HomeMy WebLinkAboutBUILDING PLANSRECFTVFn FEB ST. Lucie Cc GENERAL STRUCTURAL NOTES: GENERAL: ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE 2017 FLORIDA BUILDING CODE. ALL GLAZING SHALL BE NON -IMPACT RATED AND SHALL BE SHUTTERED. ALL WINDOWS TO BE INSTALLED PER NOA AND THE MANUFACTURER'S RECOMMENDATIONS/SPECIFICATIONS. LOADINGS: WIND LOADS: ULTIMATE WIND SPEED, 3 SECOND GUST: 16S MPH BUILDING CATEGORY: II EXPOSURE CATEGORY: D INTERNAL PRESSURE COEFFICIENT: +/-0.18 WINDOW SCHEDULE ST. LUCIE COU\" I'Y REVIEWED FOR CC DATE YL.- rNb AArl) YEHMIT M ST BE KEPT ON JQB. OR NO INSPECTION WILL BE NtkDE, THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH Aµ APPWQ Akq se0691 CONCFXED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILTfY OF THE CONTRACTOR OF RECORD SIZE DESIGNATION TYPE GLASS ACTUAL WIND PRODUCT DESIGN (WXH) DESCRIPTION PRESSURE(ASD) PRESSURES, PSF 36°X48° SINGLE HUNG SH NON -IMPACT +46.4 +55 _g1.8 WINDOW -61.5 35"X48° PICTURE PIN NON -IMPACT +46.4 +65 WINDOW -61.5 -66 [CATES WINDOW TO BE REPLACED IN EXISTING NING-SEE SCHEDULE OW REPLACEMENT PLAN NTS voo ,.SUMMIT DESIGN & FORENSICS, INC. ns SE MKT 5]. LUCM Mm. S mSl MKT Sf. Lum MDO pn) 28sosn 3 0 0 z i o.T oEs�Grreo oL.,sv ern N G= GMW CXEC%ED 70i N0. 2018-006 S-1