Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866)184-8550 www.flaridaengineeringandteng.com SCANNED 25o S.W.13th Avenue N Pompano Beach, FL 33069 BY DATE: 3/01118 St. Lucie County JOB ORDER #: 18-911 CLIENT: Onshore Roofing ADDRESS: 4401 S.E. Commerce Avenue Stuart. Florida 34997 PROJECT: Island Dunes Country Clubhouse — Entegra Bella High "S" ADDRESS: 8735 S Ocean Drive Jensen Beach, Florida 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Roof Height = 25' Exposure: D Basic/Ultimate Wind Speed: V it 170 mph Length= 36'to 101' Category: 11 Nominal Wind Speed: V.d=Vint*40.6 Width = 23' to 85' Slope: 3/12 to 6/12 (asd = allowable strength design) Parapet Wall: N/A Clubhouse & = 1.12, Kzt =1.0, Kd = 0.85 Note: The most conservative dimensions were utilized for the design calculations below. Design Calculations: Velocity Pressure: q = 0.00256*K KzXdV2 Velocity Pressure (,do: q=0.00256(1.12)(1.0)(0.85)(170)2] = 70.43 psf Velocity Pressure (.d): q=0.00256(1.12)(1.0)(0.85)(170*40.6)2] = 42.26 psf Width of Pressure Coefficient: 0.1(85') = 8.5' 0.4(25') = 10.0' } use: 8'6" Effective Wind Area: <10ft2 For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -0.9 2) GCP2 = -1.7 3) GCP3 = -2.6 Internal Pressure Coefficient: 1) GCPi = 0.18 rig Qualify Ae-�/.3sa��rance Cn'' " Page 2, Job Order # 18-9 .` Onshore Roofing Island Dunes Country Clubhouse Sloped Tile (Bella High "S") Roof 8735 S Ocean Drive; Jensen Beach, Florida: Design Pressures Based on Vasd: 1) Field Pl = 42.26*[(-0.9) — (0.18)] = -45.6 psf 2) Perimeter P2 = 42.26* [(-1.7) — (0.18)] = -79.4 psf 3) Corners P3 = 42.26* [(-2.6) — (0.18)] = -117.5 psf Attachment Requirements Per RAS 127 (Entegra Bella High "S" Tilel: Tile System: Moment Based Aerodynamic Multiplier: 0.378 f0 (Direct Deck Application - Table 1) Restoring moment due to gravity: Mg = 6.51 ft. lb (Table 2) Attachment resistance expressed as a moment: Mf= 94 ft-lb Polyset AH-160 Adhesive Set (Table 4, Independent Large Paddy 63g) 1) Field : Mrl = ( 45.6*0.378) — 6.51 ft. lb =10.7 ft. lb. < 94 ft. lb = PASS 2) Perimeter: Mr2 = ( 79.4*0.378) — 6.51 ft. lb = 23.5 ft. lb. < 94 ft. lb = PASS 3) Comers : Mr3 = (117.5*0.378) — 6.51 ft. lb = 37.9 ft. lb. < 94 ft. lb = PASS System is acceptable as approved with single independent large paddy (63g) placement of Polyset AH-160 (by ICP Adhesives and Sealants) based on the requirements of Florida Product Approval FL7804-R10. Notes: Corners and perimeter area dimension shall not be less than a = 8'6" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify X\�jVVUbn?j///// with specifications. _g�CAly �j Sincerely, \�� LiceN BF Sim' No n 2 'O= /�P = o * — n Szg�_ Mark A. Mesiano, '•,,c oR : Q- Florida Engineering . thk • ��`�� Florida Reg. No. 4820�1/j ENG�� Certificate of AuthorizatioX4QI