Loading...
HomeMy WebLinkAboutNettles Blvd. 1185.pdfi` 4 U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on Pages 1-9 OMB No: 1660-008 Expiration Date: November 30, 2018 Copy all Pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A —PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name (Note:Notvolid to useforanyotherperson orentiry). Policy Number: ROBIN & CARMELLA PIZZY #4058-87 A2. Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Company NAIC Number: Box No. 1185 NETTLES BLVD. City State ZIP Code JENSEN BEACH FL 34957 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PARCEL 1185, NETTLES ISLAND, INC, A CONDO -SECTION II (#4502-501-1372-000-6) A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL AS. Latitude/Longitude: Lat. 27"16'58.8252"N Long: 80'13'29.5392"W Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number:8 A8. For a building with a crawlspace of enclosure(s): a) Square footage of crawlspace or enclosure(s) 956 sq. ft. b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A8.b 1320 sq. in. d) Engineered flood openings? ® Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage 0 sq. ft. b) NumbzP'of.permanen Jflcod openings in the attached garage within 1.0 foot above adjacent grade 0 c Total net area of flood o p=_nags in A9.b 0 sq. in. . i_ d)Fnginee Cd flood. iigs?_ ❑ Yes ® No =SECTION B —FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Bl. N5IP Community Name &-Community Number B2. County Name B3. State ST. LUl.UNINC. AREA'S:,:' 120285 ST. LUCIE FL 64. Map%Panel.. ,.. 85: Suffix B6. Firm Index B7. FIRM Panel 68. Flood Zone(s) B9. Base Flood Elevation(s) Number F Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 12211CO311 1 02/16/12 02/16/12 AE 7.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: BSl. Indicate Elevation Datum Used for BFE in Item B9: ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: _ B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area.(OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 1 of 6 ELEVATION CERTIFICATE OMB No: 1660-008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 1185 NETTLES BLVD. City State Zip Code Company NAIC Number: JENSEN BEACH FL 34957 SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) CS. Building Elevations are Based on: ❑ Construction Drawings' ❑ Building Under Construction' ® Finished Construction A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al - A30, AE, AH, A (with BFE), VE VI - V30, V (with BFE), AR, AR/A, AR/AE, AR/Al - A30, AR/AH, AR/AO. Complete Items C2.a - h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: 872 2312 G TIDAL Vertical Datum:NAVD 1988 Indicate elevation datum used for the elevations in Items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: _ Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of Bottom Floor (including basement, crawlspace, or enclosure floor) 4.87 ® feet ❑ meters b) Top of Next Higher Floor 8.5 ® feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A._ ❑ feet ❑ meters d) Attached garage (top of slab) N/A ❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 12.75 ® feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 4.53 ® feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 4.87 ® feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including N A. ❑feet ❑ meters structural support SECTION D -SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ® Yes ❑ No ®C here if at hments. Certifier's Name: License Number: Stephen J. Brown, PSM L.S. 4049 F7 , lac Title: Professional Surveyor and Mapper Company Name: — Stephen J. n, PSM LS. 4 e of Florida Stephen J. Brown, Inc. Address: 619 ESTR J hoot the signature and Nthe on of raised seal of a Florida City: State: Zip Code: SydART FL 34994 Lic sed Surveyor&Mapper" ignature: Date: Telephone: Stephen J. Brow , PS 08/08/19 (772) 288-7176 Copy all Pages of is a ' Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (incl of equipment and location, per C2(e), if applicable. A8 b EA EQUALS 220 SQ.FT. C2 e IS E OM OF THE A/C UNIT FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 2 of 6 V ..IA ELEVATION CERTIFICATE OMB No: 1660-008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 1185 NETTLES BLVD. City ,+ - State Zip Code Company NAIC Number: JENSEN BEACH FL 34957 SECTION E— BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (Without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA and or LOMR-F request, complete Sections A, B, and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, ❑ feet ❑ meters ❑ above or ❑ below the HAG crawlspace, or enclosure) is -- b) Top of bottom floor (including basement, ❑ feet ❑ meters ❑ above or ❑ below the LAG crawlspace,or enclosure) is E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of instructions), the next higher floor (elevation C2.b in ❑feet ❑ meters ❑ above or ❑ below the HAG the diagrams) of the building is -- E3. Attached Garage (top of slab) ❑ feet ❑ meters ❑ above or ❑ below the HAG E4. Top of platform of machinery and/or equipment El feet El meters Elabove