HomeMy WebLinkAboutPRODUCT INFORMATIONREV. 11 MAY 2015 80002 HR Englnee�ifig, Inc. GATE; 2014,N.2012 PROJECT NO. ]10120001 SHEET .1. V of 4 . PLYGEM / GEORGIA- CLIENI: PACIFIC 8Y: A. REEVES PROJECTNAME VINYL SIDING INSTALLATION 16": STUD & NAIL SHEATHING 01 A VINYL = ITUDS Q y 4 ^ CGS x PLYGEM / GEORGIA-PACIFIC VINYL. SIDING INSTALLATION GENERAL, NOTES 1. NAILS ARE GALVANIZED STEEL ROOFING NAUS, 1-1/2" LONG, WITH 1/8" DIAMETER SHANKS, AND 3/8" DIAMETER HEADS. 2. ALL STUDS MUST HAVE NAILS IN THEM AND ALL NAILS MUST BE IN STUDS. 3. SHEATHING MUST BE NAILABLE WITH A MINIMUM THICKNESS OF 518", AND PLYWOOD MUST BE A MINIMUM OF V? THICK 4. FOR ALOWABLE DESIGN WIND LOADS ON VINYL SIDING USING THIS INSTALLATION PROCEDURE, SEE EVALUATION REPORT FOR PLYGEM / GEORGIA-PACIFIC SIDING. S. THE INSTALLATION DETAILS SHOWN ON THIS DRAWING ARE IN CONFORMANCE WITH FLORIDA BUILDING CODE 2014, PARAGRAPHS 1404.9 AND 1405.14; PLUS FLORIDA RESIDENTIAL CODE 2014, PARAGRAPH 703.11. N. RE��° No.19354 ' STATE OF '��� T�0RIP{j�.: S Op AG���``` J-4 /I/ 4y z o / S Allen N. Reeves, P.E., SECB S4ruchlrai Engineer Florida License No. 19354 a REV, 11 MAY 2015 14080002 HR Engineering, Inc. DATE. 20 JAN. 2012 c_[PR0JECrINAME- ROJECT No. 1I120001 SHEE7 -2 OF 4. CUENT:PLYGEM/ GEORGIA A. REEVES VINYL SIDING INSTALLATION PACIFIC SY: SHEATHING d 0 0 16"STUD SPACIN 95 VERTICAL VINYL SIDING; BOARD AND BATTTEN, • TRUEWALL BOARD AND a BATTEN, BEADED, D5 OR T3-1/3 PLYGEM / GEORGIA PACIFIC VERTICAL VINYL SEDING INSTALLATION GENELBAL NOTES L NABS ARE GALVANIZED STEEL ROOFING NAILS, 1-1/2" LONG, WITH 1/8" DIAMETER SHANKS, AND 3/8" DIAMETER HEADS. 2. STUDS.ARE NOT REQUIRED TO HAVE NAILS IN THEM. NAILS MUST PENETRATE THE SHEATHING OR PLYWOOD ONLY. 3. SHEATHING MUST BE NAILABLE WITH A MINIMUM THICKNESS OF 5/8", AND PLYWOOD MUST BE A MINIMUM OF %:" THICK. 4. FORALOWABLE DESIGN WIND LOADS ON VINYL SIDING USING THIS INSTALLATION PROCEDURE, SEE EVALUATION REPORT FOR PLYGEM / GEORGIA-PACIFIC SIDING. E I Ir c No.19354 S STATE OF =W� i� !p'jy'q'00 LE" c� 97, /& A? A04Y 2015 5. THE INSTALLATION DETAILS SHOWN ON THIS DRAWING ARE IN CONFORMANCE WITH FLORIDA BUILDING CODE Allen N. Reeves, P.E., SECB 2014, PARAGRAPHS 1404.9•AND 1405.14; PLUS FLORIDA Structural Engineer RESIDENTIAL CODE 2014, PARAGRAPH 703.11. Florida License No. 19354 