Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
INPUT DATA REPORT
SCANNED Ciro F ® m h BY o EnergyGauge Summits v6.00 St. Lucie County °' m o M INPUT DATA REPORT Proiect Information Project Name: 2075-JokerWild-2-TI Orientation: 0 Deg Clockwise alls &Windows will be rotated accordingly Project Title: Jokers Wild-2-TI Building Type: Retail Address: 8297 S US#1 Building Classification: Renovation to existing building State: Florida No.ofStories: j Zip: 34958 GrossArea: 1360 SF Owner: Sharkey Air Zones No Acronym Description Type Area Multiplier TotalArea fsll lsfl 1 PrOZo4-Adjac Zone 4- Adjacent CONDITIONED 9.0 1 9.0 ❑ ent 2. Pr0Zo5-Adjac Zones -Adjacent CONDITIONED 9.0 1 9.0 ❑ ent 3 PrOZol-Recep Zone 1-Reception CONDITIONED 55.0 1 55.0 ❑ tion 4 PrOZo2 Zone 2 - Restroom CONDITIONED 44.0 1 44.0 ❑ -Restroom 1/22/2019 EnergyGauge Summit® v6.00 5 Pr0Zo6-Break Zone 6- Brealaroom CONDITIONED 121.0 1 121.0 ❑ room 6 Pr0Zo7-Vestib Zone 6-Office 1 CONDITIONED 104.5 1 104.5 ❑ ale 7 PrOZo7-Storer Zone 6-Storeroom CONDITIONED 77.0 1 77.0 ❑ Gore 8 PrOZo7-Game Zone 6-GameRoom l CONDITIONED 896.0 1 896.0 ❑ Room 1 9 PrOZo7-Restro Zone 6-Restrooml CONDITIONED 44.0 1 44.0 ❑ oml No Acronym Description Type In Zone: PrOZo4-Adjacent I Pr0Zo4Sp1 Zo0Sp1 MediumBulkyMaterial Storage In Zone: PrOZo5-Adjacent 1 Pr0Zo5Sp1 Zo0Sp1 Medium/Bulky Material Storage In Zone: PrOZol-Reception 1 PrOZOlSpl ZoOSpl- Reception Lobby (General) - Reception and Waiting In Zone: Pr0Zo2-Restroom 1 PrOZo3Sp2 ZoOSp2 Staff Restroom Toilet and Washroom In Zone: PrOZo6-Breakroom 1 PrOZo6Spl Zo6Sp1-Offrcel03 Food Service - Bar/Lounge In Zone: PrOZo7-Vestibule 1 PrOZo7Spl Zo7Spl-Offrcel04 Office - Enclosed In Zone: PrOZo7-Storeroom 1 PrOZo7Sp1 Zo7Spl- Storeroom Storage & Warehouse - Inactive Storage In Zone: PrOZ0-Game Room I 1 PrOZ07Spl Zo7Spl-Treatment 117 Playing Area In Zone: Pr0Zo7-Restrooml 1 Pr0Zo7Sp1-RestZo7Sp1-Restroom1 Toilet and Washroom Spaces Depth Width Height Multi Total Area Total Volume IR] Ift] Ift] plier I111 Ict] 90.00 0.10 18.00 1 9.0 162.0 ❑ 90.00 0.10 18.00 1 9.0 162.0 ❑ 5.00 11.00 9.00 1 55.0 495.0 ❑ 5.50 8.00 9.00 1 44.0 396.0 ❑ 11.00 11.00 9.00 1 121.0 1089.0 ❑ 11.00 9.50 9.00 1 104.5 940.5 ❑ 11.00 7.00 9.00 1 77.0 693.0 ❑ 28.00 32.00 9.00 1 896.0 8064.0 ❑ 5.50 8.00 9.00 1 44.0 396.0 ❑ 1/22/2019 EnergyGauge Summit® v6.00 2 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W[ Ctrl pts In Zone: PrOZo4-Adjacent In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 5 5 Manual On/Off I In Zone: PrOZo5-Adjacent In Space: Pr0Zo5Sp1 I Compact Fluorescent General Lighting 1 5 5 Manual On/Off I El In Zone: PrOZol-Reception In Space: Pr0ZolSp1 1 LED General Lighting 1 32 32 Manual On/Off I In Zone: Pr0Zo2-Restroom In Space: PrOZo3Sp2 1 LED General Lighting 1 24 24 Manual On/Off 1 ❑ In Zone: PrOZo6-Breakroom In Space: Pr9Zo6Sp1 1 LED General Lighting 2 32 64 Manual On/Off 1 In Zone: PrOZo7-Vestibule In Space: Pr0Zo7Sp1 1 LED General Lighting 2 32 64 Manual On/Off I El In Zone: Pr0Zo7-Storeroom In Space: Pr0Zo7Sp1 1 LED General Lighting 1 10 10 Manual On/Off 1 In Zone: PrOZo7-Game