Stanley Access Technologies, LLC
65 Scott Swamp,Road
Farmington, CT 06032
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHD (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Dura Storm" Aluminum Automatic Sliding Glass Door: O-Sx-Sx-O, O-Sx and
So-Sx-Sx-So, So-Sx w/ Operable Panels w/ Full Breakout-LMI
APPROVAL DOCUMENT: Drawing No.14-1856, titled "Series Dura-Storm 2000/3000 Auto SGD, Bi-
Parting/Single Slide (LMn", sheets 1 thru 14 of 14 prepared by Engineering Express, dated 07/01/12, and last revised
on 08/23/17, signed and sealed by Frank L. Bernardo, P.E., bearing the Miami -Dade County Product Control Renewal
stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact
LIMITATIONS:
1. See elevation for anchors requirements in sheet 1 and Header clusters details in sheet 5 and Threshold clusters in
sheet 9. See sheets 2 & 3 for concealed 3-point locking (active panel) & 2-point (in -active). Also see applicable
2-point G-86 CVR panic devices (active/inactive panels) for series 3000 in sheets 3 & 4 to be used w/ Horizontal
muntin bars (detail V, sheet 12) and DLO height not to exceed 36-3/4" max.
2. Not approved where water infiltration is required. Fixed glass more than 36" wide must be supported with
approved setting blocks per FBC requirements.
3. Electrical devices, functions and installation are not part of this approval and are to be reviewed and approved by
Authority Having Jurisdiction (AHJ).
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and
following statement: "Miami -Dade County Product Control Approved", noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
1.11
MIAMMADE COUNTY (�3k-(2° t Y NOA No. 2
I Expiration Date: April
04,202323
FIL O Aopproval Date: March 22, f 8
Page 1 of 2
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews #17-0828.11 and consists of page 1, this page 2 and evidence pages E-1, E-2 & E-3, as well as
approval document mentioned above.
The submitted documentation was reviewed by Jorge M. Plasencia, P.E.
C
G.��._ dam•,
NOA No. 18-0221.11
Expiration Date: April 04, 2023
Approval Date: March 22, 2018
Page 2 of
Stanley Access Technologies, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA'S
A. DRAWINGS
1. Manufacturer's die drawings and sections (submitted under file see below).
2. Drawing No. 14-1856 (former 12-SAT-13), titled "Dura-Storm 2000/3000 Auto SGD,
Bi-Parting/Single Slide-LMI", sheets 1 thru 14 of 14 prepared by Engineering
Express, dated 07-01-12 and last revised on 10/15/2014, signed and sealed by Frank L.
Bennardo, P.E.
B. TESTS (submitted under files 413-0529.23/912-0807.03)
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94 (Not conducted)
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
Along with installation diagram of aluminum automatic entrance doors Sx-So w/ G-86 CVR
Panic (TAS 202, 201/203-94) and So-Sx-Sx-So w/ Transom & G-86 CVR Panic (TAS 202),
prepared by Fenestration Testing Laboratory, Inc. Test Report No. FTL-7247, dated 3/08/13,
signed and sealed by Marlin D. Brinson, P. E
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94 (Not conducted)
4) Large Missile -Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
Along with installation diagram of aluminum automatic entrance doors, prepared by
Fenestration Testing Laboratory, Inc. Test Report No. FTL-6803, dated 05/11/12 and last
revised on 03/21/13, signed and sealed by Marlin D. Brinson, P. E.
Note: This test report has been revised by an addendum letter dated Nov 21, 2012, issued by
Fenestration Testing Lab, signed and sealed by Marlin D. Brinson, P. E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-2014
(51 Edition), prepared by Engineering Express, dated 05-13-15, signed and sealed by
Frank L. Bennardo, P.E.
2. Glazing complies w/ ASTME-1300-02, -04 & -09.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
Jorge M. Plasencia, P.E.
Proauct Control Unit Supervisor
NOA No.18-0221.11
Expiration Date: April 04, 2023
Approval Date: March 22, 2018
E-1
Stanley Access Technologies, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No.13-1105.10 issued to SAF-GLAS, L.L.C. for "SAF GLAS,
Polycarbonate laminate", expiring on 12/16/17.
2. Notice of Acceptance No. 11-0624.01 issued to E.I. DuPont DeNemours & Co., Inc.
for their "DuPont PVB Butacite ®", expiring on 12/11/16.
3. Technical strength data of Trelleborg EPDM per ASTM C864.
F. STATEMENTS
1. Statement letter of conformance to FBC 2014( 5w Edition), prepared by Engineering
Express, dated May 13, 2015, signed and sealed by Frank L. Bennardo, P.E.
