLASHING ON PLANS PER FBC 1405.4 Comment: THE ENGINEER IS SPECIFYING 10 MIL VAPOR BARRJER AND THE ARCHITECT IS SPECIFYING GRACE 5/15/2018 PREPRUFE WATERPROOFING MEMBRANE????? t/ Comment: THE DESIGN PRESSURE TABLES CALCULATED BY ENGINEER ON S002.0 MUST CO-INCIDE WITH THE PRESSURES ON THE PRODUCT AFFIDAVITS BY FRANK RELF [ ARCHITECT I - THE CARLISLE ROOF 5/16/2018 _ COVERING PRESSURE IS TO LOW FOR THE ACTUAL PRESSURES' BE SURE THAT THE DESIGN PROFESSIONALS STATE THE PRODUCT APPROVAL NUMBERS ON THE S.L.C. AFFIDAVITS 6/16/2018 Comment: RE -REVIEW FEES DUE Comment: PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED 6/16/2018 PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 5116/2018 Comment: COMMENTS E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 211612018 2/23/2018 2123/2018 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 3/212018 31212018 31212018 Comment: "PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 211512018 Comment: OCCUPANT LOAD IS WRONG .ALL BUILDINGS MUST BE INCLUDED IN OCCUPANT COUNT FOR PLUMBING 2/15/2018 FIXTURE REQUIREMENTS PER SECTION 403.1 FLORIDA BLD CODE 2014 PLANS EXAMINER REVIEW COMPLETE Joe Ciclo 211412018 511512018 5115/2018 Comment: ZONING REVIEW COMPLETE. Lydia Galbraith 12/1912017 3/2312018 3123/2018 Comment: