HomeMy WebLinkAboutPROJECT INFORMATION717-846-3747 HR HR Engineering, Inc. 1541 E. Market St. York, PA 17403 Alan F. Hoying Code and Regulatory Manager SCANNED PIYGem Siding Group BY 2405 Campbell Road St. Lucie County Sidney, Ohio 45365 RE: Florida Evaluation Report, Georgia-Pacific Siding, FBC 2014 Dear Mr. Hoying; GENERAL Fax 717-846-0355 REC'EIF ED DEC 0 5 2017 Pei -RairriNG St. Lucie County, FL 13 May 2015 This Florida Evaluation Report contains all of the 21 siding products manufactured by P1yGem / Georgia-Pacific. The report is divided into 4 different siding types; vinyl siding, vertical vinyl siding, foam backed vinyl siding, and plastic (polypropolene) siding. All of the work here is in conformance with the 2014 Florida Building Code and the 2014 Florida Residential Code. VINYL SIDING The following 12 PlyGem / Georgia-Pacific vinyl siding products; Parkside, Chatham Ridge, Vision Pro, Shadow Ridge, Forest Ridge, Castle Ridge, Somerset Beaded, Compass, Tmewall Series 3800, Tmewall Series 4000, Truewall Series 4200, and Tmewall Series 4400 have been tested and analyzed in .conformance with ASTM D 3679-09 as required by Florida Building Code 2014, paragraphs 1404.9 and 1405.14; plus Florida Residential Code 2014, paragraph 703.11. Structural testing to ASTM D 5206, as required by ASTM D 3679, is reported in ICC ES report ESR-1565. For configurations, thicknesses, nail hem types, horizontal and vertical nail spacings, plus allowable design wind pressures, see table beginning on page 2. I have performed a combination of rational and comparative analyses on these products, which includes the mandatory requirements of Annex A1.2.1 in ASTM D 3679. Installation must be over 5/8" minimum nailable sheathing or %:" minimum plywood. Installation fasteners must be roofing nails with 3/8" diameter head, 1/8" diameter shank, and a minimum length of 1-1/2". The allowable design wind pressures for all of these products have been determined in a separate 7 page structural analyses titled VINYL &, PLASTIC SIDING ANALYSES FLORIDA EVALUATIONS.& 2014 FBC UPDATE. In order to achieve the pressures in the analyses, all studs must have nails in them and all nails must be in studs. Studs must be at 16" spacing. For additional installation details, see drawing titled PLYGEM / GEORGLI PACIFIC VINYL SIDING INSTALLATION, Sheet 1 of 4, attached to this report. Georgia-Pacfic Page 2 Pl gem/Geor 'a -Pacific Siding Table Product Name Configuration Thickness Nail Hem Horizontal Vertical Allowable Nail Nail Design Parlside Vinyl Double 5" 0.038" Standard S ac*g 16" S acin 10" Pressure Siding D5 Dutchlap +/-74.6'PSF Tri le 3 1/3" D 4.5 Dutchlap 0.038" Standard 16" 9" +/-83.0 PSF Double 4" 0.038" Standard 16" 8" +/-g3.3 PSF D4 Dutchla Chatham Ridge Via I Siding Triple 3" 0.040" Standard 16" 9" +/-87.3 PSF Vision Pro Vinyl Siding Double 5" D5 Dutchl 0.040" Standard 16" 101, +/-7g.6 PSF Double,VI D4 Dutchla 0.040" Standard 16" 8" +/-98.2 PSF Shadow Ridge Vinyl Siding chlap D4 Dutchian 0.042" n ndw, Standard e.--A-_, 16" 101, +/_g2.5 PSF idge ding Doubles" 0.042" Standard 16" PS03 ++/-10 PSF Double 41' 0.042" Standard 16" 81, 3.1 idge ding Single 8" WS 0.044" Standard 16" 8" PSF +/-108.0 eaded Single 6 VP 0.044" Standard 16" 6 1/2" PSF Viaing +/-132.9 ss ing D4.5 DutchLap 0.044" Double 16" 9" PSF +/-114.7 - Thickness PSF m verucaivmyt Siding Double 5" 0.040"' Standard 10" 8" 1.., +/-55.7 PSF Nails in Nails in Sheathing Sheathing Double 5" 0.044" Standard Onl 10" Oak 8" +/-61.2 PSF Nails in Nails in Sheathing Sheathing T 31/3 Vertical Triple 3 1/3" O.O44" Standard Onl 10" Only 8" Vinyl Siding +/-61.2-PSF Nails in Nails kn Sheathing Sheathing Board & Batten 5 1/2"Board 0.048" Standard O7nl Only 7 Vertical Vinyl I '/z" Batten Nail s in Nails in+/-109.0 PSF Siding Sheathing Sheathing Beaded Vertical Siogle7" 0.040" Standard Onl OnlT' 7" Vinyl Siding Nails in Nails kn +/-90.8PSF Sheathing Sheathing Georgia-Paefic Page 3 Plygem/Georgia-Pacific Siding Table Continued Product Name Configuration Thickness Nail Hem Horizontal Vertical Allowable Nail Nail Design Caliber High Double 6" 0.046" Standard Spacing 8" S acin 12" Pressure Performance, Foam Y: of All Yz of All +/-95.7 PSF Backed Vinyl Nails in Nails in Siding Studs Studs Double 6- 0.046" Standard 16" 12" +/-61.7 PSF Cedar Spectrum Double 9" 0.100" Thickened 8" I8" +/-65.0 PSF Hand Split Shingle % of All Y2 of All Plastic Siding Nails in Nails in Studs Studs Cedar Spectrum Double 7- 0.100" Thickened 8" 14" +/-83.6 PSF Shingle Plastic Y: of All Ya of All Siding Nails in Nails in Cedar Spectrum Double 6'/. 