Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONJokers Wild Tenant Imp. HVAC Load Analysis for 'CAN N ' Sharkey Air SW Jack James Drive Stuart, FL 34997 SCANNED By St. Lucie Countv CHVACHVAC Logos Prepared By: John Ahem John M. Ahern, Architect 2674 S.E. Willoughby Boulevard Stuart, FL 34994 772-220-9907 Tuesday, January 22, 2019 Chvac- Full Commercial HVAGLoads Calculation Program kCc,t1VE:� lite Software Development, Inc. Ahern &'Associates, Architects -- Jokers Wild Tenant Imp. Stuart.FL'34994 Paqe,2 Building Summary Loads Building peaks in August at 3pm. ST. Lucie CoMy, Permitling Bldg Load Area Se " °/aTot 1�at en Net %°Ninety Descai io uan Loss oss Gain . ain Gain aim Roof 1,353 2,698 11.86 0 3,090 3,090 5.33 Wall 613 2,568 11.29 0 815 815 1.41 Glass 121 2,851 12.53 0 3,629 3,629 6.26 Floor Slab 110 1,783 7.84 0 0 0 0.00 Skin Loads 9,901 43.52 0 7,534 7,534 13.00 Lighting 2,570 0 0.00 0 9,205 9,205 15.88 Equipment 2,114 0 0.00 0 7,327 7,327 12.64 Pool Latent 0 0 0.00 0 0 0 0.00 People 21 0 0.00 4,576 4,992 9,568 16.51 Partition 252 39 0.17 0 41 41 0.07 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 345 0 0.00 14,321 5,687 20,009 34.52 Heat. Vent. 345 12,285 54.00 0 0 0 0.00 Cool.lnfil. 0 0 0.00 0 0 0 0.00 Heat.lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 2,012 2,012 3.47 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 523 2.30 0 1,637 1,637 2.82 Return Dud 0 0 0.00 0 629 629 1.09 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 22,747 100.00 18,897 39,064 57,961 100.00 Buliding Sen %Tot Lat Sen Net %Net; Su:Mal, Loss Lo Gain Gain Gain Gain.. Ventilation 12,285 54.00 14,321 5,687 20,009 34.52 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Room Loads 9,940 43.70 4,576 29,098 33,674 58.10 Plenum Loads 0 0.00 0 0 0 0.00 Fan/DucUMisc Loads 523 2.30 0 4,278 4,278 7.38 Building Totals 22,747 100.00 18,897 39,064 57,961 100.00 CCheck�Fi �u`res Total Building Supply Air (based on a 200 TD): 1,490 CFM Total Building Vent. Air (23.16% of Supply): 345 CFM Total Conditioned Air Space: 1,353 Sq.ft Supply Air Per Unit Area: 1.1015 CFM/Sq.ft Area Per Cooling Capacity: 280.0 Sq.ti/Ton Cooling Capacity Per Area: 0.0036 Tons/Sq.ft Heating Capacity Per Area: 16.82 Btuh/Sq.ft Total Heating Required With Outside Air: 22,747 Btuh Total Cooling Required With Outside Air: 4.83 Tons 11SERVERAWNsys ...t2075 SharkeyAir-JokersWild-2-TI.CH8 Tuesday, January 22, 2019, 07:47 AM 1 Reception 55 394 1,264 440 7.5/P 7.5/P 5pm August 2 19 62 0 15 15 Zn 1 495 0.35 1.13 0 14 14 Runout duct size: 5 in. dia, Diffusers: 1, CFM/runout: 62, Velocity: 454.1 ft/min, Pressure drop: 0.171 in.wg./100ft 2 Breakroom 121 762 2,454 660 7.5/P 7.5/P 5pm August 3 37 120 0 23 23 Zn 1 1,089 0.31 0.99 0 26 28 Runout duct size: 6 in. dia, Diffusers: 1, CFM/runout: 120, Velocity: 611.9 ft/min, Pressure drop: 0.239 in.wg./100ft 3 Vestibule 105 658 1,778 660 7.5/P 7.5/P 5pm August 3 32 87 0 23 23 Zn 1 941 0.31 0.83 0 23 20 Runout duct size: 5 in. dia, Diffusers: 1, CFM/runout: 87, Velocity: 638.6 ft/min, Pressure drop: 0.335 in.wg./100ft 4 Store Room 88 122 