or ❑below the HAG servicing the building is E5. Zone AO only: If no flood depth number is available, is the top of the floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name: Address City State Zip Code Signature Date Telephone Comments ❑ Check here if attachments FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 3 of 6 C .... a ti ELEVATION CERTIFICATE OMB No: 1660-008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 1185 NETTLES BLVD. City State Zip Code Company NAIC Number: JENSEN BEACH FL 34957 SECTION G—COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 — G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below). G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community issued BFE) or Zone AO. G3. ❑ The following information (Items G4— G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This Permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) ❑ feet ❑ meters Datum of the building: G9. BFE or (Zone AO) depth of flooding at the building site: _ _ ❑ feet ❑ meters Datum G10. Community's design flood elevation: _ _ ❑ feet ❑ meters Datum The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 4 of 6 BUILDING PHOTOGRAPHS OMB No: 1660-008 ELEVATION CERTIFICATE See Instructions for Item A6 Expiration Date: November 30,2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 1185 NETTLES BLVD. City State Zip Code Company NAIC Number: JENSEN BEACH FL 34957 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front view" and "Rear view"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. 1 08103119 &I 08103119 Photo One Caption: FRONT VIEW Photo Three Caption: REAR/SIDE VIEW i 08103119 08103119 Photo Four Caption: SIDE/REAR VIEW Photo Two Caption: FRONT/SIDE VIEW FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 5 of 6 T BUILDING PHOTOGRAPHS OMB No: 1660-008 ELEVATION CERTIFICATE See Instructions for Item A6 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No. or P.O. Route and Box No. Policy Number: 1185 NETTLES BLVD. City State Zip Code Company NAIC Number: JENSEN BEACH FL 34957 If Submitting more photographs that will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front view" and "Rearview"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. ,p i 'E HIS No i4 O8103119 08103119 Photo One Caption: REAR VIEW Photo Three Caption: SIDE VIEW L� k OP y,f 'R, h 08103119 08103119 Photo Two Caption: REAR/SIDE VIEW Photo Four Caption: FRONT/SIDE VIEW FEMA Form 086-0-33 (7/15) Replaces all previous editions Page 6 of 6 DIVISION: 08 00 00—OPENINGS SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS'Q AUG 0 ?> _ucle Ceunb/, PcFmitting REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 ICC ICC ICC PMG "1014 Recipient of Prestigious Western States Seismic Polity Council (WSSPC) Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation far its use. There is no warranty by ICC Evaluation Service, LLC, express or implies( as to any finding or other matter in this report, or as to any product covered by the report. Copyright m 2018 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-3560 www.icc-es.org 1 (800) 423-0587 1 (562) 699-0543 DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vente/Foundation Flood Vents REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012 and 2009 Intemalional Building Code® (IBC) ■ 2018, 2015, 2012 and 2009 International Residential Code® (IRC) Properties evaluated: ■ Physical operation ■ Water flow ■ Weathering 2.0 USES Flood Flaps automatic flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: Flood Flaps® automatic flood vents are engineered mechanically operated flood vents (FVs) that automatically allow flood waters to enter and exit enclosed areas. The FVs are constructed of ABS plastic which serves as the FV's housing, and a front grill that contains an anodized metal screen imbedded in polypropylene plastic. On contact with rising flood water, the grill will disengage from its secured position, allowing flood water and debris to flow through in either direction. The FVs are available in two series as described in Section 3.3. The sealed series models contain two rubber flaps that close the FV to the passage of air when using with conditioned areas or sealed crawl spaces. In the same manner as the grill, the two rubber flaps are pushed open by water pressure, allowing water and debris to flow through the FV in either direction. See Figure 1 for an illustration of the Flood Flaps® automatic FV. Reissued September 2018 This report is subject to renewal September 2019. A Subsidiary of the International Code Council® 3.2 Engineered Opening: The Flood Flaps automatic FVs comply with the design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC) [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)] for a rate of rise and fall of 5 feet per hour (0.423 mmis). In order to comply with the engineered opening requirement of ASCE/SEI 24, Flood Flaps automatic FVs must be installed in accordance with Section 4D. 3.3 Flood Vent Series Models: Flood Flaps® automatic FVs are available in two series with multiple models and sizes as described in Table 1. The sealed series models, designated FFWF, include two rubber flaps for the prevention of air flow. The multi- purpose series, designated FFNF, omits the rubber flaps. 