Room I In Space: Pr0Zo7Sp1 1 LED General Lighting 4 32 128 Manual On/Off 2 ❑ In Zone: PrOZo7-Restrooml In Space: PrOZo7Spl-Restrooml 1 LED General Lighting 2 12 24 Manual On/Off 1 1/22/2019 EnergyGauge Summit® v6.00 3 Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effee) Multi Area Orientation Conductance Heat Dens. R-Value [ft] [fti plier [sf] [Bta/hr. sE F] Capacity [lb/c1] ]h.sEFBtu] [Btu/sEF] In Zone: PrOZol-Reception 1 PrOZol Wal-South 0.75 in. stucco, 5.00 9.00 1 45.0 South 0.0838 11.224 50.24 11.9 ❑ 2"styro8"CMU,lx2 x24"oe,airspace,0.5" gyp In Zone: PrOZo6-Breakroom 1 PrOZOlWe2-W 5/8"stucco 11.00 9.00 1 99.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24'bd.5" Gyp In Zone: PrOZ07-Vestibule 1 PrOZolWa2-South 124R19b 5.00 9.00 1 45.0 West 0.0339 0.864 5.47 29.5 ❑ In Zone: PrOZo7-Game Room I 1 PrOZolWa2-North 5/811stucco 32.00 9.00 1 288.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oct.5" GYP 2 Pr0Zo 1 Wa2-South 5/8" stucco 10.00 9.00 1 90.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"IS0 BTWN24"oe/.5" Gyp 3 PrOZol Wag -Partition 0.5 Ply/35/8" Mtl 35.00 9.00 1 315.0 Fast 0.0444 1.009 8.59 22.5 ❑ std a24"oc1R19/0.5" Gyp In Zone: PrOZ0-Restrooml I PrOZOlWa2-South 5/8"stucco 8.00 9.00 I 72.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 1/22/2019 EnergyGauge Summit@ v6.00 4 Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W R(Effec) Multi Total Area [Btothr sfF] IN [ftl plier [gf[ In Zone: PrOZo7-Game Room 1 In Wall: Pr0Zo6Wa1-N-Eat 1 Pr0Zo24WaIWiI North Yes 0.6000 0.42 0.39 4.00 5.00 6 120.0 01 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [it] [ft] plier [st] [Btu/hr. sf F] [Iblen [Btu/sf F] [h.sfF/Btu] In Zone: PrOZo7-Vestibule In Wall: Pr0Zo6Wal-S-Est 1 PrOZ09WalDrl Wood door, 2 in. No 3.00 7.00 1 21.0 0.4192 37.00 2.41 2.39 ❑ Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [it] [ft] plier [st] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/cq ]h.sf.FBtu] In Zone: PrOZol-Reception 1 Pr0ZoIRf1 Shngl/12"WD 11.00 5.00 1 55.0 0.00 0.0320 1.50 8.22 31.2 ❑ DeCUWD Truss/9" Batt/Gyp Brd In Zone: Pr0Z02 -Restroom 1 Pr0Zo3Rfl Shngl/12"WD 8.00 5.50 1 44.0 0.00 0.0320 1.50 8.22 31.2 ❑ Deck/WD Truss/9" Batt/Gyp Brd In Zone: Pr0Zo6-Breakroom 1 PrOZo1Rf1 ShngU1/2"WD 11.00 11.00 1 121.0 0.00 0.0320 1.50 8.22 31.2 ❑ DeckfWD Truss/9" Batt/Gyp Brd In Zone: PrOZo7-Vestibule 1/222019 EnergyGauge Summit® v6.00 I PrOZo7Rfl Shngl/1/2"WD 11.00 9.50 1 104.5 0.00 0.0320 1.50 8.22 31.2 ❑ Deck/WD Truss/9" Batt/Gyp Brd In Zone: PrOZO-Storeroom 1 PrOZ07Rfl ShngV1/2"WD 7.00 8.00 1 56.0 0.00 0.0320 1.50 8.22 31.2 ❑ Deck/WD Truss/9" Batt/Gyp Brd In Zone: PrOZo7-Game Room 1 I PrOZo7Rfl Built-up Gravel/2" 32.00 28.00 1 896.0 0.00 0.1486 0.98 12.59 6.7 ❑ ISO/Mtl Deck In Zone: PrOZo7-Restrooml 1 PrOZo7Rfl 0.5 Ply/35/8" Mtl 8.00 5.50 1 44.0 0.00 0.0798 0.54 7.98 12.5 ❑ std@24"oc/Rl l/0.5" Gyp Skylights No Description Type U SHGC Vis.Trans W H(Effee) Multiplier Area Total Area [Btu/hr sfF] [ft] [ft] [Sf] ISf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [R] plier [sf] [Btu/hr. sE F] [Btu/sE F] [lb/cf[ [h.sf.FBtu] In Zone: PrOZo4-Adjacent 1 PrOZo3Fl1 Concrete floor, 0.10 90.00 1 9.