722 0 5/P 5/P 3pm August 0 6 35 0 0 0 Zn 1 792 0.07 0.40 0 4 8 Runout duct size: 4 in. dia, Diffusers: 1, CFMlrunout: 35, Velocity: 405.4 ft/min, Pressure drop: 0.187 in.wg./100ft 5 Restroom#1 44 493 471 0 Direct Direct 5pm August 0 24 23 75 75 75 Zn 1 352 0.55 0.52 75 17 5 Runout duct size: 4 in. dia, Diffusers: 1, CFM/runout: 23, Velocity: 264.1 ft/min, Pressure drop: 0.081 in.wg./100ft 6 Restroom#2 44 61 398 0 Direct Direct 3pm August 0 3 19 0 75 75 Zn 1 352 0.07 0.44 0 2 5 Runout duct size: 4 in. dia, Diffusers: 1, CFM/runout: 19, Velocity: 223.3 ft/min, Pressure drop: 0.058 in.wg./100ft 7 Gaming Room #1 896 7,450 23,336 3,960 7.5/P 7.5/P 3pm August 18 363 1,143 0 135 135 Zn 1 8,064 0.41 1.28 0 259 265 Runout duct size: 8 in. dia, Diffusers: 6, CFM/runout: 190, Velocity: 545.E ft/min, Pressure drop: 0.128 in.wg./100ft Room Peak Totals: 1,353 9,940 30,423 5,720 Total Rooms: 7 26 485 1,490 75 345 345 Unique Rooms: 7 12,085 0.36 1.10 75 345 345 Main trunk duct size: 16 in. h x 161n. w, Velocity: 838.0 ft/min, Pressure drop: 0.086 in.wg./100ft \1SERVERAtntwsys...12075_SharkeyAir-JokersWild-2-TI.CH8 Tuesday, January 22, 2019, 07:47 AM Air Handler Description: AHU #1 Constant Volume -Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.79 HP Fan Input: 65% motor and fan efficiency with 2.2 in. water across the fan Sensible Heat Ratio: 0.88 --- This system occurs 1 time(s) in the building. -- Air System Peak Time: 3pm in August Outdoor Conditions: Clg: 90' DB, 78' WB, 125.80 grains, Htg: 420 DB Indoor Conditions: Clg: 75' DB, 50% RH, Htg: 750 DB Summer: Ventilation controls outside air, -- Winter: Ventilation controls outside air. Room Space sensible loss: 9,940 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 12,285 Btuh 345 CFM Supply Duct sensible loss: 523 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 22,747 Btuh Heating Supply Air: 10,463 / (.999 X 1.08 X 20) = 485 CFM Winter Vent Outside Air (71.2% of supply) = 345 CFM Room space sensible gain: 29,098 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 2,012 Btuh Supply duct sensible gain: 1,637 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 32,747 Btuh Cooling Supply Air. 32,747 / (.999 X 1.1 X 20) = 1,490 CFM Summer Vent Outside Air (232% of supply) = 345 CFM Return duct sensible gain: 629 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 5,687 Btuh 345 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 6,316 Btuh Total sensible gain on air handling system: 39,064 Btuh Room space latent gain: 4,576 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 14,321 Btuh Total latent gain on air handling system: 18,897 Btuh Total system sensible and latent gain: 57,961 Btuh Total Air Handler Supply Air (based on a 200 TD): 1,490 CFM Total Air Handler Vent. Air (23.16% of Supply): 345 CFM Total Conditioned Air Space: 1,353 Sq.ft Supply Air Per Unit Area: 1.1015 CFM/Sq.ft Area Per Cooling Capacity: 280.0 Sq.ft/Ton Cooling Capacity Per Area: 0.0036 Tons/Sq.ft Heating Capacity Per Area: 16.82 Btuh/Sq.ft Total Heating Required With Outside Air: 22,747 Btuh Total Cooling Required With Outside Air: 4.83 Tons 6SERVERAIntwsys ...