APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS: 6 6 5- JR-D
125 L , Icc
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
TP6 %ZoorWli /11,4AlvF,4C7- ufLk�L
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: O y / 9 Z ST. LUCIE CO CERT. #:
BUSINESS NAME: Gi+E /-SN C'oH3 �R Uci /o.y
QUALIFIERS NAME: X-r- G i r� LS'/l
ADDRESS: 3 to 1/5 t,. , / Gn-tc/z T3 L V.0 S 7 .E / 6 /
CITY: /I FL /3 Oc- PAN.j5 STATE: F L ZIP: 3 Z9 3 y
PHONE (DAYTIME): 3 Z I- qZ 7- je U tZ FAX:
OWNER/BUILDER INFORMATION:
NAME: F4 fLiz E LL 4 P) v 4- /J /�/� 4.c
t ?T/�R Al
CITY: t/SL
PHONE (DAYTIME:
STATE: r L
FAX:
ARCMTECT/ENGINEER INFORMATION:
S' J 61Z�4,C
ZIP:
NAME:
- -- _ ADDRESS:
CITY:
STATE:
ZIP:
PHONE (DAYTIME):
FAX:
Nana
SLCCC: 9123109
wmm
Revised 06130/17
Tl:- <1'1 I T -9 /7/z oo c '?
Forensic Engineering Consultants, Inc.
MEMBRANE ATTACHMENT CALCULATIONS
Project Name Farrell Storage Facility Report No.: LWR-MB-18.004
Project Address SW Quad. of Kitterman Road & US Hwy-1
Port St. Lucie, FL
Deck Substrate ' Steel Insulated Mean Roof Height 47.0 Feet
Configuration Low Slope Roof Area (Approx.) 19716 Sq.Ft.
Category II Roof Width 124.0 Feet
Exposure Condition C Perimeter Width 12.4 Feet
Building Type Enclosed Parapet Height 2.5 Feet
Base Wind Speed 170 mph Corner Zones 12.4' x 12.4' Each
Slope V 0.0 Slope H 12.0 Slope Angle° 0.00
Uplift Pressures q: = 0.00256 K� Kn Kd V2 P = q, (GCP - GCP;)
qz K. Kt Kd V GCP GCPI
68.233 1.080 1.005 0.85 170 -1.00 0.18 Field
-1.80 0.18 Perimeter
-2.80 0.18 Comer
Field P1 A -80.51 psf P1 asd -48.31 psf
Perimeter P20.-135.10 psf P2asd -81.06 psf
Corner P3 un.-203.33 psf P3 asd-122.00 psf
Proposed System Firestone UltraPly TPO Single Ply Roof Systems over Steel Decks
Product Approval No. 17-0727.01 (Page 79 of 104)
System Design Pressure -52.5 psf
Membrane Full Width 120 inches Side Lap 6 inches Net Width 114 inches
Membrane Red. Width 63 inches Side Lap 6 inches Net Width 57 inches
Membrane Red. Width 60 inches Side Lap 6 inches Net Width 54 inches
Fasteners Firestone Heavy Duty Fasteners and Firestone HD Seam Plates
Fastener Spacing in Lap of Membrane 6 inches # Rows 1
Min. Characteristic Resistance Force-249.38 Ibf Verify with TAS-105 Tests
Fastener Spacing {(MCRF/Pi) x 144}/Row Spacing
Full Width Mmbrn Reduced Width Addl. Reduced Width
Field Fastener Spacing 6.52 13.04 13.77"'�
Perimeter Fastener Spacing 3.89 7.77 8.20 "
Corner Fastener Spacing 2.58 5.16 5.45 -
RECOMMENDED MEMBRANE ATTACHMENT PATTERN
Field Laps @ 114" o.c. Full Width Sheet 6 inches on center
Perimeter Laps @ 57" o.c. Reduced Width Sheet ..6-inches on center
Corner Laps @ 57" o.c. Reduced Width Sheet 5 inches on center '.
These calculations have been done in accordance with ASCE 7-10, based on the information provi = _
contractor. The roof system must be installed in accordance with the FBC &manufacturer's recom nd 5:
We recommend TAS-105 tests to verify that above MCRF may be realized, before installing new rc =4'
t i�Y
Sincerely
Fore is Engineering Consultants, Inc.
R. N. Sai ppan, P.E.
Principal Engineer
Florida Registration No. 46696
Forensic Engineering Consultants, -Inc. (CA # 8265). P.O. Box 970034, Boca Raton, FL - 33497 Ph (561) 9018490 Fax (561) 218 3830
BRYNTESEWSTRUCTURAL ENGINEERS
[ACCEPTED
0 ACCEPTED AS NOTED
Ej IJOT ACCEPTED, REVISE AND. RESUBUT
❑ RECEIVED
REVIE'VV AND ACCEPTANCE IS FOR DESIGN WTENT ONLY AND IS
NOT FOR DIMENSIONS. QUANTITIES, OR FIELD CONDITIONS,
WHICH ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
NO OOCUh^E TSE pRORDEVIATIONS NTRACT
ACCEPTED UNLESS FROM THE
IS
COCLEARLY
IDENTIFIED AS SUCH AND EACH IS SPECIFICALLY ACCEPTED OR
REJECTED. ANY ACCEPTED CHANGE OR DEVIATION IS SUBJECT
TO A REDUCTION OF THE CONTRACT LUMP SUM.
Reviewed By Date
lam/
REVIE-VVE® FOR
CODCOMPLIANCF-
ST. UCIE COUNTY
EOCC
• �r : iC Q �. 3
'Firestone
Interim INSPECTION REPORT
BUILDING PRODUCTS FINAL INSPECTION REQUIRED
Inspection Date: 5/9/2019
Building Name: Farrell Advantage Storage
Building Address: 605 Kitterman Rd. Port Saint Lucie, FL
Contractor: L & W Roof Systems, Inc.
Technical Representative: Kurth, Gary
There were no attendees for this visit.
Roof Accessibility: Roof Hatch
Weather during Inspection: Clear
Roof Visibility during Inspection: Clear
Membrane Type: TPO
Insulation: N/A
Project No: 3357486
License/Registration No: 40007129
System Type: Mechanically Attached
Additional Repair Comments: —
field was down and flashing. Waiting for metal,checked seams and details they all appears to meet Firestone
specifications
Overview of Roof Plot
=irestone Building Products inspections are for the sole use of Firestone and are prepared for the sole purpose of verifying the warrantability of the
=firestone roof system. The inspections do not assure conformance to building owner's specifications, building codes, insurance requirements or any
ether construction requirement.