2. Statement letter of no financial interest, prepared by Engineering Express, dated 08-
02-12, signed and sealed by Frank L. Bennardo, P.E. (submitted under file # 12-
0807.03)
3. Lab compliance as part of the above referenced test report.
G. OTHER
1. This NOA revises NOA 913-0529.23,expiring 04/04/18.
2. Test proposals # 13-0006 dated 01/14/13 approved by RER and # 11-1016, dated
NOV 11, 2011 approved by PERA and Test proposal # 11-1016, dated NOV 11, 2011
approved by PERA.
3. Manufacture supplied Adam Rites deadbolt/hook & bolts mechanism and G-86 CVR
Panic exit brochures.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 17-0828.11
A. DRAWINGS
Drawing No.14-1856, titled "Series Dura-Storm 2000/3000 Auto SGD, Bi-
Parting/Single Slide (LMI)", sheets 1 thru 14 of 14 prepared by Engineering Express,
dated 07/01/12 and last revised on 08/23/17, signed and sealed by Frank L. Bennardo,
P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th
Edition (2017), prepared by Engineering Express, dated 08/07/17, signed and sealed
by Frank L. Bennardo, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
ge M. Plasencia, P.E.
Product�Control Unit Supervisor
NOA No. 18-0221.11
Expiration Date: April 04, 2023
Approval Date: March 22, 2018
E-2
Stanley Access Technolmdes, LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued Kuraray America, Inc. (formerly
DuPont) for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers",
expiring on 07/08/19.
F. STATEMENTS
1. Statement letter of conformance with FBC 6th Edition (2017), prepared by
Engineering Express, dated 07/31/17, signed and sealed by Frank L. Bennardo, P.E.
G. OTHER
1. This NOA revises NOA #15-0127.07,expiring on 04/04/18.
3. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. None.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No.17-1026.04 issued to SAF-GLAS, L.L.C. for "SAF GLAS,
Polycarbonate laminate", expiring on 12/16/22.
2. Notice of Acceptance No. 17-1114.14 issued Kuraray America, Inc. (formerly
DuPont) for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers",
expiring on 07/08/19.
F. STATEMENTS
1. None.
G. OTHER
1. This NOA renews NOA #17-0828.11, expiring on 04/04/18.
rge M. Plasencia, P.E.
Product Control Unit Supervisor
NOA No. 18-0221.11
Expiration Date: Apri104, 2023
Approval Date: March 22, 2018
E-3
13• MA% ANCHORS AT FEAD, SEE SHEE
V /%DETAILS AND cHOR cw�EF
D:
m
0
10
1
b
bb
/\r
4*3e'Z
o
o
n:
i
b®
a m
♦♦
r`
a b®
216
Ma
°SX.\\
II /
_
2/
N
//°
1
40"
F'— 1/6 O—SX—S%-0 (BI—PART)
9
I \ ®4
\
♦bb
/l
2-F
T LOCK
II RppTT LOCK
\
i
OR
z
2
P�CLIMOANIC
CVR
ES/
��
I
� m
n
\
im`
®bb
♦b0
I
�
\
43.4' MAX
/
U
\\
mKTIP/
II
JI„v
I
3 qqT
`ILOCR\
I�
54 6" M
AVf1 W701H
a
', •- ^cam
6
m
"
1 1
wM14n 4/7.6 SO—S%—S%-50 (BI—PART) r
�RJbvCN wfnm.�iw.
Mevlw 1603]1.11
°4 DURA—STORM 3000 TYPICAL ELEVATIONS
i t
N TESTED h DEIGNED IE
M OF ME FLORIDA BURL
O ME 11LORIDA BUILDING
�•'. H $$� �
YNIII-VADE-COUNTY PROTOCOLS TAS "I MR OdWig"'AE
"F .
"' MPX PA GE VJIDT
WPA , TAB 202 FOR UNIFORM STATC AR PRESStJj q "D
203 FOR CYGLC RIND LOADING. X :
OF THE
4"
BS b0 _-
0
1 6
2. PERMIT HOUMA SH4L1 VERIFY THE ADEOVACTT
VRIHSTMO
® _
O
4N
EXISTING mWPURE TO MORIONAI fMRO5E0
W.Ds. I% OR 2% WGW Rum BY OMERs SN5101ggE 3T�F
ANCHORED PROPERLY TO TMNSGM LAMS TO THEOlXISiU�'
sI umm
3 NO INCREASE IN ALLOWABLE SiRE55 HAS IEEpY4 1N
WE DEIGN OF THESE PPOOUCR. WINO IDAD DU10yy AL
iACTOR CC a 1b WAS MEO FOR WOOD ANCHOR DESIE41,
• w,yE �><
%j
_
bb
♦
¢`
W
"m -
\
4. POSHAND HEGATIVE DESIGN PRESSURES CAIDULATED
IVE
FOR USE WITH TINS SYSTEM sMM BE OETFRMMW PEA
<I Ii 3B
m
1
_z %
N
EEPMATE Mclu ING M ACCORDANCE WI1H THE COvER"0
R
Z S
W 9
X
0
CODE PRESIIPE RIGUIREHEM AS OEIEAIDNED M
ACCORDANCE WTH ASCE 7 AND GRAPIER 160G OF ME
FLOPoDA BUILDING CODE SI BE 1F55 11ON OR EOVAL TO
$tib
3 5
ME POSILNE OR NEGATIVE DESIGN PRESSURE CAPACRY
VALUES USTED HEREON FOR MY ASSEMBLY M EHOWN.
I$ N
b O
5. OESRN PflE55UREs NOTED HEREIN ME BASED ON
UAIDMUM TESTED PR65URES DINGED BY A 1.6 SPFEIY
®b4.2.
®b
3'PT LOCK
OR2—PT
CVRPANIC
\
1
5X
/
S()
SHILL SE
WD
ON
ON
S
vu
s
Lm•sIn
G
Z
FOAM
E%
G
-
6
s ME
RLriY00D.
2
a
tz C h
ONE'
'O
$ uLo
EXRNIG
�
SME
�I.YWOOD.
« fv
z uzi
DES NOT
bd
CCf
�..a*yr'"HI
13, ALL SMOTE SLIDE E]TRMCES ARE SHOWN 'RIGHT HIND'.
vm\i 1FFT HAND' IS MIRROR IMAGE PRODUCT NEVIsBD
xoaxa 1]-0628.11
Bill
gig
��i
e.Pu.uoo o.
�dCMM.
oNI mDo6
vY
1. ALL "N11 M PARR SHALL BE 6063-T6 ALUMINUN
p(
A DY AND TEMPER UD.SS OTHERWISE NOTED.
2. G NG 9/16, LWIMTED 01PACT MTED (SEE G ING
g
OETNLS SHEET 12)
888333
3
FFF
]. CORNEA PANEL OONSMMDON: PANEL CORNERS ME
6/7,8
P
BUR JOINED, SECURED WITH FOUR (4) FULL WIDTH 5/16'
1 THREADED TE RODS AT TOP PAR, INIERMEDMTE HORIZOMA
UUMIN BM MD BOTTOM MIL A JOMR ME WELDED
4 . 7,6 SX-SO (SINGLE SUDE) IL
IF Lam+
ENCEPIION: 'MIEN PANIC EXIT DEVICE R INSTALLED,
MI CORRESPONDING 4 1/4' MUN BAR IS SECURED BY
MPROVED CUPS. (REM 17% 6HFET 12, DRaL N
4. THE GLADNG WTERNL M BOTH MED AND SLIDING
PMEDS OF ALL SLIDING DOORS MUST CONPLY MM TIE
14-1
6� LLHP4SEH
REW WEAIENR IN ME PERFORWNCE SPEMRMIONS MD
THRESHOLD. SEE SHEET 6 FOR
ANCHOR CLUSTER DIMENSIONS.
NEMODS OF TEST FOR S4 CVSMG NA E MOD IN
BUILDINGS, PER FBD RECUNEMEM.
5. CVR a CONCEALED VEA ROD.
OP
SERIES 2000 ELEVATION AND PLAN
10 ,
l0
1 2
r>
11 1
17 IB
LI
2 �K
/
✓�a
lz o
—
3-PT LOCH
NE
®:IO(TRUSION
EXTERIOR ELEVATION
P](TRUSION, MULTI -PIECE
EXTRUSION, OPTION
®: PART
XX XX : PART, MULE -PIECE
168'
BE: PART, OPTION
PACKAGE WIDTH
O: DETAIL
INTERIOR
l0f %X: DETAIL, OPTION
___ Or
---- __—
_
—�---
EXTERIOR
°SX' 'SX'
OPEEMERGENCY REAI(OLE UTf
PLAN
NOTES.. MI WOR SHOWN. STUE RAIL AND MUM OPTIONS AVPIIABUE AS INOIGim.
