HomeMy WebLinkAboutBUILDING PLANSIL_J
-Nit
FYUNP O061
NK !II � FourvwnON
\11\� � ti^ TB�'1J� \' t EU6PNGATh,
EXISTING SITE PLAN
A+ SCALE: V-40'-0'
uj ® o
Z U
Qm U
U 3
EASTNO
OVERXFAD
FosTAN
GUSHER
CE
CT
D BAR
PROPOSEDATM
ENCLOSURGNICSK SEE
GCNERALNOTE,
STEELPIPEI
F
5
EO TINGD'UT UNDERGROUND
vHTNFO ALARM AR MDE
PXONE.ALPAM ANO VIDEO.
CONDUITS
Q
EXISTING PLAN
A+ SCALE: 1/3"-1'4"
DOIIAAD
eRIGHT SIDE ELEVATION
A+ SCALE:1l2"=1'-0"
(I
I
MSPNGIUOSK
FOUNDATION
EpSPNGAIN /
ExI6PNOUNDERGR0UND
PATH FCRPOYr£N.wTA.
PHONE. MPNO NDEO
CONDUITS
3 PROPOSED PLAN
A+ SCALE:10'-1'-0"
EXISTING
Digitally signed by Chester
C Scott.,
e: 18.03.01..° p. °.°L'
OS'00"m
L
53
9�
C53
PROPOSED.
MCLOSUREMlOSK Sa
sEEGENERPLNOTE,
GENERAL NOTES
L NSTPl1 HEWCOMPANION SYSTEMS ATM ENCLOSURE GROUNDELSPNGATM
MILLING EXISTING NOSKFOUNDATION, REFFR TO ENGINEERING DRANMG6
PROVIDED BY THE M4IUFACTURER FOR KIOSKMOOELS%9 DAMDO1rzVAID FOR
DESIGN CRITERIA STRUCTVRGLENGINEEGMANCHORINGGND ELECTRICAL
REOUIREMEMS.
BUILDING CODES
6IKPI EOITNIN FLORIDA BVILDING CODE M171- E%ISPNG BUILDING
G . EORION " OGTDA BUILDING CODE Min - BUILDING
SIXM EDITION FLORIDA DUI -DING CODE Mm • ACCESS iBlury
MI NATION& EUECTRICAL CODE-NFPAM
SI M EDITION FLORIMME PREYENPON CODE
O EG NEI
Az WIND DESIGN DATA
GXr T ,65W CIRCUIT65 CIGCUIATEOPERASC PER WNEO SNE
CIRCUITS! ULPMGTEDESIGN VANDSPEEO:24 m
_ NGSOATEG61GNVNIO SPEED:1]AmP'A
RISKGTEGORY:II
Al ONE -LINE ELECTRICAL DIAGRAM I
e PROJECT NOTES
SCALE: A+ SCALE:
rc
E x
and
c rn m
LL
��y 3
U m YUS
It
C
a. NO w`
>Y �
N
EQ
a
Al
FRONT ELEVATION
Al SCALEt 1/2` a 1'-0"
TOP VIEW
112 1
a a
Ll
47 3/8" X 22 3/4"
SIGN SIZE
�— 58 1/4"�I
FRONT VIEW
THE INFORMATION CONTAINED IN THIS DRAWING IS
COPYRIGHTED. ANY REPRODUCTION IN PART OR WHOLE
WITHOUT WRITTEN PERMISSION IS STRICTLY PROHIBITED.
/8"
I
Model # 3868
Drive -Up Island Identifi
Features:
*Backlit Front Sign
*Network & Graphic Display Areas
*Canopy Downlighting
*Secure Storage
*Ventilation Duct For ATMs With A.C.
�-- 31 7/8" --
SIDE VIEW
COMPANION
6 5
4 3
2 1
FRONT SIGN LED LIGHT ASSY.
0
A
o ' @6�689069' , E I
c 8C0<ID(IOVEM
I II
0
A11
EQUIPMENT CABINET WITH ELECTRICAL BOX
DIGITAL TIMER FOR L
CANOPY DOWN LIGHTS
12V LOW VOLTAGE CABLES !
OUT TO LED SIGN \ll
LIGHTING L
120V/ 12V TRANSFORMER
FOR LED SIGN LIGHTS L
i
120V 12-2 MC CABLE
WITH GROUND L
OUT TO CANOPY DOWN LIGHTING
L
L
NEUTRAL —
CIRCUIT I _
30A 120V
GROUND
NOTES:
1. ELECTRICAL ACCESS TO KIOSK SHOULD BE FROM BELOW GROUND LEVEL OR FROM EXISTING OVERHEAD
2. ALL CIRCUITS CONSIST OF 1/2" METAL CONDUIT PREWIRED WITH TWO THHN CONDUCTORS AND ONE THHN GROUND. (SEE LOAD CHART FOR WIRE SIZE)
3. ALL WIRING OVER CURRENT PROTECTION AND CLEARANCE SHALL COMPLY WITH LOCAL CODES AND APPLICABLE VERSIONS OF THE N.E.C.
4. ELECTRICAL CONNECTION IS MADE TO THE MAIN DISCONNECT AT THE SITE
S. ALL ELECTRICAL COMPLONENTS SHALL BE MOUNTED AND WIRED PER THE NATIONAL ELECTRICAL CODE AND PER MANUFACTURED REQUIREMENTS.
ELECTRICAL LOAD CALCULATIONS
CIRCUIT If
DESCRIPTION
CALCULATED LOADS & CIRCUIT
REQUIREMENTS
BREAKER SIZE
kVA
WIRE SIZE
1
DEDICATED ATM CIRCUIT
(CONNECTED DIRECT TO ATM)
16A-2 WIRE 120V
30A
1.92
IOAWG
(I) GENERAL PURPOSE DUPLEX
2
(1) GFCI DUPLEX
L.E.D. SIGN LIGHTING
7.08A-2 WIRE 120V
20A
0.85
12AWG
CANOPY DOWNLIGHTING
TOTAL kVA
2.77
THE INFORMATION CONTAINED IN THIS DRAWING 6 THE SOLE PROPERTY OF COMPANION SYSTEMS. ANY REPRODUCTION IN PART OR
6 5 4
41NCH FANS
U,W
W1.)1P
a
WRITTEN PERMISSION OF COMPANION SYSTEMS 6 PROHIBITED.
3
DUPLEX OUTLET
DUPLEX OUTLET
GEPS 12-60
-----
—��
T 120V 12-2 MC CABLE
WITH GROUND
INTO KIOSK
8 FEET LONG
DETAIL A
SCALE 1 : 4
NEUTRAL
CIRCUIT 2
20A 120V
GROUND
U
w
w
T
12V LED
SIGN LIGHTING
41
c
I
FAN
CANOPY DOWN
LIGHTING
A
IMlE55 OINEIfN6E
:�° °�
"�
I.ARE:
COMPANION
•SI16
�NG�1
v SSI
APPROVALS
DATE
3868 Electrical Details
ENGNEERED: ANC
0IM/IB
DRAWN: ANC
01/W/IB
CHKYFD: BH
Ol/09/18
sxEn
g
Rad.1D-ORW LYFe,EeoMed componen1,5e9eenceR
3868 Electrical Layout
REVBION
A
ANGLE
SCAIE=18
PRO EC11DN
W NOi SCALE
665WF5=ERMH - EROM s tAEZOIAHe RAR. TEIERNJNER I®n.z I SHEET: 1 of 1
is