Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED BY FORM R405-2017 St. Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Name: KLASS ADDITION Buil r Name: rrm,ojedt 151 NE NARANJA AVENU MAR 212018Pe itOffice: ST.LUCIECOUNTY tate, Zip: FT. PIERCE, FL, Pe it Number: Owner: NATALIE & JEFFREY K SST. Lucie County, Permltthi 5' fiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce ty:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types(352.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=11.0 352.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (105.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 105.00 ft2 6. Conditioned Floor area above grade (ft2) 105 b. NIA R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(0.0 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: ADDITION 6 21 a. U-Factor: NIA ft2 SHGC: b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.2 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.000 14. Hot water systems - Replacement equipment ' Floor Types (105.0 sqft.) Insulation Area a. Electric Cap: 40 gallons i a. Raised Floor R=0.0 105.00 ft2 b. Conservation features EF: 0.920 b. NIA R= ft2 None c. N/A R= ft2 15. Credits CF, Patel Glass/Floor Area: 0.000 Total Proposed Modified Loads: 7.04 PASS Total Baseline Loads: 7.87 I hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this O�-t%E Code. calculation indicates compliance gi` i, "' - ,• o +� with the Florida Energy Code. rn„2•,; f? ;.'.•, °„ �O PREPA Before construction is completed v C DATE: -� this building will be inspected for O - y compliance with Section 553.908 * o I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. Q0 WF' �O OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). a- File Copy 3/1212018 2:42 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: Building Type: Own�e,...rrt Name: # of —Ass Builder Name: Permit Office: L Jurisdiction: Family Type: New/Existing: Comment: KLASS ADDITION Bedrooms: 0 User Conditioned Area: 105 NATALIE 8. JEFFREY KLAAS Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: ST. LUCIE COUNTY Whole House Fan: Single-family Addition Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 151 NE NARANJA AV St. Lucie FT. PIERCE, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 105 840 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ADDITION 105 840 No 1 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor ADDITION __ __ 105 ft' 0 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 114 ft' 0 ft' Medium 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 105 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 105 ft' 0.11 Wood 3/12/2018 2:42 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N _^:14 E _ 3 S 4 W Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood ADDITION 11 15 8 120.0 ft' 0.23 0.6 ADDITION 11 7 8 56.0 ft' 0.23 0.6 ADDITION 11 15 8 120.0 ft' 0.23 0.6 ADDITION 11 7 8 56.0 ft' 0.23 0.6 0 0 0 0 DOORS V. # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 N Insulated ADDITION None .46 3 6 8 20 ft' INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 98 5.38 10.12 .2598 7 HEATING SYSTEM If System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Existing/co None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Existing/confinne None SEER: 16 23.2 kBtu/hr 696 cfrn 0.75 1 sys#1 HOT WATER SYSTEM ,f # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # -- Supply — Location R-Value Area — Return -- Air CFM 25 CFM26 HVAC # Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 21 ft' Attic 5 ft2 Default Leakage ADDITION (Default) (Default) 1 1 3/12/2018 2:42 