3. 5-�POeR LOCKINGG STP DARD (R-PIIRAE4IV�E IN)I SEE SHE£( 1UMEi. MM DLO: !8 1/1• W X ]9 !/4' H A9 SHOWN
4. PRWULT SPWL BE W. CWTURED AND INSTA W pCCOR M WTIH PRODUCT APPROVALS
5. SEE SHEER 5. 6 AND 91 MR REQUIRE) ANCHORAGE
8. BE SHEET 12 MR G"G DETMM
Ia11W1
I N
M
PMNAOE
Y'DIII
INUGM
OPfWW:
SNL
TYPE
6ER
NHm
Pm
tt9M
PY
YOM (OJ
��
CPF�Nf1G
t
t
]Od•
1i]'
41]
t/4 9K
tBev
W teas'
Dll
ee.B
A1.4
I 43.4•
1 a smE
1p O I- A D
PIL'JL•E 0.00011 WVWAt CIFM CAIWU
ImWf. ORM1B ttV.P CPG1M0 ILWMYE
80.0- 061' e0.5' 141C4
SERIES 3000 ELEVATION AND PLAN
Z
\
\\ ®hh
7 r
9 /h-
N
\ 9 6hh
7
\
1 2 u
2 11
2-PT LOCK
OR
3-LOCK
lOR
11 1
MUNTINS\
1 16 c
PT C
2-PT CVR
OPTIONALl
C_
IC
-PANIC
3
6
\\17 8
18 17
18 17
36 1/4
M
\
V
1
DLO
1920 n
15 16
6 S
'SX\
/
/YE
so-
�
E Mn
®: EXTRUSION
EXTERIOR ELEVATION
EXTRUSION, MULTI -PIECE
®: EXTRUSION, OPTION
®: PART
®: PART, MULTI -PIECE
STANDARD
X% XX : PART, OPTION
PACKAGE WIDTH
DETAIL INTERIOR — ' --
-----
DETAIL, OPTIO
'so' J
-sX' _sX".
EXTERIOR /
.
/
/CLEAR\
\
EMERGEFULL
NCY
BREAK OUT
DOOR OPENING
PLAN
Is
SFAFS
]OCO
BLPAR MI➢IIDE PIUAL£ MmIN
l`NNAiY1N
/
HDYN4
PN101H
PA\TL
Pµa
_
OPfWNYMO
IIPE
DOOR
OW (
WWp711X (0)
NLWA'KE
OPNIWO
tfi9.0
fe6!
Na
4vl
at'
t ♦ SINE
1�0
1cM15
00.l
4lA
4lA
14 9M
NOTES
I. TYp L DOOR SHOWN. 511E HAL AND IJUNRN OPTIONS AVANBLE AS WOKATED.
2 HORIZONTAL JUMW BAR NOT REWIRED EXCEPT AT PANIC DEVICE, AS INDICATED BY DASHED LINES. HAX DLO: 36 1/4' W X 75 3/4' H AS SHOWN: 36 3/4' H WIH PANIC DEVICE MUNRN.
3. 9-POIM CIR IDCK9JG WITH Ce6 PANIC REIFASE (2-PT LYR ACINE 4 2-PE LVAT AND 5- 117 UXNGNG (3_PT DIJINE h 2-Ph AVA ABIE SEE SHEET 11
4. PRODUCT SHELL BE PANUFACIlM AND INSTALLED W PIX:ORDANCf WDH PRODUCE APPRWAIS.
S. SE£ SHEETS S. 7, B. AND 9 MR MUM ANCHOPIGE
6. SEE SHEET 12 MR OIAZWG DETAILS.
uA Nu
P/D'JLf
FPM'11 NOYPVL CIFM
CILLKYa
rypLM
OP�}UXC Kqi DRNIW
ALLObIICE
Q
s C
MOANa tT-0B28.tt
nmr,w.P.e.Da04rz91B
at
YYm up wNo
) f )
11 SERIES 2000/3000 SINGLE
108,4 PACKAGE WIDTH a L s
4 ..:5 5 6 .. -
5
�LOCR�
tqq
lS
�c to
y
1qqqO
�`�
� 47 ,5/4 MAX
E'n !.SX.;
=ae
Y :SERIES 2000 (SX O)-SINGLE-SUDE
EXTERIOR ELEVATION -
INTERIOR I _
---�---- -- EXTERIOR
SX'
.0. ®:EXTRUSION
CLEAR
)OOR OPENING @@: EXTRUSION, MULTI -PIECE
OPERABLE &@:EXTRUSION, OPTION
\ EMERGENCY ®: P
ART
BREAKOUT Pp: PART, MULTI -PIECE
SERIES 2000 (SX 0)NINGLE SUDE XX XX: PART, OPTION
LA O; DETAIL
XX XX : DETAIL, OPTION
PLAN
DETAIL
n
e
\
2
1
pLOCK\\
11 1 \\
1 16 0
OR
'_
--1
•2—Pi CVR
PANIC
M m
V SX AENEL
47 1/4' 41PJc
1920 n
/ B ONI
B
C /
SERIES 3000 (SX—SO) SINGLE SLIDE
EXTERIOR ELEVATION
•S%- 1 EXLEROR IIII
)OR OPENING \
SERIES (S%-SO) SINGLE SLIDE LL
PLAN EMERGENCY
BREAK OUT
1. T
1. tPILA. M.1 SNOMB SIRE RNL AND NUNBN CANONS AVEAM AS DNICASED.
