Loading...
HomeMy WebLinkAboutSERVICE AGREEMENT4AMM OWN MA THEIRS ENGINEERING CORPORATION SERVICE AGREEMENT AMOUNT: $Time & Materials PAYMENT TERMS TO THE PROVIDER OF SERVICES: • Inspections to be billed on a time and material basis And invoice to be billed weekly and paid with 10 days of receipt. (Rates as per Schedule B) 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 $Time and Material Basis To accept this proposal, please sign and initial where indicated. Please return the original Service Agreement to our office along with a check for the retainer. This proposal is valid for 20 days. (Provider of Services) William J. Mathers, President Mathers Engineering Corporation RECEIVED JAN 18 2019 ST. Lucie County, Perh)1t€i11c,� Accepted by: Atrium II Condominium Association, Inc. (Client) Print Name: oers Notary State Florida Shannon on OOr 'Donnellll 9 ar M1 120222 ffi MY zaea SCANNED BY St. Lucie County CLIENT INITIALS: 1 0`11 2 OWN MATHERS ENGINEERING CORPORATION ATTACHMENT "B" MATHERS ENGINEERING CORPORATION RATE SCHEDULE — EFFECTIVE JANUARY 1.2018 UN 1' ; PROFESSIONAL ENGINEER ENGINEER INSPECTOR ENGINEER I PROJECT MANAGEMENT ARCHITECT I COMPUTER DESIGN & DRAFTING ADMINISTRATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 $ 150/hr $ 145/hr $ 135/hr $ 95/hr $ 95/hr $ 95/hr $ 75/hr $ 55/hr TIME & MATERIAL POLICY The Company Policy regarding payment of Time and Material Engineering Work is as follows: All Invoices must be paid prior to: (A) County or Agency Submittals, (B) The release of Plans Signed or Unsigned, (C) Final Certifications. NOTES: (1) Principal Time may be figured upon a percentage basis. (2) Site Inspections are a Minimum of One (1) hour chargeable time; Time includes travel to and from site. (3) Subcontractor Costs will be Invoiced at direct cost plus 10% fee. (4) Expert witness fees for above fields the hourly rate is doubled. JAN r 8 r,819 ST. Lucie County, Permitting - NI CLIENT INITIALS: Y 3 OWN MATHERS ENGINEERING CORPORATION 1. DEFINITIONS STANDARD PROVISIONS 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 a. "Client" shall mean the person, owner, firm., or corporation for whom the Services are to be performed, identified on the face of this Service Agreement. b. "Provider of Services" shall mean the Company named on the face of this Service Agreement and will herein be known and called the "Provider of Services". C. "Client Order" shall mean the purchase order, request, authorization (written or verbal), or other notification and addition or modification thereto whereby Client indicates its desire that Provider of Services famish services. d. "Provider of Services Proposal" shall mean the letter, proposal, quotation, or other notification, including any response to a Client Order, wherein Provider of Services offers to furnish services and to which these Standard Provisions are attached. e. "Services" shall mean the services described in the Provider of Service's Proposal, Attachment "A", or Client Order and any other services as may be added to or performed in connection with this contract. f. "Contract" shall mean this Service Agreement and the Standard Provisions, and the Provider of Services Proposal, and shall include, only to the extent not inconsistent with any aspect of the Provider of Services Proposal and these Standard Provisions, the provisions of the Client Order. 2. EQUIPMENT AND ACCESS TO SITE Provider of Services will provide the specialized portable test equipment required for those items under the Scope of Services which involve field testing. Client will provide Provider of Services with access to all facilities involving field survey services and will make available for Provider of Services use such as maps, drawings, and records as are needed for the proper conduct of the Services. Construction supervision by the Provider of Services is deemed to be part of this contract at the option of the Provider of Services. Non-compliance with this paragraph shall render the plans null and void. The Construction Phase will commence with construction at the site and will terminate when the final certification is given by the Provider of Services. 3. BILLING Unless specified otherwise in the Provider of Services Proposal, Provider of Services shall be compensated as follows: a. Unless otherwise stated in the Service Agreement portion of this contract the Time and Material rates charged are those contained in Schedule "B". These rates may be increased during the term of this contract within sixty (60) days of written notification by Provider of Services to the Client. In addition to payments provided for the services rendered, Client shall pay Provider of Services actual costs of all reimbursable expenses including but not limited to, blueprinting, plotting, messenger fees, mileage, postage, including express mail fees, etc.. Reimbursable expenses are defined as out-of-pocket expenses incurred by the Provider of Services in connection with the project for all basic and additional services and supplies. b. Provider of Services invoices are rendered monthly and are payable upon receipt unless modified by provisions in the Service Agreement signed by the Client and Provider of Services. Invoices past due ten (10) days shall bear and incur interest at the rate of 1.5%per month from the billing due date. Client shall notify Provider of Services in writing within 5 days of receipt of any disputed charges. Both parties will promptly resolve the disputed portion of the charges and the Client agrees to promptly pay the resolved amount of the disputed portion. Client shall be considered in default of this Agreement, if CLIENT INITIALS: !