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 TEMPERATURES Programabl[Coolingre Thermosta[[tX:]�Y C[reiling Fans: HeDec Jan ([[rX��]] Mar r Apr ay IM May n[X] Jun ]Jul [ ] Aug [ ] Sep [ j L J Oct r[X�] Nov[[X]] Nov ng [ [ ]Feb lFeb xl [ Jun E ] Jul EX] ) Aug EX] 1 Sep lXl [X] [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/12/2018 2:42 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA ' Project Name: KLASS ADDITION Builder Name: Street: 151 NE NARANJA AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: NATALIE & JEFFREY KLAAS Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dro ed ceiling/soffit Y dropped 9 /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind noninn and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover plates and walls or ceilings U. ul auwuml, elbpeutlun ul log walls 5nall us in acwraance wan me provisions or IUG-4uu. 3/12/2018 2:43 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 89 The lower the EnergyPerformance Index, the more efficient the home. 151 NE NARANJA AVENUE, FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" Description a. U-Factor: N/A SHGC: b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: Addition Single-family 1 0(0) No 105 Area ft' ft' ft' ft. 0.000 ft. 0.000 8. Floor Types Insulation Area a. Raised Floor R=0.0 105.00 ft' b. N/A R= fF c. N/A R= ft' 9. Wall Types a. Frame - Wood, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: ADDITION 12. Cooling systems a. Central Unit Insulation R=11.0 R= R= R= Insulation R=30.0 R= R= Area 352.00 ft' ft' ft' ft' Area 105.00 ft' fF ft' R ft' 6 21 kBtu/hr Efficiency 23.2 SEER:16.00 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 17.0 COP:1.00 14. Hot water systems - Replacement equipment a. Electric Cap: 40 gallons EF: 0.92 b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: CF. Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/12/2018 2:43 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Pro ect SummaryJob: wri8 htsoft. Entre House Byte: Mar 12, 2018 QUICK CALCS, INC. .317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fa;c 772466-6796 Email: OUICKCALCS@AOL.COM Proiect Information For: KLAASADDITION 151 NE NARANJAAVENUE, FT. PIERCE,FL Notes: Design• • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 75 15 L 50 61 OF OF OF % gr/lb Heating Summary Structure 12242 Btuh Ducts 3449 Btuh Central vent (17 cfm) 535 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 16226 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Cooling Area (ft' 965 965 Volume �ft') 8685 8685 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 65 33 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 17448 Btuh 21 OF 773 cfm 0.049 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 10610 Btuh Ducts 5247 Btuh Central vent (17 cfm) 286 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 15335 Btuh Latent Cooling Equipment Load Sizing Structure 1391 Btuh Ducts 1413 Btuh Central vent (17 cfm) 726 Btuh Outside air Equipment latent load 3529 Btuh Equipment total load 18864 Btuh Req. total capacity at 0.70 SHR 1.8 ton Cooling Equipment Summary Make Carrier Trade EXISTING SYSTEM Cond CA14NA0240000A Coil FV4CNF003L AHRI ref Efficiency 12.0 EER, 16 SEER Sensible cooling 16240 Btuh Latent cooling 6960 Btuh Total cooling 23200 Btuh Actual air flow �rp� Air flow factor RO.'94AUdPf� Btuh Static pressure -- -D.50 RRII RR20 Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightSoft' Right-Sufte® Universal201717.0.14 RSU08101 2018-Mar-12 14:16:01 Page 1 Projectl.mp CaIc=MJB Front Door faces: N I# wrightsoft• Right-l®Worksheet Job: Entire House Date: Mar12,2018 QUICK CALCS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire Horse 143.0 ft 9.0 ft d 965.0 ft- EXr BEDS 99.0 ft 9.0 ft heat/cool 20.0 x 43.0 ft 860.0 ft. Ty Carstmctiol number U-value (Btul✓RL*F) Or HTM (BtuWft-) Am (ftj or perimeter (ft) Load (Btuh) Am (ft� a perimeter (ft) Load (Btuh) Heat Cad Gross NIP/S Heat Cod Gross N/P/S Heat Cod 8 11 ---_.