3 22--MML�YA�IL KING WIIH GB6DPMAMG EXCM EREUWEAAN0�P01M LOCKM�M BY NGAVALAOX ON BERES 3NO YP MOM 40NLY ONMSERIB 2000. SEESHOWN:
SNEET 154 N WRN PM'IC OENCE NUNBN.
4. PRODUCT SWNL BE N FA LURED AND INST W ADOCRDANCE M PRODUCT APPHOVAE
5. SEE SHEETS 5, 7, 8 AND D FOR REQUIRED ANCMDRACE
G. SEE SHEET 12 FOR GUONG OETAB.
f
1
S�
TYPE
NOxP4L
N
LIEN
XOWINL
Pug.
NIDM
NOYPYL
Pu4L
.,
CtDDONO
V
K�
B
`a
{e.{
ssA
GA
1 Y SDf
SO I
x w
PIWOE fldGN iWIPW. OIEW
GY610W1
IiIXilf IX4AC' NtN MdWO
NNbWLE
4 n
i a
C
a oe] ees
1 ♦ EDP
�Fk
q
8
PRODUCT RENEWED
GURNA1CM�niN WnPMWn
xoA-xo. tB-0R2t.1t
����
14-1E
uu:
paoouer aevlseo
eAee oesen
v rene.
Xw 17482B,t1
e.Pbenen o.0 04N42018
nA�'T
i
f � I
SERIES 2000
EXTERIOR
ANCHOR
ANCHOR
EDULE, TYP-
ED 5
ER
ATION.
FRAME ANCHORING
N.T.S.
INTERIOR
LADIES
1. SEE TO T 11 FOR
F80TIC RS, 5/I6-1E 10615 WITH WASHtA.
2 SEE SHEEP 11 FOR STACKm BOTTOM PAIL OPTIONS.
5-PT LOCKS
wl"g S�iyS¢Yn
yWem
OW
HO
O
dddG p
o LY
k ` �
N
EXTRUSION, MULTI -PIECE EMBED A
kEMUEO '`EXTRUSION, OPTION 7/4" SHIM SPACEPARTINTERIORXX %%: PART, MULTI-PIKEPARTOPTIONDEDETAIL, OPTIONK 823 96 37AB VERaSEE HEAD ANCHORS SHEET 511
, iv 39 83EAND THRESHOLD ANCHORS 98 99 a a a a a
SHEET 9. THRESHOLD (S%-0)
ANCHORS APPLICABLE ONLY ddddd
Tn 3Ksi mNCRETE. �.;.IJORIZONTAL SECTION
3 2"=1'-0' SINGLE SLIDE PRODUCT RENMED
NOTE: ITEM 58 'FOAM BLOCK' INSTALLED 'aWimx ""L` "� Rei1a" 2
IN ALL STILES, EXCEPT LOCKING STILES. uos-x- t60zxyH
NOT SHOWN IN ALL STILES FOR CLARITY teu.vN,ml.awvanvz3 $�� ��.
14-1E
PRODUCT RINSED U[SCR�V
rrona.
xas.xo. 174820.11
RSL By baWe Wte N10tR
/.NpgLLOWg0tP1HCXOR TPFS p
b ¢i Gnlml O
I
OF
3000
INTERIOR
ANY ANCHOR
PER ANCHOR
SCHEDULE. TYP.
SHEET 5
PER E
ELEVATION. I XI{j
EXTERIOR
p
SHIM
2 1 2 2
4 VERTICAL SECTION
2--1'-O'
Nm
1. J 9 M HIM CONNI=CN FASTENERS: 5/15-19 HHMS WITH WA$HDi.
2. SM SHEEP 11 FCR STALKED 90ROM MR OPRONS.
5-PT LOCKS
HEADER ABOVE,
®: EXTRUSION,
EXTRUSION, N
EXTRUSION, OFTIO
®: PART
®: PART, MULTI -PIKE
®: PART, OPTION
®: DETAIL
DETAIL, OPTION
SEE HEAD ANCHORS SHEET S.
AND THRESHOLD ANCHORS
SHEET 9. THRESHOLD
ANCHORS APPLICABLE ONLY
TO 3KSI CONCRETE
0
NOTE: REM 58 "FOAM
IN ALL SDLES, EXCEPT
NOT SHOWN IN ALL SR
0
SHIM SPACE'
a
erybamnnatn OdOd3518
a r l
I
TYP OF
PANIC
�Vwd .e
w .
