Loading...
HomeMy WebLinkAboutGFA PAPERSSince 1988 Florida's Leading Engineering Source Environmental •Geotechnical • Construction Materials Testing • Threshold and Special Inspections • Plan Review & Code Compliance April 19, 2018 Mr. Dean Doyle SCANNED Doyle Masonry Properties LLC By P:O Box 12339 St. Lucie County Fort Pierce, Florida 34979 RE: Report of Preliminary Soil Exploration Proposed Commercial Structure Lot 8 - Industrial 27" Street Fort Pierce, Florida GFA Project No. 18-5500.00 Dear Mr. Doyle: GFA International, Inc. (GFA).perforrned three (3) auger borings with hand. cone penetrometer testing at the 'above referenced project. site. The locations of the borings are shown on the attached Test Location Plan. The subsurface exploration activities were -performed in accordance with Chapter 18 of the Florida -Building Code (latest edition) and applicable ASTM standards. Detailed information for the subsurface conditions encountered in the borings are contained on the attached auger boring logs. Based on the test results, the soil on which the referenced structure is to rest is capable of providing a safe bearing capacity of 2,500 psf subject to the limitations noted. herein.. We recommend that the bottom of the footings bear at a depth of at least 12 inches, below finish grade. The depth shall be measured from the lowest adjacent grade. We also recommend •a minimum footing width of 18. inches for spread footings and 16 inches for monolithic footings, but not less than 8 inches more than the width of the imposed wall. This report does not state or imply that the foundation soilsat the bearing level will remain in the original condition in which they were found during the subsurface exploration activities. Exposure to the environment may weaken the foundation soils at the bearing level if the foundation excavations remain open for an extended period of time or if the foundation soils are exposed to rainfall. Consequently, it is recommended that the excavations for the wall'and column footings be performed to final grade'and foundation concrete be placed as soon as practicable to reduce the. potential for deterioration of the bearing soils. The geology of the site as mapped on the USDA Soil Survey website consists of Lawnwood and Myakka sands (21) and Waveland-Lawnwood complex, depressional::(51). These are sandy soils and organic soils are not indicated. In addition, no unsuitable bearing materials were observed in the boreholes, and -only normal site preparation. should be required for construction. It is recommended that the 2 feet of soils below existing grade, below the bottom of all new footing excavations and slabs, and all fill material be compacted to at least 95 percent of modified Proctor (ASTM D 1557) maximum dry density prior to placement of concrete. 607 NW Commodity Cove • Port St. Lucie, Florida 34986. a (772).924.3575 (772) 924.3580 (fax) • wwmi.teamgfa.com ' OFFICES THR006H0UT FLORIDA - Proposed Commercial Structure Lot 8 — Industrial,276 Street, Fort Pierce, Florida GFA Project No. 18-5500.00 April 19, 2018 Page 2 The preliminary recommendations provided herein are based upon the above considerations. If the project information stated in this report changes, please inform GFA so that we may review our recommendations with respect to the modifications. Additional borings and explorations are recommended after the final location,and design of the structure have been established to verify the uniformity of the subsurface conditions at the property. The results of the supplemental geotechnical exploration and recommendations will be provided in a final report. We appreciate the opportunity to be of service to you on this project and look forward to a continued association. Please contact the undersigned if you have any questions or comments, or if we may further assist you as your plans proceed. 9oaa $ertl bf'quthofzation No. 4930 o. 83218 Kent, P.E. : LU S&*10roiegttln46ieer_. iT@gt'Lbbation Plan Auger Boring Logs (3) Notes, Related to Test Borings ii, gn Colliec Manager Distribution: Mr. Dean Doyle — Doyle Masonry Properties LLC 1 pdf FP Test Location Plan: Lot 8, Industrial 27w Street, Fort Pierce, FL f I NZ m � I 'PROPOSED SITE DATA Cd® .0 w ,• LOCHaON MAI' GENERAL NOTES •w� H m.. E'er,` .o IM "..