HomeMy WebLinkAboutPROJECT INFORMATIONm BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS CLADDM (f SF„) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FED ar BASIC WIND SPEED = 170 mph RISK CATEGORY l/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHO' ESALE) SCANNED St. Lucie Counr I LI c� , ol� aZ L-7c PEAK ROOF L•• LE55 THAN 7'-9' L- GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3" L•• GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATVE POSIRVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.B.D. ULTIMATE A.S.D. UL77MATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.7 86.4 51.8 > 15'-20' 80.4 48.2 107.E 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 2O'-25' 83.6 50.2 111.9 671 79.8 479 104.4 62.6 74.8 44.9 94.4 55.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 1077 64.6 773 46.4 g74 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 �. 48.7 102,¢ 67.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 127.5 72.9 87.2 52.3 109.9 65.9 ST. REVIEVVE-D Fov CON'- LANCE 3 R-EV101'1 U� �, .ly� DATE -7„ 11 :.HST BE I�PT ON PLAINS .a � ORNO JNS;"` i luN NYILLBE lLADE. WADMWS PEAK ROOF HEIGHT vs DESIGN WIND PRESSOR£ FOR COMPONENTS & CLADDING (P.S.F.) FOR ASCE 7- f 0 - PEAK ROOF HEIGHT GR ATER THAN 60 FEEr BASIC WIND SPEED = 170 mph RISK CATEGORY 11 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 12-3" L•' GREATER OR EQUAL THAN 72'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE I A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91. 1 > 80' - 90' 95.6 175.2 88.0 52.8 155.0 93.0 > - 7a0' 973 �58.4 178. IOTA 89.7 53.8 1579 94.7 > 100' - 120' 100.5 .3 184.2 .5 92.5 55.5 163.0 9t7 > 120' - 140' 103.2 51.9 189.2 113.5 95.1 57.1 167.4 1 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160' - 180' 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63. 1 185.1 111. 1 > 250' - 300' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133.1 711.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500'1 128.8 1 77.3 236.1 1 141.7 118.6 71.2 1 208.9 125.3 N - 1.) THIS CER77FIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY TMS ENGINEER, BASED ON ASCE 7-10, FOR A B4SIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE 77ME BUILDING PERMIT 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO ^Oh1PLY W ITH ALL APPLICABLE CODES. * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. It* L = STORM PANEL LENGTH, ACCORDION SHUTTER BL40E LENGTH OR 64HAMA SHUTTER HEIGHT. K** PRODUCTS WHICH BEAR A MAMI-DADE COUNTY OR A STATE OF FLORIDA APPROVAL y� ' JCEIN No.44167 PE , HE���� 2074 (5th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIESI ASCE 7-10 / WIND PRESSURE CHART AS SHOWN STORM PANELS, ACCORDION & BAHAMA SHUTTERS SCALE RISK CAT. l/ BLDGS 06171115 11 L E C O w c. WIND PRESSURE CHART GATE T TESTING ENCENEEA/NG COMPANY BASIC WIND SPEED = 170 mph W. J6 Sl Ste. J05, WWNt4 A44 . D. M166 EXPOSURE D. Kd = 0.85 15- %Q hone : (J0.5Js EB-00 . Fm : (Ja5)Hll-I5J7 may, nc 45YA'PlIOn MR' Rfs: Na CLSWFIMn a¢ DRAWING No 3 N. 006719 WLA. RELIT Jr. P.E. r an 11-m /" a - - FLORIDAR/Lia IF 44167 s J + mwvms _ SHEET 1 OF 7