\2075 SharkeyAirJokersWild-2-TI.CHB Tuesday, January 22, 2019, 07:47 AM -,Full Commercial HVAC Loads Calculation Program - Elite Software Development, Inc . 1Chyac Ahern & Associates, Architects Jokers Wild Tenant Imp. ,9tuart, FL 3499A- - Pa 5 Zone Detailed Loads At Zone Peak Times Load Jinit U.Fac/ Conv. Radiant Total Lat. Htg. Htg. Descri`tion Qdan 'Usa a S.Gain S.Gain S.Gain Gain Mult. Los Roo ,1=Rea do --Air°Handl r-AH 1 -Zone 1 peaks (sensible)in August t 3prn. Roof-1-UP-Type:10 55 0.065 32 91 123 2.145 118 Wall-1-S-Type:26 45 0.121 22 36 58 3.993 180 Lights-Prof=1 125 1.000 345 63 408 Equipment-Prof=1 36 1.000 92 24 116 0 People-Prof=1 2.0 1.000 200 233 433 400 Floor slab 5 15.510 78 Sub -total 1,138 400 375 Safety factors: +10% +10% +5% Total w/ safety factors: 1,252 440 �394 Room 2-Breakroom - Air Handler 1 AHU #1 Zone 1 peaks sensible in August at 3 m. Roof-1-UP-Type:2 121 0.040 42 125 167 1.320 160 Wall-1-S-Type:26 99 0.121 48 79 127 3.993 395 Lights-Prof=1 250 1.000 691 126 817 Equipment-Prof=1 138 1.000 375 73 448 0 People-Prof=1 3.0 1.000 300 350 650 600 Floor slab 11 15.510 171 Sub -total 2,209 600 726 Safety factors: +10% +10% +5% Total w/ safety factors: 2,430 660 762 Room -Vestibule- Air Handler 1 AHU #1 Zone 1 peaks sensible in August at 3 m. Roof-1-UP-Type:2 105 0.040 36 108 144 1.320 138 Wall-1-S-Type:26 65 0.121 31 51 83 3.993 258 Door-2-S-Type:26 21 0.121 10 17 27 3.993 84 Lights-Prof=1 175 1.000 239 279 517 Equipment-Prof=1 52 1.000 143 28 170 0 People-Prof=1 3.0 1.000 300 350 650 600 Floor slab 10 15.510 147 Sub -total 1,591 600 627 Safety factors: +10% +10% +5% Total w/ safety factors: 1,751 W660 ^658 Room 4-Store Room - Air Handler`l AHU #1 Zone 1 peaks sensible in Au ust at 3 m. Roof-1-UP-Type:2 88 0.040 30 144 175 1.320 116 Lights-Prof=1 100 1.000 239 96 334 Equipment-Prof=1 44 1.000 120 28 148 0 Sub -total 657 0 116 Safety factors: +10% +10% +5% Total w/ safety factors: �722 �0 122 11SERVERAVrtwsys ...T075 SharkeyAirJokersWild-2-TI.CH8 Tuesday, January 22, 2019, 07:47 AM CFgvac - Full Commercial HVAC'. Loads Calculation Program - -- Elite Software Development, Inca Ahern 8 Associates,_ Architects I Jokers Wild Tenant Imp. ua L 34 - a Zone Detailed Loads At Zone Peak Times cont'd Load Unit , U.Fac/< -Conv. Radiant ` Total Lat. Htg:: Htg. Descri tion uan Usa 'e S1Gain S.Gain S.Gain Gain Mult. - toss R 5-R s r om#1AirrHandl r 1' AHU #1 Zoe 1 peaks (sensible)in August t 3 m: Roof-1-UP-Type:2 44 0.040 15 46 61 1.320 58 Wall-1-S-Type:26 72 0.121 35 57 92 3.993 287 Lights-Prof=1 60 1.000 143 48 191 Equipment-Prof=1 22 1.000 60 12 72 0 Floor slab 8 15.510 124 Sub -total 416 0 470 Safety factors: +10% +10% +5% Total w/ safety factors: 457 ' 0 493 Room 6-Restroom#2 - Air Handler 1 AHU #1 Zone peaks sensible in August at3 m. Roof-1-UP-Type:2 44 0.040 15 72 87 1.320 58 Lights-Prof=1 60 1.000 143 57 200 Equipment-Prof=1 22 1.000 60 14 74 0 Sub -total 362 0 58 Safety factors: +10% +10% +5% Total w/ safety factors: 398 0 61 R " om 7-Gaminct Roornftl'-= Air Handler 1 AHU #1 