&T.o" ®..,......CSC Approximate Auger Boring (AB) Locations w r PARKING. DATA w ma rE PLAN 'ROPERTIES. LLC ------------------- I I i I I I I l I I 1 W7 I I I I I I r -In.0 usu Since1986 Florida's Leading Engineering Source AUGER BORING LOGS WITH HAND CONE PENETROMETER,(HCP) TESTS Client: Doyle Masonry Properties LLC Project: Lot 8 - Industrial 27'" Street Fort Pierce, FL Elevation: Existing Grade Project No: Lab No: Test Date: Technician: 18-5500.00 4/16/2018 MM/JB TEST LOCATION: AB —1 N27.488931 ° W80.3513780 HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0-2 Gray fine sand SP 1 80+ 2-6 Light gray fine sand SP 2 80+ 6-7 Dark gray fine sand, trace silt SP 3 60 7-10 Brown fine sand, little silt and clay SP-SC) 4 60 5 80+ 6 80+ 7 80+ 8 80+ 9 80+ 10 80+ Water table at 6.7 feet below ground surface. TEST LOCATION: AB — 2 N27.488960 W80.351270 HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0-2 Gray fine sand SP 1 60 2-5 Light gray fine sand SP 2 60 . 5-8 Dark gray fine sand SP 3 80+ 8-9 Dark brown fine sand, trace silt SP . 4 80+ 9-10 Brown fine sand, some clay SC 5 . 80+ 6 60 7 80+ 8 80+ 9 80+ 10 80+: Water table at 7.2 feet below ground surface Florida's Leading Engineering Source AUGER BORING LOGS WITH HAND CONE PENETROMETER (HCP) TESTS Client: Doyle Masonry Properties LLC Project No: 18-5500.00 Project: Lot 8 - Industrial 27" Street Lab No: Fort Pierce, FL Test Date: 4/16/2018 Elevation: Existing Grade Technician: MM/JB TEST LOCATION: AB-3 N27.488990 W80.351220 HCP. Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0-1 Gray fine sand SP 1 50 1 - 5.5 Light gray fine sand SP 2 80+ 5.5 - 7 Dark gray fine sand, some silt SM 3 80+ 7 - 10 Brown fine sand, trace cla SP 4 70 5 80+ 6 80+ 7 80+ 8 80+ 9 80+ 10 80+ Water -table at 7.1 feet below ground surface NOTES RELATED TO RECORDS OF TEST BORING AND GENERALIZED SUBSURFACE PROFILE 1. Groundwater level was encountered and recorded (if shown) following the completion of the soil test boring on the date indicated. Fluctuations in groundwater levels are common; consult report text for a discussion. 2. The boring location was identified in the field by offsetting from existing reference marks and using a cloth tape and survey wheel. 3. The borehole was backfilled to site grade following boring completion,,and patched with asphalt cold patch mix when pavement was encountered. 4. The Record of Test Boring represents our interpretation of field conditions based on engineering examination of the soil samples. 5. The Record of Test Boring is subject to the limitations, conclusions and recommendations presented in the Report text. 6. "Field Test Data" shown on the Record of Test Boring indicated as 11/6 refers to the Standard Penetration Test (SPT) and means I 1 hammer blows drove the sampler 6 inches. SPT uses a 140-pound hammer falling 30 inches. 7. The N-value from the SPT is the sum of the hammer blows required to drive the sampler the second and third 6- inch increments. 8. The soil/rock strata interfaces shown on the Records of Test Boring are approximate and may vary from those shown. The soil/rock conditions shown on the Records of Test Boring refer to conditions at the specific location tested; soil/rock conditions may vary between test locations. 9. Relative density for sands/gravels and consistency for silts/clays are described as follows: SPT CPT SANDS/GRAVELS SPT CPT - SILTS/CLAYS BLOWS/FOOT KG/CM RELATIVE DENSITY BLOWS/FOOT KG/CM2 CONSISTENCY 0-4 0-16 Very loose - 0-1 0-3 . Very soft 5-10 17-40 Loose 2-4 4-6 Soft 11-30 41-120 Medium Dense 5-8 7-12 - Finn 31-50 121-200 Dense 9-15 13-25 Stiff -50+ over 200 Very Dense 16-30 25-50 Very stiff >30 >50 Hard 10. Grain size descriptions are as follows: NAME SIZE LIMITS Boulder 12 Inches or more Cobbles - - 3 to 12Inches _ Coarse Grovel '/.to 3 Inches Fine Gravel No. 4 sieve to '/. inch. Coarse Sand No. 10 to No. 4 sieve " _Medium Sand - - No: 40 to No. 10 sieve Fine Sand _ No. 200 to No. 40 sieve Fines