Loading...
HomeMy WebLinkAboutINSPECTION CARDSCANNED Inspection Card BY Planning & Development Services Permit # : 1801-0678 St LUCIP. CDUnt Building &Code Regulation Division Online address: y 230DVifginia Avenue. http:/Niww.s0udeco.orQuick planning/permitting.htm k Links: Fort Pierce, FL 34982 Permit Status Lookup Phone:(772)462.2172 Fax:(772)462-6443 Online Building Inspection System Page 1 of Permit# SLC-1801-0678 #Confirmation 239 Status ISS Issued: 2/21/2018 Type: BUILDING COMMERCIAL Job Location: 4551 St Lucie Blvd City: Fort Pierce Jurisdiction: SAINT LUCIE COUNTY Parcel: 1431-120-0000-000/6 Subdivision: Lot: Block: Flood: X Elev: Flood Map: 176F Set backs: Left: Right: Front: Rear: i � Job Description: Phase 1: 106,250 S.F. Pre -Engineered Metal Bldg. W/25,500 S.F. Covered Multi -Purpose Canopy[ Foundation And Slab -On -Grade Is On Permit Number 1711-0360 ] . Site Is Approx. 36 Acres With Existing 9.6 Acre Lake. (2) New Concrete Entry Driveways, New Asphalt Parking Lot" Occupancy Classification Is F-1 • Construction Type Is 1 B' . I Building Is Fully Sprinklered • Occupant Load For Both Phases Is 2350 People' Square Footage This Phase Is f 131,750 • Maverick Boat Group' Internal Dunk Tank Has Been Eliminated From This Permit' The Interior Steel Floor System And Up -Stair Section Is Not Part Of This Permit r Contractor Ronald H Foulks — Cert # 10237 R F Concrete Construction Inc (772) 567-3356 664 Old Dixie Hwy Vero Beach, FL 32962 n Permit No Status 1801-0678-01 Issued 1801-0678.02 Issued 1801-0678-03 Issued SUB -PERMITS Permit Tyne Cert # ELECTRIC - COMMERCIAL 17660 MECHANICAL/HVAC COMMERCIAL 4426 - INCLUDES HOODS DBA Complete Electric Inc Three G's, Inc PLUMBING -COMMERCIAL 21073 Snyder Plumbing Of The Treasure Coast Inc Owner/Builder For the automated inspection system call (866) 284-1280. To schedule an inspection online go to http://codeinspectionpublic.stiucieco.gov. All inspections requested prior to 9:00 PM will be scheduled for the next business day. Inspection requests between 9:00 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance please contact the Building Department at (772) 462-2172. Inspection Notes: permit# Code Description Priority Schad. Date Res Description Inspector 1801-0678 901 ZONING COMPLIANCE 0 1801-0678 118 COLUMN 1 3/V2018 91 Partial Approval Andy Wentz 1sl lift marked on plans Report prepared on 5/11/2018 11:02:49 AM Insp. Date 31V2018 Planning & Development Services Building & Code Regulation Division 2300 Virginla Avenue. Fort Pierce; FL 34982 Phone:V72)462.2172 Fax:V72)462.6443 Inspection Card Permit # : 1801-0678 Online address: hffp:/Avww.stluciece.org/planning/permilting.htm Quick Links: Permit Status Lookup Online Building Inspection System Cancelled by 1801-0678 118 COLUMN 1 3/13/2018 75 Contractor/Cust Greg Smyth 3/13/2018 omer 1801-0678 118 COLUMN 1 3/22/2018 91 Partial Approval Clyde Heffelfinger 3/22/2018 First lift continued. Marked on plan. Two dowels missing at expansion joint in blocKwork. Contractor to epoxy dowels in place. Not per plan. FBC107.4 1801-0678 118 COLUMN 1 3/29/2018 91 Partial Approval Andy Wentz 3/29/2018 marked on plans 1801-0678 118 COLUMN 1 4/3/2018 91 Partial Approval Andy Wentz 4/3/2018 Marked on plans 1801-0678 118 COLUMN 1 4/6/2018 90 Approved Andy Wentz 4/612018 i 1801-0678 128 BOND BEAM 1 311312018 91 Partial Approval Greg Smyth 311312018 j1801-0678 128 BOND BEAM 1 4/3/2018 91 Partial Approval Andy Wentz 4/3/2018 !! Marked on plans 1801-0678 128 BOND BEAM 1 4/6/2018 90 Approved Andy Wentz 4/6/2018 1801-0678 140 CONSTRUCTION 1 4/24/2018 71 Rollover to Next Clyde Heffelfinger 4/24/2018 ROUGH FRAMING Day t METAL BUILDING WILL BE INSPECTED BY MIKE LUE. Contractor was not ready for AM inspection. 