Soil Nuclear Gauge
Report Date: 11/12/2018
Test Method: ASTM D 6938
Port St. Lucie, FL 34966
Phone: ]]2-9243575 1 Fav: 772-924-3580 0.
Client:
Park East Construction Corp.
266 E. Jericho Tpke
Huntington Station, NY 11746
18-3920.OD
Farrell Storage (Kitterman)
Kitterman Rd.
Port Saint Lucie, FL
Test Results
Test#
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
M
In Place
Dry Density
(pcf)
Probe
Depth
(In)
Percent
Compaction
Min/Max
Comp.
M
Remark
218
11/12/18
8306 - D1557
N/A
10.3
123.6
7.9
122.3
12
99
98 / 105
Pass
219
11112/18
8306 - 215N
N/A
10.3
123.6
8.3
121.8
12
99
98 / 105
Pass
220
11/12118
8306 - D1557
N/A
10.3
123.6
8.0
121.4
12
98
98 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
I Make I Model / SN I Calibrated
Field Technician
218
Below Slab Grade: Building D, NW Comer
0-1'
Troxler / 3430 124566
1Liverman, Robert
219
Below Slab Grade: Building D, Center Area
0-1•
Troxler/ 3430124566 1
Liverman, Robert
220
Below Slab Grade: Building D. SE Corner
0-1•
Troxler/ 3430 / 24566 /
Liverman, Robert
Remarks
Comments
Pass: Tests results Comply with specifications
Tests am 'Direct Transmission' (Method A) unless probe depth is noted as
'Backscattef . Gauge calibration data on file with the testing agenry.
RECEIVED
NOV 13 n18