/ OWN MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 C. Provider of Services does not receive payment in full for invoiced services with ten (10) days of invoice date. Upon default, Engineer may suspend or terminate services under this Agreement, without incurring any liability or suspension or termination. it. The Client is the owner of the previously described property or warrants that he/she has obtained the owners written consent and agreement that any, and all further owners, of said property shall take title pursuant to the Standard Provisions of this Contract. e. If any invoice or portion thereof remains unpaid more than sixty (60) days following invoice date, the Provider of Services may initiate legal proceedings to collect same including all legal, employee, and office expenses incurred. In the event Provider of Services liens the property and/or hires an attorney to collect Provider of Services' fees, Client agrees to pay reasonable attorney's fees for collections, trial and appeal, including, all costs and interest. The venue of legal proceedings shall be Martin County, Florida. f. The Client acknowledges and agrees that the payment for services rendered and expenses incurred by the Provider of Services pursuant to this agreement is not subject to any contingency unless the same is set forth in the Service Agreement portion of this contract. RESPONSIBILITY FOR SERVICES a. Indemnification: Client shall, to the fullest extent permitted by law, indemnify, defend and hold Mathers Engineering Corporation and Mathers Engineering Corporation's officers, directors, professionals, partners and employees, and any of them (collectively for this entire Section as to "Provider of Services"), harmless against all claims, suits, fines and penalties, including attorneys fees and costs of settlement and defense, which such liabilities arise out of or are related to this Agreement or Services, except to the extent that they are caused solely by Provider of Services' negligent or willful misconduct. Such compensation shall be based upon Provider of Services' prevailing fee schedule and expense reimbursement policy. Limitation of Liability: TO THE FULLEST EXTENT PERMITTED BY LAW, AND NOTWITHSTANDING ANY OTHER PROVISION OF THE SERVICE AGREEMENT OR THESE STANDARD TERMS, AND CONDITIONS, THE TOTAL LIABILITY, IN THE AGGREGATE, OF PROVIDER OF SERVICES, TO THE CLIENT AND ANYONE CLAIMING BY OR THROUGH THE CLIENT, FOR ANY AND ALL CLAIMS, LOSSES, COSTS AND EXPERT WITNESS FEES AND COSTS OF ANY NATURE WHATSOEVER OR CLAIMS EXPENSES RESULTING FROM OR IN ANY WAY RELATED TO THE PROJECT OR THE SERVICE AGREEMENT FROM ANY CAUSE OR CAUSES SHALL NOT EXCEED THE HIGHER OF THE (i) TOTAL COMPENSATION RECEIVED BY PROVIDER OF SERVICES UNDER THE SERVICE AGREEMENT OR (ii) THE TOTAL AMOUNT OF $6,000.00. 1T IS INTENDED THAT THIS LIMITATION APPLY TO ANY AND ALL LIABILITY OR CAUSE OF ACTION HOWEVER ALLEGED OR ARISING, WHETHER CAUSED BY PROVIDER OF SERVICES' NEGLIGENCE, INCLUDING ERRORS, OMISSIONS, FOR OTHER ACTS OR FOR ANY DAMAGE BASED IN CONTRACT, OR FOR ANY OTHER CAUSE OF ACTIONS, UNLESS OTHERWISE PROHIBITED BY LAW, AND CLIENT SHALL INDEMNIFY AND HOLD PROVIDER OF SERVICES HARMLESS FROM ANY SUCH DAMAGES OR LIABILITY. b. In the course or performance of its Services, Provider of Services may rely upon information supplied by Client or Client's contractors or consultants, or information available from generally accepted reputable sources without independent verification. c. The Client assumes all the responsibility for construction site safety, the Provider of Services shall not be responsible for construction site safety. d. No guarantee is expressed or implied for the action of government officials to provide the desired approvals. CLIENT INITIALS: 1//0 MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 e. In the event litigation in any way related to the services performed hereunder is initiated against the Provider of Services by the Client, its contractors, or subcontractors, and such litigation concludes with the entry of a final judgment favorable to the Provider of Services, the Client shall reimburse the Provider of Services for all of its reasonable attorney's fees and other expenses related to said litigation. Such expense shall include, but not be limited to, the cost, determined at the Provider of Services' normal hourly billing rates, of the time and direct expenses devoted to the defense of such litigation by Provider of Services employees. If Client maintains all of builders risk or other physical damage insurance, whether