Loading...
HomeMy WebLinkAboutFORENSIC ENGINEERING CONSULTANTS FORMForensic engineering Consaftants, Inc. BASE SHEET ATTACHMENT CALCULATIONS Project Name St. Lucie County Road & Bridge Division Report No.: TRS-BS-18.011 Project Address 3071 Oleadder Avenue Fort Pierce, FL - 34982 Deck Substrate Wood Mean Roof Height 12.0 Feet Configuration Low Slope Roof Area (Approx.) SCANNED 6186 Sq.Ft. Category III Max. Roof Width 49.0 Feet Exposure Condition C BY Perimeter Width St. 4.8 Feet Building Type Enclosed Lucie County Parapet Height 0.0 Feet Base Wind Speed 180 mph Corner Zones 4.8' x 4.8' Each Slope V Uplift Pressures qz 0.0 Slope H 12.0 q: K: KA 60.227 0.850 1.005 0.00256 Kz Kr Kd V2 Ka V 0.85 180 Slope Angle' 0.00 P = q= (GCP - GCPi) GCP GCP; -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Corner Field PI alt -71.07 psf P1 asd -42.64 psf Perimeter P2 n.-119.25 psf P2 asd -71.55 psf Corner P3 A -179.48 psf P3 asd-107.69 psf Proposed System Johns Manville SBS Modified Bitumen Roof Systems Product Approval No. FL2948-R12 (Page 8 of 50) System No. W-16 System Design Pressure -52.5 psf Fasteners UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates Base Sheet Width 39 inches Side Lap 4 inches Net Width 35 inches Fastener Spacing in Lap of Base Sheet 8 inches # Rows 1 Fastener Spacing in Field of Base Sheet 8 inches # Rows 3 Min, Characteristic Resistance Force -25.52 Ibf Fastener Spacing {(MCRF/P;) x 144)/Row Spacing No. of Rows of Fasteners 4 5 6 7 Field Fastener Spacing 9.85 12.31 14.77 17.24 Perimeter Fastener Spacing 5.87 7.34 8.81 10.27 Comer Fastener Spacing 3.90 4.88 5.85 6.83 RECOMMENDED BASE SHEET ATTACHMENT PATTERN Field 1 row in the laps at 8 inches o.c. 3 rows in the center of sheet at 8 inches o.c. Perimeter 1 row in the laps at 7 inches o.c. 4 rows in the center of sheet at 7 inches o.c. Corner 1 row in the laps at 5 inches o.c. 5 rows in the center of sheet at 5 inches o.c. These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Follow all life safety & fire safety requirements of the Florida Building Code and OSHA requirements. Sincerely Fojc Engineering Consultants, Inc. OR R. ncpN. ailEngi n, P.E. FILE CAO' principal Engineer - Florida Registration No. 46696 Forensic Engineering Consultants, Inc. (CA #8265), P.O.Box 970034, Boca Raton, FL - 33497 Ph (561) 901 8490 Fax (561) 218 3830 Forensic engineering Consultants, Inc. BASE SHEET ATTACHMENT CALCULATIONS Project Name St. Lucie County Road & Bridge Division Report No.: TRS-BS-17.016 Project Address 3071 Oleadder Avenue (Revised) Fort Pierce, FL - 34982 Deck Substrate Wood Mean Roof Height 12.0 Feet Configuration Low Slope Roof Area (Approx.) 6186Sq. Ft. Category III Max. Roof Width 49.0 Feet Exposure Condition C Perimeter Width 4.8 Feet Building Type Enclosed Parapet Height 0.0 Feet Base Wind Speed 180 mph Corner Zones 4.8' x 4.8' Each Slope V 0.0 Slope H 12.0 Slope Angle° 0.00 Uplift Pressures qz = 0.00256 Kz Kn Kd V2 P = q� (GCP - GCP;) qz K. Kit Kd V GCP GCP; 60.227 0.850 1.005 0.85 180 -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Corner Field Pt Uft. -71.07 psf Pt asd -42.64 psf Perimeter P2 n. -119.25 psf P2asd -71.55 psf Corner P3 an. -179.48 psf P3 asd-107.69 psf Proposed System Johns Manville SBS Modified Bitumen Roof Systems Product Approval No. FL2948-R12 (Page 9 of 50) System No. W-20 System Design Pressure -60 psf Fasteners 11 ga. Annular Ring Shank Nails and 32 ga. 1-5/8" dia. Tin Caps Base Sheet Width 39 inches Side Lap 4 inches Net Width 35 inches Fastener Spacing in Lap of Base Sheet 9 inches # Rows 1 Fastener Spacing in Field of Base Sheet 9 inches # Rows 2 Min. Characteristic Resistance Force -43.75 Ibf Fastener Spacing {(MCRF/Pi) x 144}/Row Spacing No. of Rows of Fasteners 3 4 6 Field Fastener Spacing 12.66 16.89 21.11 25.33 Perimeter Fastener Spacing 7.55 10.06 12.58 15.09 Corner Fastener Spacing 5.01 6.69 8.36 10.03 RECOMMENDED BASE SHEET ATTACHMENT PATTERN Field 1 row in the laps at 9 inches o.c. 2 rows in the center of sheet at 9 inches o.c. Perimeter 1 row in the laps at 9 inches o.c. 3 rows in the center of sheet at 9 inches o.c. Corner 1 row in the laps at 6 inches o.c. 3 rows in the center of sheet at 6 inches o.c. These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Follow all life safety & fire safety requirements of the Florida Building Code and OSHA requirements. Sincerely Fore is Engi eenng Consultants, Inc. flip ' 8 ;g R. eSailappan, P.E. 2� I Principal Engineer fill Florida Registration No. 46696 ' Forensic Engineering Consultants, Inc. (CA #8265), P.O.Box 970034, Boca Raton, FL - 33497 Ph (561) 901 8490 Fax (561) 218 3830