a REV. =IMJAY201514080002 HR En ineeriR , In DATE: 1112000I 3 4. S txPPLYGEM/GEORGIAACL1EM PACIFIC 91 —ME: S»G LAfSTALLADN SHEATH NG OR PLYWOOD gxACING STUDS AT 16" SPACIAIG `b NARS AT 16" SPACING t FOAM BACKEDVINn SIDING CALIBER HIGJI PERFORMANCE et R PI.YGEM / GEORGIA^-PACIFIC FOAM BACKED VINYL. SIDING INSTALLATION GENERAL NOTES I. NAILS ARE GALVANIZED -STEEL ROOFING NAILS, 1-1/2" LONG, WITH 1/8" DIAMETER SHANKS, AND 3/8" DIAMETER HEADS. 2. ALL STUDS MUST HAVE NAILS IN THEM AND ALL MAILS MUST BE IN STUDS, WITH THE SINGLE EXCEPTION OF D6 WITH 8" NAIL SPACING, WHICH HAS % OF NAILS IN STUDS. 3. NAII-OLE SHEATHING AND PLYWOOD MUST BE A MINIMUM OF 5/8" THICK, EXCEPT FOR D6 WITH 16"NAIL SPACING, WHICH MUST BE'A MINIMUM OF %r THICK 4. ALLOWABLE DESIGN WIND LOADS ARE; +/-61.7 PSF ON D6 WITH 16" NAIL SPACING OR+/_95.7 PSF WITH 8" NAIL SPACING, 5. THE INSTALLATION DETAILS SHOWN ON THIS DRAWING ARE IN CONFORMANCE WITH FLORIDA BUILDING CODE 2014, PARAGRAPHS 1404.9 AND 1405.14; PLUS FLORIDA RESIDENTIAL CODE 2014, PARAGRAPH 703.11. `tttpuuuuuurr! -� r :• N'o 19354 :Q_ gyp'. STATE OF ;W\ 'Gt� �0RtV . lqunrn mnnWt�p /3 M.Qy 2 o JS Allen N. Reeves, P.E., SFCB Stnictuia( P-u&eer Florida License No. 19354 REV, I I MAY 2015 14080002 HR EB1 inew1i1 Inn. DAIS 20JAN.201z 11120001 4 4 ��r PROJECTNO. PLYGEMIGEORGIAv GLIEALT PACIFIC BY. A• RWTS PRQJEM HAND; VINYL S11DING INSTALLATION SHEATHING MARS AT ; ORPLYWOOD 8^ SPACING , STUDS AT , o 16" SPACING e PLASTIC SIDING ry CEDAR SPECTRUM e HAND SPLIT SHINGLE, SHINGLE, E7 U ROUND CUT SIDINGta � PLYGEM / GEORGIA-PACMC PLASTIC SIDING INSTALLATION GENERAL NOTES 1. NAILS ARE GALVANIZED STEEL ROOFING NAILS, 1-1/2" LONG, WITH 1/8" DIAMETER SHANKS, AND 3/8" DIAMETER HEADS. 2. ALL STUDS MUST HAVE NAILS IN THEM AND % OF ALL NAILS MUST BE IN STUDS. 3. NAH.ABLE SHEATHING AND PLYWOOD MUST BE A MINIMUM OF 5/8" THICK. 4. ALLOWABLE DESIGN WIND LOADS ARE; +/-65.0 PSF FOR DOUBLE 9" HAND SPLIT SHINGLE, +/-83.6 PSF FOR DOUBLE 7" SHINGLE, AND +/-74.9 PSF FOR DOUBLE 6-1/4" ROUND CUT SIDING. 5. THE INSTALLATION DETAILS SHOWN ON THIS DRAWING ARE IN CONFORMANCE WITH FLORIDA BUILDING CODE 2014, PARAGRAPH 1404.8 AND SECTION 2605. z ' `\���nuwnuu�uq ? No.19354 c /Ny `-p STATE OF ��` NIA1lE� ' 2 0./'5" Allen N. Reeves, P.E., SECB' Structural Engineer Florida License No. 19354