direct or indirect, including but not limited to boiler, machinery, fire, and outage insurance, or enters into a so-called "wrap-up" insurance agreement, Client agrees to waive all rights of recovery against Provider of Services with respect to loss or damage which is covered by such insurance coverage. Client also waives all liability Provider of Services arising from loss of or damage to property of Client, and further agrees to indemnify Provider of Services against all such liability, whether or not such loss or damage is covered by insurance policies maintained by Client and whether or not such loss or damage results or is alleged to result from the fault or negligence, including sole negligence, of Provider of Services. g. Performance by Provider of Services of any quality assurance or vendor quality assurance services shall in no way constitute an assumption by Provider of Services of any, or relieve a contractor, manufacturer or supplier from full responsibility for delivery of all services, materials, equipment, and documentation in strict accordance with the requirements of the contractor, manufacturer, or supplier/Client purchase contract. h. Drawings and Specifications as instruments of service are and shall remain the property of the Provider of Services whether or not the Project for which they are made is executed. They are not to be used by the owner on other projects or extensions to this Project except by agreement in writing and with appropriate compensation to the Provider of Services. i. Client agrees that the bylaws, or other governing documents, of the homeowners/condominium association will require the association to perform, as recommended in their association documents and maintenance manuals, all routine maintenance, inspections and other necessary repairs and maintenance called for as a result of these inspections. The bylaws should also contain an appropriate waiver and indemnity in favor of Provider of Services and the contractor if the recommended maintenance services are not performed. INSURANCE a. During the course of performance of the Services, Provider of Services will maintain for the protection of Provider of Services and its employees. Workers' Compensation and Employers' Liability, and Comprehensive General Liability. b. If requested by Client, Provider of Services shall deliver to Client certificates of insurance completed and will not be cancelled or materially changed until thirty (30) days after written notice is given to client. DELAYS Neither party shall be considered in default in the performance of its obligations under this Contract to the extent that the performance of such obligations is prevented or delayed by any cause beyond the reasonable control of the affected party, and the time for performance of either party hereunder shall in such event be extended for a period equal to any time lost as a result thereof. CHANGES AND TERMINATIONS Client shall have the right to make changes within the general scope of the Services upon execution of a mutually accepted change order. Client shall also have the right to terminate this Contract prior to completion of the Services, after reasonable notice to Provider of Services in writing, in which event Client shall pay Provider of Services all amounts due Provider of Services hereunder up to the effective date of termination, plus Provider of Services' reasonable costs incurred after such date in terminating the Services. CLIENT INITIALS: V P MATHERS ENGINEERING CORPORATION 8. CERTIFICATE OF MERIT 9. 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 The Client shall make no claim for professional negligence either directly or by way of a cross complaint against the Provider of Services (Consultant) unless the Client has first provided the Consultant with a written certification executed by an independent consultant currently practicing in the same discipline as the Consultant and licensed in the State of Florida. This certification shall: a) contain the name and license number of the certifier; (b) specify the acts or omissions that the certifier contends are not in conformance with the standard of can for a consultant performing professional services under similar circumstances; and c) state in detail the basis for the certifier's opinion that such acts or omissions do not conform to the standard of care. This certificate shall be provided to the Consultant not less than thirty (30) calendar days prior to the presentation of any claim or the institution of any arbitration orjudicial proceeding. This Certificate of Merit clause will take precedence over any existing state law in force at the time of the claim or demand for arbitration. If the Project or the Consultant's services are suspended by the Client for more than thirty (30) calendar days, consecutive or in the aggregate, over the term of this Agreement, the Consultant shall be compensated for all services performed and reimbursable expenses incurred prior to the receipt of notice of suspension. In addition, upon resumption of services, the Client shall compensate the Consultant for expenses