0
INTERIOR c c
EXTERIOR ?
cwi o
5 6 20
(SO-5%-SX-SO) SPACE
r
b
0
HORIZONTAL SECTION 16 1
® o
19
0
m
a
2'=1'-0-
BI-PARTING
U
'0
a
S
z0
55
1
39
n
0
®
O-
L
u <
PANIC 5$
0
ANY AN H R®:EXTRUSION
PER ANCHOR
59
m
r\
a
�: EXTRUSION, MULTI- E
REL�`E L 3 W
SCHEDULE, TYP.
SHEET 5
u
m
OPTION
HEADER ABOVE\
INTERIOR
---
a
N
�-®: IXMSION,
r 58
& PER
ELEVATION. PANIC
®: PART
r.
® DEVICE
iv
m m
XX XX : PART, MULTI -PIKE
v d
w
PART, OPTIONS
5
w
DETAIL
a'
TOR SO-
35
E.D. '
2
2 1
2 24
2 DETAIL-. OPTION
0 59 3G
w ]S
.D. •Cj
`..r., � "a 2 1/IT°
_ 4' SHIM SPACE
(SX
2
N 2
1
2 24
0 IZO T L TION <
FRAME
ANCHORING VERTICAL
�:
SECTION
5.
6 2-1,-0- SINGLE E
2'=1'—O'
2°=1'-0'
SEE HEAD ANCHORS SHEET
AND THRESHOLD ANCHORS
NOTE: ITEM 58 'FOAM BLOCK*INvaaoucT aexevreD
r .�u n•ne
v'
SHEET 9. THRESHOLD
ALL STILES, EXCEPT LOCKING STILES. 1 1,
ANCHORS APPLICABLE ONLY
NOT SHOWN IN ALL STILES FOR CIARffY
N ALL wI•odwNu
TO 3KSI CONCRETE
r+w a
a.
eu.,, rcr�e
vaoouer aevlseo
o .w u.nom.
mv`aina�
NOLNa. 1T-UB]&11
e.rN.lm.oWONOb2019
NO1F.
R4HOR9LMmIRP
TD
1. HFAD
CONNECTION FASTD1Di5; 5/om HH45 WITH WASHER
��---
ni..w
2 BE S11 FTM STMXEO BORCN PM OP11015.
BE HEEP
1
DURA-STORM SERIES 2000/3000 THRESHOLDS & ANCHORING
PRODUCT RENMEY
CONCRI
xaowo erao� a 0e .Rn u. R.xm
NERFJR, R'S &RSTO FOR AM14NOR FOR➢ULP A.ID xoA.xd +e-Duf.++ TILE, T1LE, 0
P.pimm� PahON0dl20D 0
(TYPICA
27 m�i.. R u<�mm=i
:XTERIOR INTLRIGR S4 INTERIOR,
THRESHOLD —TAPERED EXT
3'=1'-0' 2000
THRESHOLD —TAPERED
INT2000
13' O.C. MAX
ALONG ROW.
3" 0.TYP
/
PANEL
OVERLAP -
INTERLOCK
CLUSTER
(TYPICAL)
3'
-I TMQ MUMN
W� RFC$ X BE M11 I
THRESHOLD —TAPERED EXT THRESHOLD —TAPERED INT
3'=1'-O' 3000 3'=1'-O' 3000
j�''�� �p�� EXTERIOR
�+ �-I� �I'-I INTERIOR IQNU II /TOP OF
INTERIOR Y � III O II EXTERIOR n TnP nF CONCRET
EXTERIOR
PROOOGTREVISED
im mP°�.°. w.Tmnm
xon.rm. naexem
cvn.u..om Od06201R
tl�
THRESHOLD —TAPERED
3000
3'
I \LOCK S71LE INTERLOCK
THRESHOLD ANCHORING EXT CLUSTER CLUSTER
N.T.S. (APPLICABLE TO 3KSI CONCRETE ONLY)
S mA o EXNRUSION
k CROUT - (RE T __DARE
FILL/ (RECESSED)
THRESHOLD —SQUARE
3'=1'-0' 3000
9
DURA-STORM
MU�7'8 N.T.S. 6e6YT6
ao.09J•
STILE LEAD
NARROW
15 H.T.9. 6063-T6
6 HEAER
X.T.S. 60fi}1B
2000/3000 EXTRUSIONS
-1 1.759• r
T
o.aw• g
1
STILE FIXED
NARROW
11 N.i.S. 606}T6
HL4 N.T.S. 6063- 6
as
0.093•
TOP RAIL, SX
2000
10 n.T.s. e663-Ts
� go,
1
STILE PIVOT
''3 N.T
N.S.AR OW
606AT6
taJs• tass'-�-1� 1.747'
STEEL PANIE
/1 REINFORCINQ
Ifr—1 I A A-36
1.569'F-
s L F
O.OBJ' i C.003' i
1 1 a.ut' � vaas•
0.170' Ls60
16N' PANIC
TOP RAIL, SO TOP RAIL, O MUNTIN CLIP
�(3000� 2000 H� 79 N.L9. 6661.16
7 n.Tz 66eYTe $ x.rs. ea6}Tfi 26 x.ts. ms}Ts
--I IAsO• 1.75o' —i tA50'
0.1W 1 0.125• Min" D 1
STILE LEAD STILE LOCK STILE PIVOT
MEDIU MEDIUM MEDIUM
12 N.T.S. 606YT6 �� H.T3. 6063-T6 �� N.T.S. fi0fiYT6
HEADER (2 PC.)