0.080" Thickened Studs 8" Studs 12 I/2" +/-74.9 PSF Round Cut Plastic Y2 of All Yx of All Siding Nails in Nails in Studs Studs TrueviallSeries Double 5" 0.038" Standard 16" 10" +/-74.6 PSF 380 3800 DS Dutc Vinyl Siding D4.5 Dutchla 0.038" Standard 16" 9" +/_83.0 PSF Double 4" 0.038" Standard 16" 8" +/_93.3 PSF D4 Dutchla Truewall Series Double 5" 0.040" 7§tandard 16" 10" :608,6 PSF 4000 D5 Dutchlap Vinyl Siding Double 4" 0.040" Standard 16" 8" +/-98.2 PSF D4 Dutchlap Truewall Series Double 5" 0.042" Standard 16" lo" +/-82.5 PSF 4200 135 Dutchlap Vinyl Siding Double 4" 0.04T' Standard 16" 8" +/_103.1 D4 Dutchla True Series Double 5" 0.044" Standard 16 10" PSF +/-86.4 PSF 440 4400 Vinyl Siding D4.5 Dutchlap 0.044" Standard 16 9" +/-96.0 PSF Double 4" 0.044" Standard 16" 8" +/-108.0 Tmewall Board & 5 'h" Board 0.04V Standard 7 +/PSF 104.5 Batten Vertical 'h 1 "Batten Nails in Nails in PSF PSF Vinyl Siding Sheathing Sheathing OnlyOnl Georgia-Pacific siding Page 4 The allowable design wind pressures shown in the table on pages 2 and 3 of this evaluation report can be compared directly to the required wind loads in Chapter 16 of the Florida Building Code. If there are any questions about this, please contact me. VERTICAL VINYL SIDING The following 5 P1yGem / Georgia-Pacific vertical vinyl siding products; D5 Vertical, T 3-1/3 Vertical, Board & Batten, Beaded, and Truewall Board and Batten have been tested and analyzed in conformance with ASTM D 3679-09 as required by Florida Building Code 2014, paragraphs 1404.9 and .1405.14; plus Florida Residential Code 2014, paragraph 703.11. Structural testing to ASTM D 5206, as required by ASTM D 3679, is reported in ICC ES report ESR-1566. For configurations, thicknesses, nail hem types, horizontal and vertical nail spacings, plus allowable design wind pressures, see table, beginning on page 2 of this report. I have performed a combination of rational and comparative analyses on this product, Which includes the mandatory requirements of Annex A1.2.1 in ASTM D 3679. Installation must be over 5/8" minimum nailable sheathing or %:" minimum plywood. Installation fasteners must be roofing nails with 3/8" diameter head, 1/8"diameter shank, and a minimum length of 1-1/2". The allowable design wind pressures for this product have been determined in a separate 7 page structural analyses titled VINYL, & PLASTIC SIDING ANALYSESFLORIDA EVALUTAIONS & 2014 FBC UPDATE. Fasteners must be through sheathing and need not be in studs. Studs must be at a maximum 16" spacing. For additional installation details see drawing titled PLYGEM / GEORGIA-PACIFIC VERTICAL VINYL SIDING INSTALLATION Sheet 2 of 4, attached to this report The allowable design wind pressures shown in the table on pages 2 and 3 of this evaluation report can be compared directly to the required wind loads in Chapter 16 of the Florida Building Code. If there are any questions about this, please contact me. FOAM BACKED VINYL SIDING The following PlyGem / Georgia-Pacific foam backed vinyl siding product; Caliber High Performance has been tested and analyzed in conformance with ASTM D 3679-09 as required by Florida Building Code 2014, paragraphs 1404.9 and 1405.14; plus Florida Residential Code 2014, paragraph 703.11. For configurations, thickness, nail types, horizontal and vertical nail spacings, plus allowable design wind pressures, see table on page 3 of this report. Structural testing to ASTM D 5206, as required by ASTM D 3679, was done at Architectural Testing, Inc.'s main laboratory located at 130 Derry Court, York, PA 17402 and is reported in 01-50924.01 (test date 04/29/04) and in 01-50924.02 ( test dates 