incurred as a result of the suspension and resumption of its services, and the Consultant's schedule and fees for the remainder of the Project shall be equitably adjusted. If the Consultant's services are suspended for more than ninety (90) days, consecutive or in the aggregate, the Consultant may terminate this Agreement upon giving not less than five (5) calendar days' written notice to the Client. If the Client is in breach of the payment terms or otherwise is in material breach of this Agreement, the Consultant may suspend performance of services upon five (5) calendar days' notice to the Client. The Consultant shall have no liability to the Client, and the Client agrees to make no claim for any delay or damage as a result of such suspension caused by any breach of this Agreement by the Client. Upon receipt ofpayment in full of all outstanding sums due from the Client, or curing of such other breach which caused the Consultant to suspend services, the Consultant shall resume services and there shall be an equitable adjustment to the remaining project schedule and fees as a result of the suspension. 10. DELAYS The Client agrees that the Consultant is not responsible for damages arising directly or indirectly from any delays for causes beyond the Consultant's control. For purposes of this Agreement, such causes include, but are not limited to, strikes or other labor disputes; severe weather disruptions or other natural disasters or acts of God; fires, riots, war or other emergencies; failure of any government agency to act in timely manner; failure of performance by the Client or the Client's contractors or consultants; or discovery of any hazardous substances or differing site conditions. In addition, if the delays resulting from any such causes increase the cost or time required by the Consultant to perform its services in an orderly and efficient manner, the Consultant shall be entitled to a reasonable adjustment in schedule and compensation. it. CODE COMPLIANCE The Provider of Services shall put forth reasonable professional efforts to comply with applicable laws, codes and regulations in effect as of the date of the execution of this Agreement. Design changes made necessary by newly enacted laws, codes and regulations after this date shall entitle the Provider of Services (Consultant) to a reasonable adjustment in the schedule and additional compensation in accordance with the Additional Services provisions of this Agreement. CLIENT INITIALS: OWN MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 12. PRECEDENCE AND DIVISIBILITY The provisions of the Provider of Services Proposal and these Standard Provisions shall fully govern any Services furnished by Provider of Services and shall prevail over and render void any inconsistent or conflicting provision of the Client Order. If any term, condition, or provision of this Contract is declared void or unenforceable, or is limited in its application or effect, such event shall not affect any other provision hereof and all other provisions shall remain fully enforceable. 13. ENTIRE AGREEMENT This contract contains the entire agreement between the parties as to the Services rendered hereunder. All previous or contemporaneous agreements, representations, warranties, promises, and conditions relating to the subject matter of this Contract we superseded by this Contract. 14. GOVERNING LAW Unless otherwise provided, the substantive law of the State of Florida will govern the validity of the Service Agreement, its interpretation and performance, and remedies for contract breach or any other claims related to this Agreement. 15. ASSIGNS The Client may not delegate, assign, sublet or transfer his, hers or its duties, obligations or interests in the Service Agreement without written consent of Provider of Services. CLIENT INITIALS:_ 10 KEYSTONE ENGINEERING & CONSULTING,, INC. Progress Inspection Report #10 Permit# 1gIa.- oa13 Project Name: Atrium II Progress Report thru 4-26-19 Project Address: 3000 N Highway AIA, Ft Pierce Inspection Visits: 4-24-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack swing stage removal and A stack swing stage rigging; SGD blockades and protection; A stack mark out and demo INSPECTORS REPORT Keystone Engineering visited the site on 4-24-19 and also had several conversations with the construction team by telephone throughout the week. The swing stage has been removed from the D stack balconies and was rigged on the A stack early in the week. Sliding glass door blockades were rigged and protection will be rigged in work areas as excavations progress on the A stack. On Wednesday morning, areas were marked for repair on the A stack balconies. Slab edge excavations were in -progress on the Unit 2A balcony Wednesday afternoon, scheduled to continue on remaining floors next week. James E. Emory, P.E. KEYSTONE 8vGINi ERING & CONSULTING, INC. Progress Inspection Report #11 Permit #1812-0223 Project Name: Atrium II Progress Report thru 5-3-19 Project Address: 3000 N Highway AlA, Ft Pierce Inspection Visits: 5-3-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: