HomeMy WebLinkAboutFIELD WITHDRAWAL RESISITANCE TEST RESULTSSCANNED TESTING APPLICATION STANDARD (TAS) No.105-11
BY APPENDIX TAS 105-A
St. Lucie County FIELD WITHDRAWAL RESISTANCE TEST RESULTS
GENERAL INFORMATION:
Job Name: St. Lucie County - Road and Bridge Traffic Division Building
Job Address: 3071 Oleander Avenue
Ft. Pierce, FL 34982
Job Site Contact: Thenna Seal Roof Systems, LLC (561) 223-2096
TESTING AGENCY/EQUIPMENT INFORMATION:
Note: The undersigned acknowledges that all testing has been conducted and RECEIVED
results have been reported in compliance with TAS 105 Appendix T105-A
Testing Agency: Cleary Inspection Services, Inc. FEB 2 6 2918
Address: 1017 North "H" Street ST. Lucie County, Permitting
Lake Worth, FL 33460 -
Telephone: (561) 722 - 9881
Fax: (561) 582 - 8039
Email: clearyinspections@kcwand.com
Representative Name: Katherine I. Cleary
Title: Inspector
Test Apparatus: COMTEN MODEL # DFG2W2000, SERIAL # 20606019
BUILDING/ROOF SYSTEM INFORMATION: Main Roof
Approx.
Roof Area Height:
Height: =
15 ft.
Roof Area Dimensions:
Length: =
132 ft.
Second largest dim.: =
41 ft.
Total roof area: =
5130 ft
Perimeter width: =
4.1 ft.
Perimeter area: =
1238.2 ft.2
Corner area: =
113.2 ft.2
Parapet Height: =
N/A ft.
BUILDING/ROOF SYSTEM INFORMATION: Front Entrance
Approx.
Roof Area Height:
Height: =
15 ft.
Roof Area Dimensions:
Length: =
132 ft.
Second largest dim.: =
8 ft.
Total roof area: =
1056 ft.2
Perimeter width: =
3 ft.
Perimeter area: =
768 ft.2
Corner area: =
36 ft.'
Parapet Height: =
N/A ft.
St. Lucie County - Road and Bridge Traffic Division Building
3071 Oleander Avenue
Ft. Pierce, FL 34982
FASTENER INSTALLATION INFORMATION:
Is the fastener a self driller?
Tool:
Fastener type:
Fastener Manufacturer:
Cleary Inspection Service, Inc.
Tel. (561) 722-9881, Fax (561) 582-8039
Email: clearyinspections@kcwand.com
Yes
Hammer
Annular Ring Shank Nail
TEST INFORMATION: MAIN ROOF
Test Date: 2/15/2018
Number of Test Conducted 10
*Note the Location of all tests on 'Building Information', attached.
FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET
Deck:* See TAS 105-11 to determine number of tests Wood
MAIN ROOF
SAMPLE NO.
PLAN IDENTIFIER
INITIAL FAILURE
LOAD
FIELD
PERIMETER
CORNER
1
TI
100
X
2
T2
125
X
3
T3
105
X
4
T4
110
X
5
T5
105
X
6
T6
110
X
7
T7
115
X
8
T8
120
X
9
T9
125
X
10
T10
115
X
STATISTICAL ANALYSIS: MAIN ROOF
No. of Tests
T Estimator
Mean Failure Load:
Sample Standard Deviation:
Minimum -Characteristic Resistance Force:
n=
10
t' =
2.262
F=
113 lbf
SF=
8.13 lbf
F'=
107.181bf
TEST INFORMATION: Front Entrance
Test Date:
Number of Test Conducted _
*Note the Location of all tests on 'Building Information', attached.
FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET
Deck:* See TAS 105-11 to determine number of tests
2/15/2018
0
Wood
2
St. Lucie County - Road and Bridge Traffic Division Building
3071 Oleander Avenue
Ft. Pierce, FL 34982
Cleary Inspection Service, Inc.
Tel. (561) 722-9881, Fax (561) 582-8039
Email: clearyinspections@kcwand.com
FRONT ENTRANCE
SAMPLE NO.