---._--�-__-C____,___ W__ lAr W- - W .W_ VN T-G W- l(V 128-0sw___�. IA-clo s IA-Osw _ ____ _ _128-05w_ 13A-4ocs 128-0sw_ 13A-4ocs 1Aclom _ 12B_Osw_e_ 13A-0acs 1Actorn 1Aclom 16B0ad 22A-tpl _ __0.143 1.270 - _ -.1.270 _ 0.097 0.143 _0.097 0.143 _ 1.270 _0.097 0.143 1.270 1.270 _0 032 0.989 _n_ n _n_ _e_ e_ _s_ s _5 _w_ w w w _ - __272 5.56 _ 35.56 _272 _4.00 __272 4.00 35.56 ___272 4.00 35.56 35.56 _0.90 27.69 _-255 255 _ 34.77 ,_2.58 _ 2.55 _2.58 255 34.77 _=258 255 91.12 91.12 _7.68 0.00 _^180 1is __15 _._63 144 _`135 180 15 ,63 387 6 30 =860 860 -___.._____-r.___13A-40_____-_.___�._ 165 160 __ _ _ -Q __-- 63 ___144 _ _._135 165 30 __W 351 0 0 _ �866 99 _661 561 _ _533 �17.1. .__.,�420 522 __ 522 �163 367 _r348 420 522 __163'---0 80 115 _ _ 15 0 0 561 1 533_ ._,_. 0 _ 677 -0 _ 522 522 , _0 367 160 _ _-_ _0 ___ 0 __ _144 ,__0 165 _ _15 __0 577 _-367. 661 533 - 71 1405 213 _1067 771. 144 �0 _ �0. 420 522 _i0 180 15 661 _ 533 -- 0 893 547 _2734 �1445 _ _ -0 387 6 30 _ 755 86099 351 0 _ 0 _755 1405 213 1067 _676 2742 893 547 _ 2734 _ 1268 _ 0 t�--(('` . _ _ C, F 2742 6 c) AED exausim 1171 1171 Envelopeloss/gain 10238 10061 9068 8863 12 a) Infiltration b) Roan ventilation 2004 0 649 0 1388 0 380 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 12242 10610 10456 9243 14 15 Less external load Less transfer Redslributiol Subtotal Duct loads 28% 49910 I 0 0 0 12242 3449 0 0 0 10610 5247 28% 49% 0 0 0 10456 2946 0 0 0 9243 4571 Total room load Air required (cfm) 15692 773 15856 773 13402 660 13813 673 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsof , Right -Suite® Universal 2017 17.0.14 RSU08101 2018-Mar-12 14:16:01 04CC*'� Projectl.rup Calc=MJB Front Doorfaces: N Page wrightsoft, Right-JO Worksheet Job: Entire House Date: Mar 12, 2018 QUICK CALCS, INC. By. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dmensions Room area NEW DRESSING 44.0 R 9.0 It heal/cool 15.0 x 7.0 ft 105.0 ft- Ty Construction number U-value (Btul yft�'F) Or HTM (Btuh/ft-) Area (W) a perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/PIS Heat Cool Gross NIP/S Heat Cool 6 . 11 Vy� 15✓ .T`„G ,W__ W W V}1 . _—.- I—G _128-05w 13A4ocs 1AC1orn_�,�__ -126.11sw_.�_, 13A-4ocs 12B_=05w_ 13A-4ocs 1AciOm .128 0sw 13A-4ocs 1AcIon 1AC1an 166-30ad. 22A-tpl ,_,_0.097 0.143 1.270 `0.097 ^0.143 _0.097 0.143 _1.270 _0 097 _n._ n n _e_ a _w_ s s -w_ �2.72 4.00 35.56 272 4.00 �272 4.00 35.56 _2 72 4.00 3556 3556 =0 90 27.69 =258 2.55 34.77 258 2.55 _,258 255 34.77 =258 255 91.12 91.12 _1.68 .= 133 0 _0 =63 0 _.135. 0 0 �63 0 0 0 = 105 135 0 0 =63. 0 �35 0 0 . =63 0 0 0 _367, 0 0 ____348 0 0 =63 _ ,_17.1 0 _,_;367. 0 0. 0 � 348 0 0 ^-- --- ' 0.143 1270 1270 =0 032 _ 0.989 w w w _-_ �17..1 0 0 0 _94 ____'163 0 0 0 _176 0 F =105 -- — _ _ 6 c) AED excursion 0 Envelope lass/gain 1170 1198 12 a) Infiltration b) Room ventilation 617 0 169 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 1786 1367 14 15 Less external Iced Less transfer Redistribution Subtotal Duct loads 28% 49% 0 0 0 1788 503 0 0 0 1367 676 Total mom load Air raauired (orm) 2290 113 2043 100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoft' Right-Sufle® Universal 2017 17.0.14 RSU08101 2018-Mar-12 14:16:01 .CA Projectl.rup Calc=MJ8 Front Doorfaces: N Page