A stack demo, formwork, reinforcing steel detail, pre -pour, rust spots, stray steel removal and grease cap repairs INSPECTORS REPORT Keystone Engineering visited the site on 5-3-19 and also had several conversations with the construction team by telephone throughout the week. On the A stack balconies, slab edge and surface excavations have been wrapped up on all floors. Form construction and existing reinforcing steel detailing was being wrapped up Friday on the A stack repairs. Rust spot excavations also remain in -progress on the A stack balconies, scheduled for completion next week. A pre -pour inspection was completed Friday morning on the A stack balcony repairs and minor additional areas were marked for excavation prior to casting. Stray steel was also marked for removal and post tension anchor pockets requiring cable trimming and grease cap removal/replacement were marked for repair. Post tension cable grease cap repairs are scheduled to begin next week. James E. Emory, P.E. I I t 9 S a j r." y OVAa. ^Lr r ;I a n excavation where reinforcing steel corrosion continues c� C �} f 0 Gr.J n� O C,; co C� �,/� ' 2431 —E.- uixie Hwy Stuart, FL 34996 OWN r� Phone: (772) 287-0525 MATHERS ENGINEERING D Email: mathersengineers@bellsouth.net CORPORATION JUN, 0 � 2019 Memo By To: William Durden, Reviewer From: Holly Mathers Co: St Lucie Co. Building Dept. 2300 Virginia Avenue Fort Pierce, FL 34982 Fax: Pages: SEE ATTACHED Date: 05/29/2019 Re: Atrim II Condominium Phone: 3000 N. Highway Al A, Fort Pierce, Concrete Restoration Permit #Slb M5002 ❑ Please Reply X Mailed ❑ Nand Delivered ❑ Faxed Only ❑ Faxed and Mailed Enclosed is 1 signed and sealed threshold engineer's field observation report #2 for the concrete restoration permit #SLC 1812-0223 for Atrim II Condominium (Stack D). Thank you, Holly This message is intended only for use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of the message is not the intended recipient, or the employee or agent responsible for delivering the message, you are hereby notified that any dissemination, distribution or copying of the communication is strictly prohibited. If you have received this communication in error, please notify us immediately by telephone and return the original message to us at the address above via the U.S. Postal Service. A W W9 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 MATHERS ENGINEERING EB#0004456 CORPORATION Post -Building Permit Addendum Engineer's Field Observation Report #2 Date: May 29, 2019 To: Plan Reviewer St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Contractor: Structure -Con PO Box 2626, Okeechobee, FL 34973 Engineer of Record: James E. Emory, P.E. Keystone Engineering & Consulting 166 Center Street Suite #210 Cape Canaveral, FL 32920 Referenced Project: Concrete Restoration for Atrim II Condominium Stack D 3000 N. Highway AlA, Fort Pierce, Florida 34949 Permit #1812-0223 Mathers Engineering Corporation visited the job site and made the following observations of the ongoing concrete restoration and repairs of exterior balconies in progress: Site Observations from 04/04/2019 to 04/18/2019 Stack D: • Unit D2: Chipping, deck repairs and post -tension repairs are completed. • Unit D3: Chipping and deck repairs are completed. • Unit D4: Chipping and deck repairs are completed. • Unit D5: Chipping and deck repairs are completed. • Unit D6: Chipping and deck repairs are completed. • Unit D7: Chipping, deck repairs, edge repairs and post -tension repairs are completed. • Unit D8: Chipping, deck repairs and ceiling edge repairs are completed. • Unit D9: Chipping and deck repairs are completed. • Unit D10: Chipping and deck repairs are completed. • Unit Dll: Chipping and deck repairs are completed. • Unit D12: No concrete restoration performed. Only rust spots and stucco repair in small area. Our final observations were performed for Stack D repairs. Repairs were completed in general conformance with the Engineer of Record plans as well as any field modifications required after demolition. 1�Page MATHERS ENGINEERING CORPORATION 2431 SE Dixie Highway Stuart, FL 34996 Phone: (772) 287-0525 EB#0004456 Limitations: Our professional services have been performed, our findings obtained and our opinions prepared in accordance with general accepted engineering principles and practices as well as coordination with the Engineer of Record for field modifications. This company is not responsible for the conclusions, opinions or recommendations made by others based on our findings. Approved by: William J. Mathers, PE Florida License PE #19658 Florida SI #155 �\1111 I I I ///// ���PNI J. MqT ,,\CENSF Pl� 19658 co (�� * *� i STATE OF •� � \ /FSS oNA i ENG� \�� 21Page OWN MATHERS ENGINEERING CORPORATION Memo 2431 SE Dixie Hwy Stuart, FL 34996 Phone: (772) 287-0525 Fax: (772) 220-8686 Email: mathersengineers@bellsouth.net To: Plan Reviewer From: Holly Mathers Co: St Lucie Co. Building Dept. Pages: SEE ATTACHED P 2300 Virginia Avenue Fort Pierce, FL 34982 a`d Fax: Date: April 08, 2019 Re: Atrim II Condominium Phone: 3000 N. Highway A1A, Fort Pierce Concrete Restoration Permit #1812-0223 ❑ Please Reply X Mailed ❑ Hand Delivered ❑ Faxed Only ❑ Faxed and Mailed Enclosed is 1 signed and sealed engineer's field observation report # 1 for the concrete restoration permit #SLC 1812-0223 for Atrim II. Thank you, Holly This message is intended only for use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. If the reader of the message is not the intended recipient, or the employee or agent responsible for delivering the message, you are hereby notified that any dissemination, distribution or copying of the communication is strictly prohibited. If you have received this communication in error, please notify us immediately by telephone and return the original message to us at the address above via the U.S. Postal Service. • � t 2431 SE Dixie Highway Stuart, FL 34996 MATHERS ENGINEERING Phone: (772) 220--8686 CORPORATION Fax: (772) 220666 EB#0004456 Post -Building Permit Addendum Engineer's Field Observation Report #1 Date: April 08, 2019 To: Plan Reviewer St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Contractor: Structure -Con PO Box 2626, Okeechobee, FL 34973 Referenced Project: Concrete Restoration for Atrim H Condominium Suck D 3000 N. Highway AlA, Fort Pierce, Florida 34949 Permit #1812-0223 Mathers Engineering Corporation visited the job site and made the following observations of the ongoing concrete restoration and repairs of exterior balconies in progress: Site Observations from 02/26/2019 to 04/03/2019 Stack D: • Unit D2: Chipping is underway for partial depth deck repairs; tension bars 12 qty. under repairs. • Unit D3: Chipping is underway for partial depth deck repairs. • Unit D4: Chipping is underway for partial depth deck repairs. • Unit D5: Chipping is underway for partial depth deck repairs. • Unit D6: Chipping is underway for partial depth deck repairs m progress. • Unit D7: Chipping is underway for partial depth deck repairs, edge repairs and tension bars 18 qty. Full depth deck edge repair area chipping in progress. • Unit D8: Chipping is underway for partial depth deck repairs and ceiling edge repairs. • Unit D9: Chipping is underway for partial depth deck repairs. • Unit D10: Chipping is underway for partial depth deck repairs. • Unit Dll: Chipping is underway for partial depth deck repairs. Limitations: Our professional services have been performed, our findings obtained and our opinions prepared in accordance with general accepted engineering principles and practices. This company is not responsible for the conclusions, opinions or recommendations made by others based on our findings. Approved by: I/, William J. Mathers, PE Florida License PE #19658 Florida SI #155 \\���\11 I I M //// ��� = PE 19658 ' N * , � STATE OF .'�� O '•-tORIO���� S/ONA11OG\��� f "�'' l+ CLJ-L:fi ------------------ u F� - r--------�--- --- - - z r _.___� r -.._ .. - � - „ x ram. �� �_ „� ... z. _ ... . _ _ `z��_ y__ ., `� _� .�.. �„� � Aw `. .. _ _ � f�, rMO�i'iGGGG :'■GG000GGGGG■Yi� ■ SY■■N■ ■■■■ ■ ■ � e m G� �� a S■� ■ N ■q ■ 'i■'■'uiC'�ni"C�n■n■■�nii ■■■cam =�i. .. 1 C.�'i■ Y =..oM.S■.: ■:muSE .. ...n .Y� :'C SHO N■ ■■NSORS=.■■■■■■ p p. .:N �.pN�= pp■■nn■■■■■■■■uNY■N.■ YYCIIp ■■■■ .N N■�01�0■a�'q ■nEM • • !■■■nu ■vaYY■1! ME ■ ■ ■■■� ■■■N■■■■■SNNNEN� MEMO■ M■■ ■NNN■■ �■■■ ■ ■■ ■Sm M■Wn■■■ ■M ■ MOM ■��'�■ mom �� ■!■:■: ■■ ■■::Y�uY ■■NAN'■�■' i■e■ iS■■MMN■■S■■■■u■■S ■■■S■■S■m■ NONE �■W: ::: : no man :::::m:::ig:':M0 ■.:C".11 EMs • .■■.■■m . NI I MR mom mom --M ■ii�■Ni■iiiiiiiiiiiiii A C! ■�niilMmMmmi■n■i:NOR iiimiiii■iiI =i■i■n iiiiiiiiii iiiiiiiiiiiiioi■iii�■i�iiiiiii■��■�iiiiii ■iii■ HUNEMMMMEN ME MEMO■:.' •:.:.' ME . r . " �..'.::: �:::u::m.':�C ::Ju NEE .'�on ammo■■■■ENOS■E■■■■■■ c e o■■■■■■C■N■■■S■■■SSSN■S■SSnS■■■■■m■iS IN .YSSNmN■SNn■n■■■SNS■u■■■n�■■■■■■MN■�■SSu�S■SSN■■SnS■S■S■■S■ OR so ME so A AMR An MEAN ME MESA SEENNEEMEME EEEEE=Mmmmnrmmm ME ■■■M■■■■■■NN■... iui�iiiiiiiiM■■S i®iiiii■iiiiui��iii iiiiINOMEM ii ONE NN■iiiiiiiAll niii■ MEN no Osumi mSSSmom SS■S■SNNi■SE■NENW■SN■ii■■■N■Ni■■■■■N■■■■■■■MESON■N■■■ ::::m u■S■uS■ ■■■■SSS■■S■S■■NSS■S■■S■ SS■■■■O■■M■■ ■ ■■S■■■u_iisom`ui�A ...._.■ ■m■■■ M■■N ■■SOMME IN m r r o r r . .. • YilfFiiiili■N■■■■1 ■■■N■■■ Al ■l.�M�M■ ■S■SS■■..■uEEMESS■SSSMY■MS■■■S■SS■■ ....::.............■SNN ■■■■■■■■ �0=001mono N■n■■■■■■ mommom MEMENSi iiii■iimosomi� i MEMOS ■■ :::� :m::� ::::::C:::::::::::C::::C:� :. ::::::::::::m ::C::.:::::::' ■Niii :�:': m: m:: :: C..........■..p........N...■ ■ENNE■■■i ME■E■N■� N N■iM■E�� M�■S■S■nSS■N::::■N■::::' ':H:::mm:::::::SN::::S■:■■N:■:5:::: ■ ■■■■�■.N■ . ■N■■N■■■. ■■■■■■■■■■■■■SSMS■■■■SS o ■NSSS■■Sn■■■■■■■■N■■■mS■u■S■■ _. MEE SSNSn■S■■uS■■■iC■SS■■. ■SNM■■E■■MM■■■■ENN■M ■■■MM■ ■■■SS■■■■■■nS■ ■■■■ ■■ S�EONS ■■ ■■ ■■■■■■■■■■■■■SS■N■■■■■■■■ ■■ENM■■ENEE■EN■SSSSN ■EMS SME ■ SS ■■■!■■M■■■■■E■O■NEEu■EN■ ■E■NOM■■S■N■■■■SSSSS■ ■ .. ■ SS ■SNSSS■S■S■■S■■N■N`■■SS ■■■■■■■■■■■■■■■■■■■■■■ ■ ■ ■■■■ ■NNE■■■■■■■■ o ; ■■■■■N■■■■■ ■E■■MMM■N■E■NE■NOMNE■S ■SS■M■SSS■SS■SEN■■■■■MM■■■■ o '' , N■■No 0=0mmmnmmmwmmmmm ANEMONES SN■■S■■SS■■■■SS■Y■■■S■■S■ ■■.■SSSN■S■■■■■SS■■m■■S■ ■SS■S■■S■■■■NSS■■■■■■■SEE■ ■SS■■■ ■■■■■■S ■N■■■■■MM■M■M■■M■■S■u=SM■ ■■■■■■■M■u■Mu■■■■■■■S■M■■■■■■ ■ O■■■M ■■■■■■■■■■■■■■■■n■■■M■!