N.TS. 606}T6
�I.TJS'—i n
0.1M'
GUTTER
�
20 Safi}Tfi
GLASS
19 N.TS. 606]Tfi
s.vov'
1
]� I
z N.T.S. 606}T6
MN
rl
JAMB INSERT
3 X.T3. eas3-n
PROOUOT REREWEO
awu'nr°�'i-1b b. xoaxe 1&0331.111.31
e.9nnNnn P.3. oavaz ozJ
B]
You W Ce,rov
PROOUOT REVISED
Bu0dln91tlm wlb U- NbAJ-
NOA-Nv.0 Q• ,T-0BZE.Tt
nq,s.uon Onb Oa062o1E
tl31am aenL�
n
ts
10
DURA-STORM SERIES 2000/3000 EXTRUSIONS
PRODUCT RENTSEO
y. AIM No R
NOMNoi iT•0828.11
F .em.0.1.001O=Ol8
O
mi.m u on
6.000'
0.100'
N
vzl-
60
zB N.T.S. 6T-T6
B.00D'�
1 o.o9e'
ALTALT T�
29 tl.T.S. 60LD
4.SW
TH�30 N.T.S. 606]-T6
Lone•
KEE
94 nas. STR6P
}�—f-0.120.1x0•
t°ao•J �tsoo'
CK
48 LS. 606J-T6
I,000
0.188
1,000'4---4
N
00 GLE
N.TS. 606}T6
0,09
TOO,
�50.100-
T1 T
0.500'J '
0.,10•
L0.600•
TZ
��0-D.104'
0300•JT
0600•-f
THRESHOLD
95
COMPONENT
33
n THRESHOLD
]�
THRESHNOLD
N.T.S. 606 -T6
N.LS 606} 6
N.TS.
rx.000
--{ I�.Tu'
17 o.osL�� J�1}
MUNTIN BAR
N.TS. 6063-T6
o.oss•
21 $
L 1
BOTTOM RAIL, O
N.T.S. 6061-T6
—{ 1.7m• F--
0,09]'
22
1
BOTTOM RAIL, SX/SO
N.T.S. 606YT6
PRODUCT R8N8W80
w a nm. none.
x°ux.. 18-0ixf.11
Capinelw 0.3.00IOiR020
ie'um
STACKED STACKED
BOTTOM RAIL, O BOTTOM RAIL, 0
N.T.S. 606J-T6 N.TS. 606}T6
MIN. OF (2)
3/I6• Pop RMETS
0 z2' O.O. MP]I
D141'
23
i
(SENES S000)
BOTTOM RAIL, O
N,TS. DPI 606YT6
STACKED STACKED
BOTTOM RAIL, SX/SO BOTTOM RAIL, SX/SO
N.T.S. 061T6 N.T.S. 606}T6
_*
o0
do
0.141'
0
_
N o
k
g g
� `
N
E i
1s6mFs:0oo)
BOTTOM
RAIL,
Ors.-
o
N.T.S.
1-PIECE
6063-T6
—i
MIN. OF (2)EtiS.
IB_ POP RN
AW
3 D.C. 4nx
-A
0.141'g--a
I
a --
�
8424ds!4
2S
pgpg
��
1448!
,s6u6s
xw9n000)
BOTTOM
RAIL,
SX/SO
N.T.S.
