HomeMy WebLinkAboutFIELD WITHDRAWAL RESISITANCE TEST RESULTSSCANNED TESTING APPLICATION STANDARD (TAS) No.105-11 BY APPENDIX TAS 105-A St. Lucie County FIELD WITHDRAWAL RESISTANCE TEST RESULTS GENERAL INFORMATION: Job Name: St. Lucie County - Road and Bridge Traffic Division Building Job Address: 3071 Oleander Avenue Ft. Pierce, FL 34982 Job Site Contact: Thenna Seal Roof Systems, LLC (561) 223-2096 TESTING AGENCY/EQUIPMENT INFORMATION: Note: The undersigned acknowledges that all testing has been conducted and RECEIVED results have been reported in compliance with TAS 105 Appendix T105-A Testing Agency: Cleary Inspection Services, Inc. FEB 2 6 2918 Address: 1017 North "H" Street ST. Lucie County, Permitting Lake Worth, FL 33460 - Telephone: (561) 722 - 9881 Fax: (561) 582 - 8039 Email: clearyinspections@kcwand.com Representative Name: Katherine I. Cleary Title: Inspector Test Apparatus: COMTEN MODEL # DFG2W2000, SERIAL # 20606019 BUILDING/ROOF SYSTEM INFORMATION: Main Roof Approx. Roof Area Height: Height: = 15 ft. Roof Area Dimensions: Length: = 132 ft. Second largest dim.: = 41 ft. Total roof area: = 5130 ft Perimeter width: = 4.1 ft. Perimeter area: = 1238.2 ft.2 Corner area: = 113.2 ft.2 Parapet Height: = N/A ft. BUILDING/ROOF SYSTEM INFORMATION: Front Entrance Approx. Roof Area Height: Height: = 15 ft. Roof Area Dimensions: Length: = 132 ft. Second largest dim.: = 8 ft. Total roof area: = 1056 ft.2 Perimeter width: = 3 ft. Perimeter area: = 768 ft.2 Corner area: = 36 ft.' Parapet Height: = N/A ft. St. Lucie County - Road and Bridge Traffic Division Building 3071 Oleander Avenue Ft. Pierce, FL 34982 FASTENER INSTALLATION INFORMATION: Is the fastener a self driller? Tool: Fastener type: Fastener Manufacturer: Cleary Inspection Service, Inc. Tel. (561) 722-9881, Fax (561) 582-8039 Email: clearyinspections@kcwand.com Yes Hammer Annular Ring Shank Nail TEST INFORMATION: MAIN ROOF Test Date: 2/15/2018 Number of Test Conducted 10 *Note the Location of all tests on 'Building Information', attached. FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Deck:* See TAS 105-11 to determine number of tests Wood MAIN ROOF SAMPLE NO. PLAN IDENTIFIER INITIAL FAILURE LOAD FIELD PERIMETER CORNER 1 TI 100 X 2 T2 125 X 3 T3 105 X 4 T4 110 X 5 T5 105 X 6 T6 110 X 7 T7 115 X 8 T8 120 X 9 T9 125 X 10 T10 115 X STATISTICAL ANALYSIS: MAIN ROOF No. of Tests T Estimator Mean Failure Load: Sample Standard Deviation: Minimum -Characteristic Resistance Force: n= 10 t' = 2.262 F= 113 lbf SF= 8.13 lbf F'= 107.181bf TEST INFORMATION: Front Entrance Test Date: Number of Test Conducted _ *Note the Location of all tests on 'Building Information', attached. FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Deck:* See TAS 105-11 to determine number of tests 2/15/2018 0 Wood 2 St. Lucie County - Road and Bridge Traffic Division Building 3071 Oleander Avenue Ft. Pierce, FL 34982 Cleary Inspection Service, Inc. Tel. (561) 722-9881, Fax (561) 582-8039 Email: clearyinspections@kcwand.com FRONT ENTRANCE SAMPLE NO. PLAN IDENTIFIER INITIAL FAILURE LOAD FIELD PERIMETER CORNER 1 TI 105 X 2 T2 125 X 3 T3 120 X 4 T4 115 X STATISTICAL ANALYSIS: FRONT ENTRANCE No. of Tests T Estimator Mean Failure Load: Sample Standard Deviation: Minimum -Characteristic Resistance Force: Sincerely, Cleary Inspections Service, Inc. e 'ne I eary Miami -Dade Lab Certification No. 16.0211.02 n= 4 P = 3.182 F= 116.25 Ibf SF= 7.4 Ibf F'= 104.47lbf ' N 2�2t[1f3 R.N. Sailappan, P.E. Florida Registration No. 46696 - 9 Cleary Inspection Service, Inc. Telephone (561) 722-9881 Fax (561) 582-8039 Email: kc@kcwand.com Notes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance for (F') determined in compliance with Section 9 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Roof Area Building and Parapet Heights. (If no parapet exists. "N/A") N/A 15' Ground Level Page 4 1 41' 8' 38' Cleary Inspection Service, Inc. Tel. (561) 722-988, Fax (561) 582-8039 Email: clearyinspections@kcwand.com St. Lucie County Road and gHdge'Traffic Building 3071 0leanderAvenue Fort Pierce, FL Test Date; 2/15%2018 132' NOT DRAWN TO SCALE Drawings & measurements are approximate representation of Feld layout Page 5 38' 8' tom.:, L,•x:. CERTIFICATE OF CALIBRATION TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY AND PERFORMED IN ACCORDANCE WITH IS010012-2003 THIS DEVICE IS CERTIFIED TO BE WITHIN +1- 0.5% OF FULL SCALE READING AT EACH TEST POINT AT THE TIME OF SHIPMENT CERTIFICATE NUMBER: 24859 CALIBRATION DATE: 1/23/2018 PART AND CUSTOMER INFORMATION MODEL#: DFG2NI2000 SERIAL#: 20606019 CUSTOMER: CLEARY INSPECTION SERVICE INC. CUSTOMER#: CLE33460 CALIBRATION DATA APPLIED EXPECTED FULL VALUE VALUE I RUN AVERAGE SCALE (LB) (LB) j (LB) (LB) ERROR 0.00 -0.00 I 0.000 0.000 0.000% 100.00 400.00 400.00 I 402.00D 402.000 0.100% 600.00 800.00 800.00 804.000 804.000 0.200% 1000.00 1200.00 1200.00 1 1197.000 1197.000 -0.150% 1400.00 j 1600.00 1600.00 1599.000 1599.000 -0.050% 1800.00 j 2000.00 2000.00 j 2004.000 2004.000 0.200% CALIBRATION EQUIPMENT USED SERIAL #1: 11706016 SERIAL #2: CAL EQUIP: COMTEN INDUSTRIES load cell CNR EA, S/N I CNR EA 11706016 was calibrated at ComTen Industries following to ASTM E-74. The uncertainty is 2 CAL DATE: Lbf. Report No: 20300 6112/2017 I j THIS EQUIPMENT IS CERTIFIED TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. I CONDITIONS TEMPERATURE 70`F RELATIVE HUMIDITY: 31 % AS FOUND NOTES: (' Indicates that the part was out of tolerance) VALIDATION v ` Y CALIBRATION f CERTIFIED PERFORMED BY: CC U�TR r �Y Calibration not valid without CERTIFIED stamp and initials 6405-49th Street North, Pinellas Park, FL 33781-5724 * 727-520-1200 * FAX 727-520-0299 E-Mail: sales@com-ten.com * Web: www.com-ten.com