■■ ii■■■■■N■■■■■■■■■■■■■■■■■■N■■■ ■■ ■■■■■■■■■ ■■■■■NON■■u N■■■■■■■ii MENS■E■EE■E■■■• is ' ■■EN■■■■■■■ii on ■■■ ME MINIMUM ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■N■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■N■ KEYSTONE ENGINEERING & CONSULTING., INC. Progress Inspection Report #1 Permit# )q la-0aa3 Project Name: Atrium II Progress Report thru 2-22-19 Project Address: soon N Highway AlA, Ft Pierce Inspection Visits: 2-19-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: mobilization; pre -construction meeting; swing stage rigging; Unit 7D thru 12D mark out and demo INSPECTORS REPORT Keystone Engineering visited the site on 2-19-19 and also had several conversations with the construction team by telephone throughout the week. Mobilization was completed with a. swing stage, storage trailer, tools and materials now on the job site. The work area was fenced off and the swing stage has been rigged on the D stack balconies in preparation for slab edge repairs. A pre -construction meeting was held Tuesday morning and areas were marked .for repair on the Unit 7D through 12D balconies. Excavations are now in -progress on the 1) stack in order to expose post tension cable anchor heads and perimeter bursting bar steel to determine necessary post tension cable lock -off locations, scheduled for early next week. Areas will also be marked for repair on remaining D stack balconies next week. James E. Emory, P:E. �1111U1f��, No.60965 ' FILE Copy View of slab edge spall marked for repair on the Unit 9D balcony poso xa slal3o ynoi peat' u031eq pz muff aqj uo ne ai Jo; panjew pe s a pa gels io Maiq f. KEYSTONE ENGINEERING & CONSULTING, INC. Progress Inspection Report #2 Permit# 1 gi a- oaa.!) Project Name: Atrium II Progress Report thru 3-1-19 Project Address: 3000 N Highway AiA, Ft Pierce Inspection Visits: 2-26-19 Prime. Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: Unit 7D thru 12D demo, pre -pour and PT inspection; Unit 2D thru 6D mark out and demo INSPECTORS REPORT Keystone Engineering visited the site on 2-26-19 and also had several conversations with the construction team by telephone throughout the week. Initial slab edge excavations were completed from the swing stage on the Unit 7D through 12D balconies and a pre -pour inspection was finished Tuesday on repairs where post tension cable lock -offs are not required. On the Unit 7D balcony, .post tension cable lock -offs will be required on 10 north -south cables and 4 east -west cables in order to complete slab edge excavations. Post tension cable lock -off installations are scheduled to begin next week on the D stack balconies. Sliding glass door blockades were being rigged on Friday in order to restrict resident access, scheduled for completion next Monday. On Tuesday, areas were markedfor repair on the Unit 2D through 6D balconies and excavations are now in -progress. On the D stack initial slab edge excavations, excessive reinforcing steel with minimal coverage was found to be typical running outside of post tension cable bursting bars/anchor heads along slab edge. Excessive steel was marked for removal on the initial D stack excavations and will be re -inspected next week. James E. Emory, P.E. View of slab edee excavation completed on the Unit 11D balcony View of slab edge excavation completed on the Unit 8D balcony where PT cable end trimming is required to properly reinstall grease cap View of slab edge spall marked for repair on the Unit 6D balcony View of slab edge spall marked for repair on the Unit 2D balconv View of slab edge spall marked for repair on the Unit 2D balcony showing exposed reinforcing steel/PT anchor heads where PT lock -offs will likely be required ��/ 6101 g 0 J N�/' ������lu KEYSTONE ENGINEERING & CONSULTING, INC. Progress Inspection Report #3 Permit# 1gI a-oaa3 Project Name: Atrium II Progress Report thru 3-8-19 Project Address: 3000 N Highway A1A, Ft Pierce Inspection Visits: 3-4-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: Unit 2D thru 6D slab edge demo and initial inspection; SGD protection and blockades INSPECTORS REPORT Keystone Engineering visited the site on 3-4-19 and also had several conversations with the construction team by telephone throughout the week. Slab edge excavations are currently in -progress from the swing stage on the Unit 2D through 6D balconies and an initial inspection was completed on Monday. On the Unit 2D south elevation slab edge, 14 north -south and 4 east -west post tension cables will require lock- off/splice chuck repairs. Lock -off installations on the Unit 2D and 6D balconies are scheduled for completion next week. Sliding glass door blockades have been rigged on all balconies where work is being performed and sliding glass door protection was also rigged. Slab edge excavations on the D stack balconies north side are scheduled to begin from outriggers next week. James E. Emory, P.E. \\6-1/' `N_ No.60865 ; Z w : STATE F View of slab edge excavations in -progress on the Unit 6D south elevation where continued spalling behind PT bursting bars will require lock-off/splice chuck repairs offs are required :=� ..,.