HomeMy WebLinkAboutFIELD WITHDRAWL RESISTANCE TEST RESULTSSCANNED TESTING APPLICATION STANDARD (TAS) No.105-11 BY St. Lucie County APPENDIX TAS 105-A FIELD WITHDRAWAL RESISTANCE TEST RESULTS GENERAL INFORMATION: Job Name: City of Fort Pierce - Facilities Administration Building Job Address: 3071 Oleander Avenue Job Site Contact: Ft. Pierce, FL 34982 Therma Seal Roof Systems, LLC (561) 223-2096 TESTING AGENCY/EQUIPMENT INFORMATION: Note: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with TAS 105 Appendix T105-A Testing Agency: Address: Telephone: Fax: Email: Representative Name: Title: Cleary Inspection Services, Inc. 1017 North "H" Street Lake Worth, FL 33460 (561) 722 - 9881 (561) 582 - 8039 clearyinspections@kcwand.com Katherine I. Cleary Inspector Test Apparatus: COMTEN MODEL # DFG2W2000, SERIAL # 21710015 BUILDING/ROOF SYSTEM INFORMATION: Approx. Roof Area Height: Height: = 15 ft. Roof Area Dimensions: Length: = 101 ft. Second largest dim.: = 75 ft. Total roof area: = 6141 ft 2 Perimeter width: = 6 ft. Perimeter area: = 1572 ft.2 Corner area: = 528 R.2 Parapet Height: = N/A ft. FASTENER INSTALLATION INFORMATION: Is the fastener a self driller? Yes Tool: Rigid 18v 0-1800 rpm's Fastener type: # 14 Fastener Manufacturer: OMG TEST INFORMATION: Test Date: 1/17/2018 Number of Test Conducted 20 *Note the Location of all tests on 'Building Information', attached. FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Deck:* See TAS 105-11 to determine number of tests Steel i. i City of Fort Pierce - Facilities Administration Building 3071 Oleander Avenue Ft. Pierce, FL 34982 Cleary Inspection Service, Inc. Tel. (561) 722-9881, Fax (561) 582-8039 Email: clearyinspections@kcwand.com SAMPLE NO. PLAN IDENTIFIER INITIAL FAILURE LOAD FIELD PERIMETER CORNER 1 Tl 350 X 2 T2 295 X 3 T3 285 X 4 T4 350 X 5 T5 275 X 6 T6 250 X 7 T7 350 X 8 T8 315 X 9 T9 300 X 10 T10 290 X 11 T11 325 X 12 T12 285 X 13 T13 275 X 14 T14 295 X 15 T15 345 X 16 T16 305 X 17 T17 340 X 18 T18 295 X 19 T19 330 X 20 T20 325 X Recommend steel deck be examined at test location #6 where a low reading of 250 lbs was measured. STATISTICAL ANALYSIS: No. of Tests T Estimator Mean Failure Load: Sample Standard Deviation: Minimum -Characteristic Resistance Force: Sincerely, Cleary Inspections Service, Inc. at e- eI. Miami -Dade Certification No. 16.0211.02 n = 20 t' = 2.093 F= 309lbf SF= 28.61bf F'= 295.61bf eky- I8 R.N. Sailappan, Florida Registration No. 46696 V 2 Cleary Inspection Service, Inc. Telephone (561) 722-9881 Fax (561) 582-8039 Email: kc@kcwand.com Notes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance for (F') determined in compliance with Section 9 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. ffti�,r °atfeFro..rt ,,,h; tlties Atlmlnise1t/ar1aP(7,t�lelo2rnc0U �eBdr d. , m. g 070Aveuem3er� ort P;FL T®e1sx Roof Area Building and Parapet Heights. (If no parapet exists, "N/A") NIA 15, Ground Level Page 3 N 31' 32' T1 T2 T3 31' T5 Canopy T6 ' 11' T8 Recommend that steel deck be examine at test location Ty ; #T6, where a low resistance of 250 Ibs was measured. 70' T11 T12 T13 T14 T15 T16 T17 T18 20' 32' T10 Cleary Inspection Service, Inc. Tel. (561) 722-988, Fax (561) 582-8039 Email: clearyinspections@kcwand.com 12' T7 12' 11' T19 Cnoy16' 11' NOT DRAWN TO SCALE Drawings & measurements are approximate representation of field layout Page 4 CERTIFICATE OF CALIBRATION TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY AND PERFORMED IN ACCORDANCE WITH IS010012-2003 THIS DEVICE IS CERTIFIED TO BE WITHIN +/- 0.5% OF FULL SCALE READING AT EACH TEST POINT AT THE TIME OF SHIPMENT CERTIFICATE NUMBER: 24634 CALIBRATION DATE: 10/1812017 PART AND CUSTOMER INFORMATION MODEL* DFG2W2000 SERIAL#: 21710015 CUSTOMER: CLEARY INSPECTION SERVICE, INC. CUSTOMER #: CLE33460 i CALIBRATION APPLIED VALUE (LB) DATA EXPECTED I VALUE (LB) 11 RUN1 I I (LB) AVERAGE (LB) FULL SCALE ERROR 0.00 0.00 - i 0.000 0.000 0.000% 100.00 400.00 400.00 393.000 393.000 -0.350% 600.00 800.00 800.00 { 795.000 795.000 -0.250% 1000.00 1200.00 1200.00 1199.000 1199.000 -0.050% 1400.00 16D0.00 1600.00 f 1602.000 1602.000 0.100% 1800.00 2000.00 2000.00 I 2004.000 2004.000 0.200% CALIBRATION EQUIPMENT USED SERIAL #1: 11706016 CAL EQUIP: COMTEN INDUSTRIES load cell CNR EA, SIN CNR EA 11706016 was calibrated at ComTen Industries following to ASTM E-74. The uncertainty is 2 CAL DATE: Lbf. Report No: 20300 611212017 SERIAL #2: THIS EQUIPMENT IS CERTIFIED TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. CONDITIONS TEMPERATURE 76*F RELATIVE HUMIDITY: 30% AS FOUND NOTES: ( * Indicates that the partwas out of tolerance) VALIDATION CALIBRATION PERFORMED BY: CC Calibration not valid without CERTIFIED stamp and initials 6405-49th Street North, Pinellas Park, FL 33781-5724 * 727-520-1200 * FAX 727-520-0299 E-Mail: sales@com-ten.com * Web: www.com-ten.com