Loading...
HomeMy WebLinkAboutWIND PRESSURE CHART,r BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A• CLADDING (P.S.F.) FOR ASCE 7-10 - PEAK ROOF HE/GHT LESS THAN OR EQUAL TO dO FEET aK BASIC WIND SPEED = 170 mph RISK CATEGORY l! BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L' LESS THAN 7'-9' L- GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3' La' GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSmVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. O' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 1 51.8 > 15'-20' 80.4 48.2 f076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25-30' 86.2 51.7 115.5 69.3 82.4 49.4 1077 64.6 773 46.4 974 58.4 > 3O'-40 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > So'-6o' I 973 1 58.4 1 130.3 1 78.2 1 92.9 1 55.7 1 121.5 1 72.9 1 87.2, 1 52.3 f09.9 65.9 BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS do CLADDING (P S F,) FOR AiCE 7- f 0 - PEAK ROOF HEIGHT GREATER THAN 60 FEEf aK BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) SCANNED By St. Luce Coun!, ST. LUC ��UNTI �BIL N% DIVISIO REVIEWED FOR COMPLIANr-E REVjZlVrLD BY C DATE PLANS Alm PERMIT MUST BE IC;LPT O OR NO INSPECTION WILL BE hIADE. PEAK ROOF L•• LESS THAN 12-3' L- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 167.7 100 84.3 50.6 148.4 89.0 - a0' 93.6 56.2 171.E 103.0 86.2 51.7 151.9 91.1 >- - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90, - 100' 97.3 58.4 178.4 1074 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 978 - 140' 103.2 61.9 189.2 113.5 95.1 57.1 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - 180' 1078 64.7 197.6 , 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63. 1 185.1 111.1 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 126.4 75.8 231.8 1139.1 116.5 69.9 205.1 123.1 _ 128.8 1 77.3 1 136.1 1 141.7 1 118.6 1 71.2 1 208.9 125.3 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES 15 COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SUE SPECIFIC PROJECT. 2.) THIS W/ND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER /F USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND AS.D. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED /NVAUD IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR. PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/ZAKE OFF SHEET, ETC). * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. K PRODUCTS WHICH BEAR A M14Ml-DAOE COUNTY OR A STATE OF FLORIDA APPROVAL PE pf l0 i 0! �E�L Q%U LZENsf to. A' • �cMIE 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCI£ & INDIAN RIVER COUNTIES ASCE 7-10 / WIND PRESSURE CHART LC STORM PANELS, ACCORDION & B4H4M4 SHUTTERS *** DRAWN BY RISK GAT. II BLDGS 08109117 L E C O INC. WIND PRESSURE CHART DATE F TESTING & ENGINEERING COMPANY BASIC WIND SPEED = 170 mph 17- 194 W. J6N. 5t. Ste. JGS NRGING G9RDEN5 Fl. JJr66 EXPOSURE D, Kd = 0.85 6m• : (Josfan-rsTG . r : (Jas)en-rvr DRAWING No EB-0006719 "ry A0 °�V mrz tay. x, oauviex mrz WALTER A TILUr Jr. P.E r an rs-rea /r a SHEET I OF I FLORIDA Ga If 44167 1 2 1 11_1 4