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZoS-Adjacent 1 PrOZo3Fl1 Concrete floor, 0.10 90.00 1 9.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZol-Reception 1/22/2019 EnergyGauge Summit® v6.00 I Pr0ZolFl1 Concrete floor, I1.00 5.00 1 55.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo2-Restroom I Pr0Zo3Fll Concrete floor, 8.00 5.50 1 44.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo6-Breakroom 1 Pr0ZOIFII Concrete floor, 11.00 11.00 1 121.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo7-Vestibule 1 Pr0Zo7F11 Concrete floor, 11.00 9.50 1 104.5 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo7-Storeroom 1 PrOZ01711 Concrete floor, 7.00 8.00 1 56.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo7-Game Room I I Pr0Z07FII Concrete floor, 32.00 28.00 1 896.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: PrOZo7-Restrooml I PrOZo7Fl1 Concrete floor, 8.00 5.50 1 44.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad Systems PrOsyl System 1 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 3 4 Cooling System Air Handling System -Supply Air Distribution System (Sup) Air Distribution System (Ret) 58000.00 16.00 8.00 1800.00 0.60 8.00 8.00 ❑ ❑ ❑ ❑ 1/22/2019 EnergyGauge Summit® v6.00 7 PrOSy3 System 3 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 3 4 Cooling System Air Handling System -Supply Air Distribution System (Sup) Air Distribution System (Ret) 50.00 16.00 50.00 0.80 6.00 6.00 8.00 PrOSy4 System 1 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV I 2 3 4 Cooling System Air Handling System -Supply Air Distribution System (Sup) Air Distribution System (Ret) 50.00 16.00 50.00 0.60 8.00 8.00 8.00 Plant Equipment Category Size Inst.No Elf. IPLV Water Heaters W-Beater Description Capacity Cap.Unit I/P Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Leo/No. of units Control Type Wattage Luminaires Luminaire Isf/ft/Nal [WJ 01 U22/2019 EnergyGauge Summit® v6.00 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [Btu-in/h.sf F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sLF] ASHULDblTntW User Defined 2 0.6000 0.4200 0.3900 ❑ d-Vy-Fg frm Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sLFBtu] [ftl [Btu/h.ft.Fl [lb/cfl [Btu/lb.Fl 18 Matl18 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 Lj 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/21N 151 Mad151 CONCHW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 11 215 Mat1215 POLYSTYRENE, EXP., 21N, No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 105 Mat1105 CONC BLK HW, 81N, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 1/22/2019 EnergyGauge Summit® v6.00 9 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oe No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 211 Mat1211 POLYSTYRENE,EXP.,1/2IN No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 82 Mat182 ASPHALT-SHINGLEAND Yes 0.4400 ❑ SIDING 11 Mat111 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAGI/2IN 91 Matl91 BUILDING PAPER, Yes 0.0600 ❑ PERMEABLE FELT 407 