1801-0678 140 CONSTRUCTION 1 4/25/2018 91 Partial Approval Clyde Heffelfinger 4/2512018 ROUGH FRAMING 2 x 6 metal framing on top of blockwall approved. Location marked on plan. Detail needed fortop of wall/f'ire barrier and 5/8" drywall where it meets vinyl backed insulation at roof deck. 1801-0678 140 CONSTRUCTION 1 • - ROUGH FRAMING 1801-0678 141 INSULATION 1 5/7/2018 91 Partial Approval Andy Wentz 5/7/2018 CORE FILL 500 FOAM INSULATION USED IN C.B. SECTIONS CONTRACTOR SENDING IN CERTIFICATION FOR THIS JMC 1801-0678 141 INSULATION 1 5/8/2018 91 Partial Approval Andy Wentz 5/8/2018 FIREWALL BATT INSULATION 1801-0678 141 INSULATION 1 1801-0678 141 INSULATION 1 I1801-0678 148 WINDOW/DOOR ATTACHMENT 1 5/712018 91 Partial Approval Andy Wentz 5/7/2018 i marked on plans 1801-0678 148 WINDOW/DOOR 1 ATTACHMENT j1801-0678 179 FIREWALL 1 5/7/2018 91 DRYWALL SCREW INSPECTION ONE SIDE OF WALL marked on plans south side 1801-0678 179 FIREWALL 1 5/11/2018 0 FACTORY SIDE '1801-0678 187 REVISION PICKED UP 1 3/21/2018 90 03/19/2018 REVISION FOR PLUMBING PARTITIONS 1801-0678 187 REVISION PICKED UP 1 6/4/2018 90 05/0112018 REVISION PICKED UP BY BARRY MCGEE. :1801-0678 425 SEWER CONNECT 1 4/10/2018 91 PARTIAL FROM GRID LINE 18 DOWN TO 1 OUTSIDE OF BUILDING UNDERGROUND Partial Approval Andy Wentz 5/7/2018 Pending Andy Wentz Approved Office 3/21/2018 Approved Office 514/2018 Partial Approval Andy Wentz 4/1012018 Report prepared on 5/11/2018 11:02:50 AM Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 Inspection Card Permit#:1801-0678 Online address: hhp:/Av .stiucieco.org/planning/perrnitting.htm Quick Links: Permit Status Lockup Online Building Inspection System 1801-0678 425 SEWER CONNECT 1 1801-0678 705 FIRE DEPARTMENT 1 5/7/2018 0 Pending Fd FIREWALL DRYWALL SCREW INSPECTION ONE SIDE OF WALL 1801-0678 900 PLAN REVISION 1 3/19/2018 92 Accepted as Joe Cicio 3/19/2018 noted PLAN REVISION: MODIFY THE C.B. WALLS BEHIND THE PLUMBING FIXTURES TO 2" X 8" METAL FRAME WALLS PER PLANS' JMC 1801-0678 908 DEFERRED SUBMITTAL 1 5/1/2018 92 Accepted as Joe Cicio 5/l/2018 - OFFICE noted SUBMITTING REVISED AFFIDAVITS AND PRODUCT APPROVAL FOR THE STOREFRONT AND WINDOWSRECEIVED 0 8 _,sJ 4 R0. E-�Gf��� 4 )1801-0678 416 RAINWATER ROUGH 2 1 ENGINEERS REPORT- 11801-0678 106 ORIGINAL -TURN INTO 3 -ARK NU UTA_gjGROUNbSiFQL 1801-0678 238 ELECTRIC ROUGH 3 1801-0678 351 MECHANICAL ROUGH- 3 IN(DUCTS) 1801-0678 424 TOP OUT LESS TUB 3 1801-0678 908 DEFERRED SUBMITTAL 3 -OFFICE �TX *S�k' �'hIDTkFn :+K'x+n7 YC�var�gaa� i'A�E�A�A�E,P�ERMIYFOR7HE GOMMERCIAL�RF21G�!`TIO t SM1�t x5'j'E� W$(GN-pR�OF�E.SSJONA P,J,4NStIN�DAIP,y�IC 1801-0678 141 INSULATION 4 1801-0678 438 BOLLARDS 4 ;1801-0678 456 FIRESPRINKLER 4 ROUGH DEFERRED SUBMITTAL ;1601-0678 908 4 _OFFICE NilTf�,;i El �AA�,] 712Au'ED, (� O S OMiT1'!• f .14L G1, IG.1 rok SILR};IJ�R�EQ[?+RF-Y EWj�,SEFaED �j. j1801-0678 147 DRYWALL 5 POWER RELEASE 1801-0678 259 FORM (30 DAY FOR 5 TESTING) OFFICE 1801-0678 260 30 DAY FOR TESTING 5 1801-0678 165 HANDICAP RESTROOMS 6 1801-0678 180 BUILDING FINAL 6 1801-0678 280 ELECTRIC FINAL 6 1801-0678 380 MECHANICAL FINAL 6 1801-0678 457 FIRE SPRINKLER FINAL 6 1801-0678 480 PLUMBING FINAL 6 1801-0678 494 BOCC/PLANNING 6 RESOLUTIONS Report prepared on 5/11/2018 11:02:50 AM M Planning '& Development Services Building&.Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)4626443 CONDITIONS OF APPROVAL RESOLUTION 2017-112 1801-0678 700 FIRE DEPARTMENT 6 FINAL 1801-0678 740 WATER QUALITY 6 1801-0678 750 ENGINEERING 6 PAVING AND DRAINAGE 1801-0678 801 6 CERTIFICATION 1801-0678 803 PARKING/HANDICAP 6 SIGN & STRIPES 1801-0678 805 ENVIRONMENTAL 6 1801-0678 808 LANDSCAPING/FREES 6 1801-0678 gp3 TEST & BALANCE 6 REPORT i 1801-0678 908 DEFERRED SUBMITTAL 6 FINAL TERMITE 1801-0678 996 TREATMENT -TURN 6 INTO OFFICE 1801-0678 999 FINAL INSPECTION 7 Total Inspections: 62 Inspection Card Permit # : 1801-0678 Online address: http:/Av .sbudeco.org/planning/permitting.htm Quick Links: Permit Status Lookup Online Building Inspection System Report prepared on 5/11/2018 11:02:50 AM