PLAN IDENTIFIER
INITIAL FAILURE
LOAD
FIELD
PERIMETER
CORNER
1
TI
105
X
2
T2
125
X
3
T3
120
X
4
T4
115
X
STATISTICAL ANALYSIS: FRONT ENTRANCE
No. of Tests
T Estimator
Mean Failure Load:
Sample Standard Deviation:
Minimum -Characteristic Resistance Force:
Sincerely,
Cleary Inspections Service, Inc.
e 'ne I eary
Miami -Dade Lab Certification No. 16.0211.02
n=
4
P =
3.182
F=
116.25 Ibf
SF=
7.4 Ibf
F'=
104.47lbf
' N 2�2t[1f3
R.N. Sailappan, P.E.
Florida Registration No. 46696 -
9
Cleary Inspection Service, Inc.
Telephone (561) 722-9881
Fax (561) 582-8039
Email: kc@kcwand.com
Notes:
1. Use of the results herein to determine the required number of
fasteners for insulation attachment or an acceptable anchor or base
sheet fastener spacing, as outlined in TAS 117, shall utilize the
minimum characteristic resistance for (F') determined in compliance
with Section 9 of TAS 105. No margin of safety shall be applied to
field withdrawal resistance test results determined in compliance with
TAS 105.
2. A safety factor of 2 to 1 shall be applied to all results of laboratory
testing.
3. The following pages shall be completed for each roof area and
included with all Field Withdrawal Resistance Test Recording Sheets.
Roof Area Building and Parapet Heights.
(If no parapet exists. "N/A")
N/A
15'
Ground
Level
Page 4
1
41'
8'
38'
Cleary Inspection Service, Inc.
Tel. (561) 722-988, Fax (561) 582-8039
Email: clearyinspections@kcwand.com
St. Lucie County
Road and gHdge'Traffic Building
3071 0leanderAvenue
Fort Pierce, FL
Test Date; 2/15%2018
132'
NOT DRAWN TO SCALE
Drawings & measurements are approximate representation of Feld layout
Page 5
38'
8'
tom.:, L,•x:.
CERTIFICATE OF CALIBRATION
TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
AND PERFORMED IN ACCORDANCE WITH IS010012-2003
THIS DEVICE IS CERTIFIED TO BE WITHIN +1- 0.5% OF FULL SCALE READING AT EACH TEST POINT AT
THE TIME OF SHIPMENT
CERTIFICATE NUMBER: 24859
CALIBRATION DATE: 1/23/2018
PART AND CUSTOMER INFORMATION
MODEL#: DFG2NI2000
SERIAL#: 20606019
CUSTOMER: CLEARY INSPECTION SERVICE INC.
CUSTOMER#: CLE33460
CALIBRATION DATA
APPLIED EXPECTED
FULL
VALUE VALUE I
RUN
AVERAGE
SCALE
(LB) (LB) j
(LB)
(LB)
ERROR
0.00 -0.00 I
0.000
0.000
0.000%
100.00
400.00 400.00
I 402.00D
402.000
0.100%
600.00
800.00 800.00
804.000
804.000
0.200%
1000.00
1200.00 1200.00
1 1197.000
1197.000
-0.150%
1400.00
j
1600.00 1600.00
1599.000
1599.000
-0.050%
1800.00
j
2000.00 2000.00 j
2004.000
2004.000
0.200%
CALIBRATION EQUIPMENT USED
SERIAL #1: 11706016
SERIAL #2:
CAL EQUIP: COMTEN INDUSTRIES load cell CNR EA, S/N I
CNR EA 11706016 was calibrated at ComTen Industries
following to ASTM E-74. The uncertainty is 2
CAL DATE: Lbf. Report No: 20300
6112/2017
I
j
THIS EQUIPMENT IS CERTIFIED TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. I
CONDITIONS
TEMPERATURE 70`F
RELATIVE HUMIDITY: 31 %
AS FOUND NOTES: (' Indicates that the part was out of tolerance)
VALIDATION
v ` Y
CALIBRATION f CERTIFIED
PERFORMED
BY: CC U�TR
r �Y
Calibration not valid without CERTIFIED stamp and initials
6405-49th Street North, Pinellas Park, FL 33781-5724 * 727-520-1200 * FAX 727-520-0299
E-Mail: sales@com-ten.com * Web: www.com-ten.com