Matl407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 414 Matl414 R-8 generic Insulation No 8.0000 0.1746 0.0218 0.30 0.2000 ❑ 80 Mat180 AIR LAYER, 4IN OR Yes 0.9200 ❑ MORE, HORIZ. ROOFS Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sf.FI [lb/ct] [hsf.FBtu] 1001 Wood door, 2 in. No No 0.42 2.41 37.00 2.4 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 18 2 in. Wood 0.1670 0.000 ❑ 1/22/2019 EnergyGauge Summit® v6.00 10 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [Ib/cf] [h.sEFBm] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 4IN 0.3333 0.000 ❑ 2 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sEF] [Ib/cf] [h.sf.FBm] 1010 0.75 in. stucco, No No 0.08 11.22 50.24 11.9 ❑ 2"styro,8"CMU,1x2x24"oc airspace,0.5"gyp Layer Material Material Thickness Framing No. [ft] Factor 1 267 0.75" stucco 0.0625 0.000 ❑ 2 187 GYP OR PLAS BOARD,121N 0.0417 0.000 ❑ 3 215 POLYSTYRENE, EXR, 2IN, 0.1667 0.000 ❑ 4 105 CONC BLK HW, SIN, HOLLOW 0.6667 0.000 ❑ 5 256 WOOD, SOFT, 1-1/21N 0.1250 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] ]Ib/cQ [h.sEFBtu] 1011 518" stucco 18"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oel.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 ❑ 1/222019 EnergyGauge Summit® v6.00 11 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [lb/cf] [h.sEFBtu] 1015 0.5 Ply/35/8" Mtl std ,24"oc/Rl 1/0.5" Gyp No No 0.09 0.54 7.98 12.5 ❑ Layer Material Material Thickness Framing No. [R] Factor 1 211 POLYSTYRENE,02J2IN, 0.0417 0.000 ❑ 2 12 3 in. Insulation 0.2500 0.000 ❑ 3 187 GYP OR PLAS BOARD,121N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [lb/cf] [h.sEFBtu] 1017 0.5 Ply/35/8" Mtl std@24"oe/RI9/0.5" Gyp No No 0.04 1.01 8.59 22.5 ❑ Layer Material Material Thickness Framing No. [it] Factor 1 211 POLYSTYRENE,EXP.,1/21N, 0.0417 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ 3 187 GYP OR PLAS BOARD,121N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [lb/cf] [h.sEFBtu] 1038 Shngl/l/2"WD Deck/WDTruss/9" Batt/Gyp No No 0.03 1.50 8.22 31.2 ❑ Brd Layer Material Material Thickness Framing No. 1111 Factor 1 81 ASPHALT -ROOFING, ROLL 0.000 ❑ 2 244 PLYWOOD, 121N 0.0417 0.000 ❑ 3 12 3 in. Insulation 0.2500 0.000 ❑ 4 23 6 in. Insulation 0.5000 0.000 ❑ 5 187 GYP OR PLAS BOARD,121N 0.0417 0.000 ❑ 1222019 EnetgyGauge Summit® v6.00 12 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cn [h.sf.FBtu] 1045 Built-up Gravel/2" ISO/Mtl Deck No No 0.15 0.98 12.59 6.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 248 ROOF GRAVEL OR SLAGI/2IN 0.0417 0.000 ❑ 2 11 2 in. Insulation 0.1670 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/b.sf.F] [Btu/sEF] [Ib/cl] [h.sEFBtu] 1053 T241119b No No 0.03 0.86 5.47 29.5 ❑ Layer Material Material Thickness Framing No. [B] Factor 1 82 ASPHALT -SHINGLE AND SIDING 0.000 ❑ 2 91 BUILDING PAPER, PERMEABLE FELT 0.000 ❑ 3 244 PLYWOOD, 1/2IN 0.0417 0.000 ❑ 4 414 R-8 generic Insulatrion 0.1746 0.000 ❑ 5 407 R-19 Generic Insulation 0.4147 0.000 ❑ 6 80 AIR LAYER, 4IN OR MORE, HORIZ. 0.000 ❑ ROOFS 7 187 GYPORPLASBOARD,1/2IN 0.0417 0.000 ❑ 1/22/2019 EnergyGauge Summit& v6.00 13