Zone 1.peaks (sensible) °in August at-3pm. Roof-1-UP-Type:10 896 0.065 516 1,537 2,053 2.145 1,922 Wall-1-N-Type:26 221 0.121 83 146 229 3.993 882 Wall-3-S-Type:26 90 0.121 48 77 125 3.993 359 Partition-2-1 252 0.049 37 0 37 0.147 37 GIs-N-1-0%S 100.0 0.700 1,239 1,468 2,707 22.440 2,244 Unshaded Beam 100.0 0 20 20 GIs-N-1-0%S 21.0 0.700 260 308 568 22.440 471 Unshaded Beam 21.0 0 4 4 Lights-Prof=1 1,800 1.000 4,975 925 5,900 Equipment-Prof=1 1,800 1.000 3,685 1,947 5,632 0 People-Prof=1 18.0 1.000 1,800 2,140 3,940 3,600 Floor slab 76 15.510 1,179 Sub -total 21,215 3,600 7,095 Safety factors: +10% +10% +5% Total w/ safety factors: 23,336 3,960 7,450 \%SERVERA\ntwsys ...12075 SharkeyAiWokersWild-2-TI.CH8 Tuesday, January 22, 2019. 07:47 AM CIlvac Full Commercial HVAC Loads Calculation Program Ahern& Associates, Architects Elite Software Development, Inc. Jokers Wild renant.Imp. tua I_ _. _ _ _ a 71 Room Detailed Loads At Room Peak Times Load Unit U.Fac/ Conv. Radiant Total Lat. Htg. Htg. Descri tion uan Usage S.Gain S.Gain S.Gain Gain Mult. Loss Room 1-Reception peaks (sensible) in August at 5pm, Air Handier 1 (AHU #1), Zone 1, 11.0 x 5.0, Construction Type: 16 Exterior Heavy Construction, No Carpet, 10% Glass Roof-1-UP-Type:10 55 0.065 23 88 111 2.145 118 Wall-1-S-Type:26 45 0.121 29 40 69 3.993 180 Lights-Prof=1 125 1.000 345 65 411 Equipment-Prof=1 36 1.000 92 25 117 0 People-Prof=1 2.0 1.000 200 242 442 400 Floor slab 5 15.510 78 Sub -total 1,149 400 375 Safety factors: +10% +10% +5% Total w/ safety factors: 1,264 440 394 Equipment Cooli Loads Nominal Quantity Nominal Quantity Sensible Latent Item Output Type Output Type Load Load Name Sensible Sensible Latent Latent Btuh Btuh Laptop computer, Manufacturer 1 2.0 GHz processor, 2 GB 36 watts 0 Btuh 117 0 RAM, 17 in. screen Total 117 0 oom 2-Breakroom peaks (sensible) in August at 5pm, Air Handler 1 (AHU #1), Zone 1, 11.0 x 11.0, Construction Type: 16 Exterior Heavy Construction No Carpet, 10% Glass Roof-1-UP-Type:2 121 0.040 28 116 144 1.320 160 Wall-1-S-Type:26 99 0.121 65 87 152 3.993 395 Lights-Prof=1 250 1.000 691 130 821 Equipment-Prof=1 138 1.000 375 76 451 0 People-Prof=1 3.0 1.000 300 362 662 600 Floor slab 11 15.510 171 Sub -total 2,230 600 726 Safety factors: +10% +10% +5% Total w/ safety factors: 2,454 660 762 EouiDment Cooling Loads Nominal Quantity Nominal Quantity Sensible Latent Item Output Type Output Type Load Load Name Sensible Sensible Latent Latent Btuh Btuh Snack machine (B) _ 275 watts 0 watts 451 0 Total 451 0 IRoom 3-Vestibule peaks (sensible) in August at 5pm, Air Handler 1 (AHU #1), Zone 1, 9.5 x 11.0, Construction Type: 16 Exterior Heavy Construction No Ca et 10% Glass Roof-1-UP-Type:2 105 0.040 24 100 124 1.320 138 Wall-1-S-Type:26 65 0.121 42 57 99 3.993 258 Door-2-S-Type:26 21 0.121 14 19 32 3.993 84 \\SERVERA\ntwsys ...t2075_SharkeyAir lokersWild-2-TI.CH8 Tuesday, January 22, 2019, 07:47 AM hvac - Full Commercial HVAC Loads Calculation Program - - - - - Elite Software Development, Inc._ ern 8 Associates, Architects Jokers Wild Tenant Imp. tuart, FL — oom Detailed