04/29/04 and 04/30/04). The material (physical) properties testing as required in ASTM Georgia-Pacific Siding Page 5 D 3679 was done at Architectural Testing, Inc.'s main laboratory located at 130 Derry Court, York, PA 17402 as reported in project A9142.01-103-77 (test date-10/11/11). The material was also tested. to ASTM E 119 "Standard Test Methods for Fire Tests of Building Construction and Materials" at Southwest Research Institute located at 6220 Culebra Road, San Antonio, Texas in project 01-033000.01.001 (test date-01/2000). I have performed a combination of rational and comparative analyses on this product, which includes the mandatory requirements of Annex A1.2.1 in ASTM D 3679. Installation must be over 5/8" minimum nailable sheathing or ''/2" minimum plywood. Installation fasteners must be roofing nails with 3/8" diameter head, 1/8"diameter shank and a minimum length of 1-1/2". The allowable design wind pressures for this product have been determined in a separate 7 page structural analyses titled VINYL & PLASTIC SIDING ANALYSES FLORIDA EVALUATIONS & 2014 FBC UPDATE. Stud spacing must be 16", and studs must be 2 x 4 minimum. With 16" horizontal spacing, all nails must penetrate studs, and with 8" horizontal spacing, '/2 of all nails must penetrate studs. For additional installation details, see drawing titled PLYGEM / GEORGIA-PACIFIC FOAMBACKED VINYL SIDING INSTALLATION Sheet 3 of4, attached to this report. The allowable design wind pressures shown in the table on page 3 of this evaluation report can be compared directly to the required wind loads in Chapter 16 of the Florida Building Code. If there are any questions about this, please advise me. PLASTIC (POLYPROPYLENE) SIDING The following 3 PyGem / Georgia-Pacific plastic (polypropylene) siding products; Cedar Spectrum Hand Split Shingle, Cedar Spectrum been tested as reported in ATI Evaluation ServiShingle, Cedar Spectrum Round Cut have ce report CCRR-0164, and determined by rational analyses to be in conformance with Florida Building Code 2014, paragraph 1404.8 and Section 2605. For configurations, thicknesses, nail hem types, horizontal and vertical nail spacings, plus allowable design wind pressures, see table on page 3 of this report. Structural testing to ASTM D 5206 was done at Architectural Testing, Inc.'s main laboratory located at 130 Derry Court, York, PA 17402 and is reported in 01-38984.01 (test date-3/15/01), 01-39563.01 (test date-6/27/01), 99352.04-109-44 (test date- 03/26/10), and 99352.05-109-44 (test date-03/25/10). Additional 'fire testing at Southwest Research Institute located at 6220 Culebra Road, San Antonio, Texas as reported in projects 01-2303.135 and 01-2303.136, in conformance with FBC 2612.2, has determined that these products have passed the ASTM D 1929 Self Ignition test and attained a class C-2 rating in the ASTMD 635 Rate of Burn test. I have performed a combination of rational and comparative analyses on these products. Installation must be over 5/8" minimum nailable sheathing or %2" minimum plywood. Installation fasteners must be roofing nails with 3/8" diameter head, 1/8" diameter shank, Georgia-Pacific siding Page 6 and a,minimum length of 1-1/2". The allowable design wind pressures for all of these products have been determined in a separate 7 page structural analyses titled VINYL & PLASTIC SIDING ANALYSES FLORIDA EVALUATIONS & 2014 FBC UPDATE. In order to achieve the pressures in the analyses, all studs must have nails in them, and % of all nails must be in studs. Studs must be at 16" spacing. For additional installation details, see drawing titled PLYGEM / GEORGLI PACIFIC PLASTIC SIDING INSTALLATION Sheet 4 of 4, attached to this report. The allowable design wind pressures shown in the table on page 3 of this evaluation report can be compared directly to the required wind loads in Chapter 16 of the Florida Building Code. If there are any questions about this, please contact me. Sincerely yours; LiL&-ell N, Allen N. Reeves, P.E., SECB Structural Engineer Florida License No. 19354 12 14A1z" 2 o /3 ANR:anr Cc: 14080002 � F No. 19354 • ice= .0' STATE OF ��