Smaller than No. 200 sieve 11. Definitions related to adjectives used in soil/rock descriptions: PROPORTION ADJECTIVE APPROXIMATEROOT DIAMETER- ADJECTIVE <5% Trace " . Less than 1132" - Fine roots 5%to 12% Little 1/32" to - Small roots 12%to 30%. _ Some %I'to 1" Medium roots 30% to 50% And - Greater than V Large roots Organic Soils: Soils containing vegetable tissue in various stages of decomposition that has a fibrous to amorphous texture, usually a dark brown to black color, and an organic odor. Organic Content <25%: Slightly to Highly Organic; 25% to 75%: Muck; >75%: Peat GfH IgIa-oo Soil Nuclear Gauge client: Project: Go, Report Date: 7/18/2018 Doyle Masonry, Inc. 17-6476.00/a Test Method: ASTM D 6938 P.O. Box 12339 Doyle Masonry, Inc. 2017-2018 (tern, 18 Z�lg Part St Wei° Fort Pierce, FL 34979-2339 Agreement St yttl) Various Locations FBPE CA 04930 COUP 607 Nw commodity Cove FL Pod St. Lude, FL 34986 1). Phona:772-924-35751 Far. 772-924-3580 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture. Dry Density Depth Percent Comp. Test# Of Date ProctorlD Method Classification % (p %) (p in Compaction o Remark 12 7/17/18 8188 D1557 WA 13A 100.3 9.2 96.9 12 97 95/105 Pass 13 7/17/18 8188 D1557 N/A 13.4 100.3 8.6 95.8 12 96 95/105 Pass 14 7/17/18 8188 D1557 NIA 13.4 100.3 9.5 96.1 12 96 95/105 Pass 15 7/17118 8188 D1557 'NIA 13.4 100.3 8.1 96.8 12 97 95/105 Pass 16 7/17/18 8188 D1557 NIA 13.4 100.3 8.0 97.2 12 97 95/105 Pass 17 7/17118 1 8188 D1557 NIA 13.4 1 100.3 1 8.2 1 98.4 12 98- 95 / 105 Pass Test Information Gauge Test # Test Location Elevation Reference Make / Model I SN / Calibrated Field Technician 12 Below Bottom of Fooling: 3100 Industrial 27 St., Ft Pierce, 60' x 100' Building, SE 0-1' -Humboldt / 5001 SD 19086 / Liveonan, Robert Comer, 13 Below Bottom of Footing:.3100 Industrial 27 St., Ft Pierce, 60' x 100' Building, South 0-1' Humboldt 15001 SO / 9086 / Livehnan, Robert side center 14 Below Bottom of Fooling: 3100 Industrial 27 St., Ft Pierce, 60' x 100' Building, SW 0.1' Humboldt /5001SD / 9086 / Livennan, Robert Comer 15 Below Bottom of Footing: 3100 Industrial 27 St., Ft Pierce, 60' x 100' Building, NW 0-1' Humboldt / 5001SD 190861 Liverman, Robert Comer 16 Below Bottom of Footing: 3100 Industrial 27 St., Ft Pierce, 60'x 100' Building, North 0-1' Humboldt / 5001SD / 9086 / Livennan, Robert side center 17 Below Bottom of Footing: 3100 Industrial 27 St., Ft Pierce, 60' x 100' Building, NE 0.1' Humboldt / 5001 SD / 90861 Livennan, Robert Comer - Remarks Corr AA//�7�/ v Pass: Tests results comply with specifications Tests am "Direct Transmission' Method A) unless probe depth Is noted aslK[ 'Backscatter'. Gauge calibration data on file With the testing agency. �� ,Q -. • • • • • ., 12, 13, 14, 15, 16, 17: 1-2 HCP=Slit, > 95 %Compaction, PASS. %CENSF' •.,, HCP tests are empirically correlated tote relative density of the oil .. 1I liampay W1 U01 PZY •r,rlrnn•" Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 r 607 NW Conimodity Cove •. Port St. L:m_-, Laboratory Compaction Characteristics of Soil Using Modified Effort ASTM D 1557 ve All I81018 c lhl�eae- Project: 3100 Industrial 26th Street, Fort Pierce Project ID: 17-6476.06 . . Address: 310.0 Industrial 26th Street, Fart Pierce Report ID: 8188 Client: Doyle Masonry, Inc. Soil Location: Building pad, .. Sampled By: R Liverman Date Sampled: 7/17/2018 Tested By: R Robinson Date Tested: 7/18/2018' Soil Description: Light.gray fine sand Test Method Used: - Preparation Method Used: Dry Type of Rammer. Mechanical As -received Water Content: N/A Comments: 105 104 103 LL u 102 IL w 101 Z w 0 100 13 m 97 8 9 10 11 12 13 14 15 16 MOISTURE % Dry Density (p"cf) .''Moisture.(%) g :. 10.7 100.0. 12.1 100.3 _ 13.4' 99.8 14.7 Maximum Dry Density (pcf) 100.3 Optimum Moisture (%) 13.4 0,6321 ' — 7/18/18 rt tent, P . ' : , _ Test report shall not be reproduced, except in full, without the written approval of GFA International Environmental'•'Geotec_hnical a Construction Materials Testing •Special& Threshold Inspectid'ir5/; ie &%ode Compliance .Florida's Leading.Engineering Source 1 I 1 t) . www.tearngfa:oom