3.4 Natural Ventilation: Flood Flaps® automatic FV models FFNF12, FFNF08, FFNF05, and FFNF02 have metal screens with '/4 inch by 114 inch (6 mm b� 6 mm) openings and provide 37 square inches (0.02 m ) of net free opening to supply natural ventilation for under -floor ventilation. Flood Flaps automatic FV models FFWF12, FFWF08, and FFWF05 have not been evaluated for use as openings for under- floor ventilation. 4.0 DESIGN AND INSTALLATION Flood Flaps® automatic FVs are designed to be installed into walls of existing or new construction. Installation of the FVs must be in accordance with the manufacturer's instructions, the applicable code and this report. Flood Flaps automatic FVs can be installed in wood, masonry and concrete walls up to a thickness of 12 inches (305 mm). In order to comply with the engineered opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 (2018 and 2015 IBC and IRC) [Section 2.6.2.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must be installed as follows: ■ Wth a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 220 square feet (20 m2) of enclosed area. ■ Below the base flood elevation. ■ With the bottom of the FV located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The Flood Flaps automatic flood vents described in this report comply with, or are suitable alternatives to what is I('(' -ES fvaluauon Reports are nor to he constued as representing aesthetics or any other attributes oat specifically addressei4 ner are they to be construed as an endorsement of the suhrect of the report or a recnrxmadarran frrr Ire use. There is no warranty by 1('(Evaluation 4rvicr, LL(', espress or implied. as m any finding or other maser in this report or as to any product covered by the report . Copyright 0 2018 ]CC Evaluation Service, LLC. All rights mm"d. Page 7 of 4 ESR-3560 I Most Widely Accepted and Trusted Page 2 of 4 specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 6.1 The Flood Flaps® automatic FVs must be installed in accordance with this report, the applicable code and the manufacturers installation instructions. In the event of a conflict, the instructions in this report govern. 5.2 The Flood Flaps automatic FVs must not be used in place of 'breakaway walls' in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised October 2017). 7.0 IDENTIFICATION 7.1 The Flood Flaps® models recognized in this report are identified by a label bearing the manufacturer's name, the model number, and the evaluation report number (ESR-3560). 7.2 The report holder's contact information is the following. FLOOD FLAPS®, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 29451 (843)881-0190 www.floodtiaps.com i n fo(a)floodf la os. c om TABLE 1—FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES MODEL NUMBER MODEL DESIGNATION ROUGH OPENING ( �dth X Height) (inches) VENT SIZE (W X H X D) (Inehes) ENCLOSED AREA COVERAGE (fe) NET FREE AREA OPENING' (in2) FF—WF12 Sealed Sens 16 x 8 15 1e X 1 XX 12 220 NA FFNF12 Multi -Purpose 16 x 8 15 /a X 734 X 12 220 37 FFWF08 Sealed Sens 16 x 8 15 /e x /. x 8 220 NA FFNFOS Mufli-PuMme 16 x 8 15 /s x rl, x 8 220 37 FFWF05 Sealed Series 16 x 8 15 /a x 731, x 5 220 NA FFNF05 Multi -Purpose 16 x 8 15 /s x /-, x 5 220 37 For Si: i inch = 25.4 mm; 1 fi = 0,M M- 'For under -floor venblab n only. FIGURE 1—FLOOD FLAPS' AUTOMATIC FLOOD VENT ESR-3560 I Most Widely Accepted and Trusted Page 3 of 4 FFWF12 12" DEPTH FFNF08 FIGURE 2—FLOOD FLAPS® AUTOMATIC FLOOD VENT SERIES MODELS 8" DEPTH FFNF05 FIGURE 3—FLOOD FLAPS® AUTOMATIC FLOOD VENTS MULTIPLE DEPTH OFFERINGS 5"DEPTH IMES Evaluation Report ESR-3560 FBC Supplement Reissued September 2018 This report is subject to renewal September 2019. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: FLOOD FLAPS®, LLC EVALUATION SUBJECT: FLOOD FLAPS®AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Flood Flaps automatic flood vents, recognized in ICC-ES master evaluation report ESR-3560, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS The Flood Flaps flood vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-3560, comply with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the 2015 Intemationai Building Code provisions noted in the master report. Use of the Flood Flaps flood vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued September 2018. /C('-ES Fvahmtom N Wrss are no, ra be mruvaed as representing aesthetics or any Whet atrnMres not spec jc.11y add essed nor ore thev ro be camrrued as an endorsement of the nob t,r o/the report or a econ,ev dmmn/ar us use. There - no ..1y by ICC h.'va/aa@an Service, LLC, upress or miloh d, as in ay finding or other matter in this report or as ro ay prahc, c,ovrmd by the report Copyright 0 2018 ICC Evaluation service, LLC. All rights reserved. Page 4 of 4