2-P=
606}T6
Jj
DURA-STORM SERIES 2000/3000 DETAILS
34
97
SO PANEL
BALL
A VO 0 P D E TO
MS SERIES 3000 Nis SRPS =
1 HOLD 97
SO PANEL
BALL DETENT
Q BOTTOM �
OSX GUIDE,/PIVOT BOTTOM
C *97
ES 3000
pO PANEL
�1SECURITY HOOK
U Nis SERIES 3000
(SX-so INTERLOCK)
11I�I�F':
r
3-POINT
LATCH DETAI
N NTS IMES 4000/30W
D S PIVOT TOP
NIS
ME j�
�Jill
1 G PANIC BOLT TOP
Nis 3000
r-=jSjL BOLT TOP
Nis SDHS 1C01730U
�1OMUNTIN DETAIL
wS mmc sacoo/m
nNTS PA IC REINF0 C3oG 55
PANIC
DO
n ANIC BOL BOTTOM V MUNI DETAIL
MS 3000
N S 3000
PROOUC RENEWED
o i,g 1
xoFNe. 1&OUL11
9.e.V-. o.b0Y04Q02J
PRODUCT REVISED
.nwr,ne.xu u. monm
Rr /i w
NntFe NIa m neonw,
N: No �o
xos�x.. 17-0828.11
1. ,TEN 74, ^SIETL PUTS-PM9G REINFORCING'. 5 CONTNNM WRMN VERRCN. SILL£, HIS A
Ea.b.um 4201e
MINNUU OHM OF 48. AND S CENTERED xflDKA1LY ABOUT CFNTERUNE OF HORIZONTAL
oAwe
MUNMI. R 74 M FAST M AS ,OLLOWS: SINGLE ROW #10 X M X 1/2- iHTCUS D e' OC.
1 /4'
a017' aATm 81POTE I
NEgA,ER PER aJRW 1
1/4' ANI
91 3M GLAZING TAPE
FULL LENGRI
zD
SEDING
EXT.BLOCK
(MIN 70
SHORE A
92 DUROMEIER)
0
0
1/4-
COOT SF-aAS4 NUtk
PER alim N
1/4- ANN
91 3M GLAZING TAPE -
FULL LENG�
20
SBLNG
OCK
f7(F. BLOCK
(MIN 70
_ SHORE A
INT.
#10 FH
W
SCREWS
S018'CRE
D.G.
!�(�
1 9
IEI`OGE 90
f G
19
k
INT.
p10 FHCREWS'
il'o-
sate•
D.C.
'
-9/16" LAMINATED
GLAZING DETAILS
NTS
JIW3/4'
SMS HEADER
05.8' O.C.
114.fas
M MS, Y'
FROM ENDS
10
OWOPOINT
0 0 ANEL ANGLE
NTS S
0 PANEL
4';;o
ASTEN W/ 81OX3/4 PH I.S. 14-185
(4) To BOTTOM RAIL, (3) TO 49
RESHOLD
TNR6HOLD SK PANEL `oc�rnro"o
:l0-PANEL BRACKET K SX GU E PIVOT BOTTOM ^
Nis SERIES 2000 L�JSJ
`J NIS SERIES 2000 (0-SX INTERLOCK)
DURASTORM SERIES 2000/3000 LOCKING ARRANGEMENTS
ADAMS RITE 4016 AMS RITE 1870 ADAMS RITE 4016
B T 9B 99 515 HEADER BOLT HEADER BOL 9B 99
"4
ryry:
LAD RITE 53 ADAMS RITE 1870 ADAMS RITE 53
5-050 SERIES, CYLINDER MS1850S-050ADAMS RITE DEADBOLT OPERATED FLUSH BOLT SERIES HOOKBOLT
4015 552THRESHOLD
BOLTFINISHED (ACT.)37 39FLOOR
ADAMS RITE 4015 FINISHED
THRESHOLD BOLT
3—PT CONCEALED FLOOR
0 KICGSYSTEM 3739 -PT3_CONCEALED
SERIES 2000/3000 LOCKING SYSTEM
SINGLE SLIDE SERIES 2000/3000
81—PARTNG
J MR.-
. mmll
I"1. :ry R.
191
40 55 MUNTIN
S
G86 SERIES
DEVICE WITH 2—PT
VERTCAL ROD
FINISHED
FLOOR
4—PF CONCEALED
VERTICAL ROD WITH
PANIC RELEASE
LOCKING SYSTEM
SERIES 3000
BI—PARTING
9:IIY-'1�f4Qe
r
#100/4' SMS
®5.5" O.C.
#14xl.25' PH SDS,
2' FROM ENDS &
FASLEN
$100/4 PH I
(4) TO BOl
10,
PROPU"y RENMED
e.m1221.11"
�
14-185
PROV IJ" REUIISW
xoAr�a 174828.11
E.vxnuan Pmn O4NQ2o1e
a>
YLw
,fjl
LJ