Loads At Room Peak Times cont'd Load Unit U.Fac/ Conv. Radiant Total Lat. Htg. Htg. Descri tion Quan Usacie S.Gain S.Gain S.Gain Gain Mult. Loss Lights-Prof=1 175 1.000 239 288 527 Equipment-Prof=1 52 1.000 143 29 171 0 People-Prof=1 3.0 1.000 300 362 662 600 Floor slab 10 15.510 147 Sub -total 1,616 600 627 Safety factors: +10% +10% `660 +5% Total w/ safety factors: 1,778 658 Room 4-Store Room peaks (sensible) in August at 3pm, Air Handler 1 (AHU #1), Zone 1, 11.0 x 8.0, Construction Type: 20 Interior. Light Construction No Car et Roof-1-UP-Type:2 88 0.040 30 144 175 1.320 116 Lights-Prof=1 100 1.000 239 95 334 Equipment-Prof=1 44 1.000 120 28 148 0 Sub -total 657 0 116 Safety factors: +10% +10% +5% _ Total w/ safety factors: 722 0 122 Room 5-Restroom#1 peaks (sensible) in August at 5pm, Air Handler 1 (AHU #1), Zone 1, 8.0 x 5.5, Construction Type: 15 Exterior. Heavy Construction, No Carpet, 1 % Glass Roof-1-UP-Type:2 44 0.040 10 42 52 1.320 58 Wall-1-S-Type:26 72 0.121 47 64 111 3.993 287 Lights-Prof=1 60 1.000 143 49 193 Equipment -Prof 1 22 1.000 60 12 72 0 Floor slab 8 15.510 124 Sub -total 428 0 470 Safety factors: +10% +10% +5% Total w/ safety factors: 471 0 493 Room 6-Restroom#2 peaks (sensible) in August at 3pm, Air Handler 1 (AHU #1), Zone 1, 8.0 x 5.5, Construction Type: 20 Interior Light ConstructionNo Carpet) Roof-1-UP-Type:2 44 0.040 15 72 87 1.320 58 Lights-Prof=1 60 1.000 143 57 200 Equipment-Prof=1 22 1.000 60 14 74 0 Sub -total 362 0 58 Safety factors: +10% +10% +5% Total w/ safety factors: 398 0 61 Room 7-Gaming Room #1 peaks (sensible) in August at 3pm, Air Handler 1 (AHU #1), Zone 1, 32.0 x 28.0, Construction Type: 17(Exterior. Heayy Construction, No Carpet, 50% Glass) Roof-1-UP-Type:10 896 0.065 516 1,537 2,053 2.145 1,922 Wall-1-N-Type:26 221 0.121 83 146 229 3.993 882 Wall-3-S-Type:26 90 0.121 48 77 125 3.993 359 1\SERVERAXntwsys...'2075_SharkeyAiWokersWild-2-TI.CHB Tuesday, January 22, 2019. 07:47 AM hvac - Full Commercial HVAC. Loads Calculation Program- jr$. - Elite Software Development, Inc. hero 8 Associates, Architects J'hy Jokers Wild Tenant Imp,. ua Pa oom Detailed Loads At Room Peak Times cont'd Load Unit U.Fac/ Conv. Radiant Total Lat. Htg. Htg. Descri tion Quan Usage S.Gain S.Gain S.Gain Gain Mult. Loss Partition-2-1 252 0.049 37 0 37 0.147 37 GIs-N-1-0%S 100.0 0.700 1,239 1,468 2,707 22.440 2,244 Unshaded Beam 100.0 0 20 20 GIs-N-1-0%S 21.0 0.700 260 308 568 22.440 471 Unshaded Beam 21.0 0 4 4 Lights-Prof=1 1,800 1.000 4,975 925 5,900 Equipment-Prof=1 1,800 1.000 3,685 1,947 5,632 0 People-Prof=1 18.0 1.000 1,800 2,140 3,940 3,600 Floor slab 76 15.510 1,179 Sub -total 21,215 3,600 7,095 Safety factors: +10% +10% +5% Total w/ safety factors: 23,336 3,960 7,450 Equipment CoolingLoads Item Nominal -Quantity Output Type' Nominal output Quantity, ' Type Sensible Load Latent Load ame Sensible Sensible Latent Latent Btuh Btuh Flat -panel monitor, Manufacturer X (model A) 30 in. screen 90 watts 0 Btuh 5,632 0 Total 5,632 0 - WERVERAWwsys... \2075_SharkeyAir-JokersWild-2-TI.CHB Tuesday, January 22, 2019, 07:47 AM