- �� --`c a - � =� - '� _'�.: � h� 4 `tLL�' + .; 1 l:y � f t c,. c:� KEYSTONE ENGINEERING & CONSULTING, INC. Progress Inspection Report #4 Permit# fgi2 -pa23 Project Name: Atrium II Progress Report thru 3-15-19 Project Address: 3000 N Highway AlA, Ft Pierce Inspection Visits: 3-15-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack slab edge and surface demo, Unit 2D and 6D PT lock-offs/de- tensioning and formwork INSPECTORS REPORT Keystone Engineering visited the site on 3-15-19 and also had several conversations with the construction team by telephone throughout the week. Slab edge excavations are wrapping up from the swing stage on the D stack balconies and on the Unit 2D east elevation slab edge, 14 north -south post tension cables and 4 east -west cables will require lock-off/splice chuck repairs. Shoring was rigged beneath the Unit 2D and 6D balconies and post tension cable lock -offs were installed. A single east -west and north -south cable on the Unit 2D balcony and single north -south cable on the Unit 6D balcony were fully de -tensioned to avoid excessive lock -off excavations. Form construction is currently in -progress on the Unit 2D and 6D post tension slab edge repairs. Slab edge excavations on the D stack balconies east elevation are currently in -progress from outriggers, scheduled to continue next week. Minor surface excavations are also currently in -progress on the D stack balconies and post tension cable splice chuck/anchor head installations are scheduled to begin next Thursday on the Unit 2D and 6D balconies. James E. Emory, P.E. 0\\\\\E 111111 r/I�,'/ Esws�'P�'%. No.B * = - '0 \ STAT OF %�� •.�LO LAP �� 0 JUU 0 5 Z019 KEYSTONE ENGINEERING & CONSULTING.,. INC. Progress Inspection Report #5 Permit# ) ,� I a-oaa3 Project Name: Atrium I I Progress Report thru 3-22-19 Project Address: 3000 N Highway AlA, Ft Pierce Inspection Visits: 3-21-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack slab edge and surface demo, Unit 2D and 7D PT splice chuck/anchor head install; formwork and stray steel removal INSPECTORS REPORT Keystone Engineering visited the site on 3-21-19.and also had several conversations with the construction team by telephone throughout the week. Post tension cable splice chuck and anchor head installations were completed on the Unit 2D and 7D balconies with 18 cables on the Unit 2D balcony repair and 15 cables on the Unit 7D balcony repair. Form construction and reinforcing steel installation were wrapping up late in the week on the Unit 2D and Unit 7D balcony repairs and a pre -pour inspection is scheduled for next week.. Remaining excavations were completed on the D stack balconies and stray steel removal is currently in-progreii. Form construction is also now in -progress on the D stack repairs and existing steel will be detailed next week in preparation for a pre -pour inspection, scheduled for next Wednesday. James E. Emory, P.E. `����`� �cewsF,Q•Q�i� No.60965 Ill I� V/jo —t� I AI—��ko I �V oo I AIII� NQ q= lu NiI P- P z"®r -`l7 I JUN ® 5 2019 KEYSTONE ` ENGINEERING & CONSULTING, INC. Progress Inspection Report #6 Permit# jgla-daa3 Project Name: Atrium II Progress Report thru 3-29-19 Project Address: 3000 N Highway A1A, Ft Pierce Inspection Visits: 3-27-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack formwork and reinforcing steel detail, supplemental reinforcing steel placement, pre -pour and casting INSPECTORS REPORT Keystone Engineering visited the site on 3-27-19 and also had several conversations with the construction team by telephone throughout the week. On the D stack balcony slab edge and surface repairs, stray steel removal was completed and existing reinforcing steel was detailed. Formwork was constructed and post tension cable grout pocket forms were set on slab edge repairs where lock-offs/splice chucks are not required. Final formwork and reinforcing steel detailing was also completed on the Unit 2D and 71D post tension cable repairs. A pre -pour inspection was completed on all D stack balcony repairs Wednesday. Minor work to post tension grout pocket forms was completed Wednesday and supplemental reinforcing steel was added to the Unit 2D slab edge/post tension cable repair during the pre -pour inspection in order to tie-in steel at the southeast corner using #4 rebar. Casting of all D stack balcony repairs was finished Wednesday afternoon in preparation for post tension cable re -tensioning, scheduled for next Tuesday. James E. Emory, P.E. /Z C EN No.60965 STATE OF : A 61OZ 9 0 Nnr m@010�L6 KEYSTONE ENGINEERING & CONSULTING, INC. Progress Inspection Report #7 Permit # I - I a.- O aa3 Project Name: Atrium II Progress Report thru 4-5-19 Project Address: 3000 N highway AlA, Ft Pierce Inspection Visits: 4-2, 4-5-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack formwork and reinforcing steel detail, supplemental reinforcing steel placement, pre -pour and casting INSPECTORS REPORT Keystone Engineering visited the site on 4-2 and 4-5-19 and also had several conversations with the construction team by telephone throughout the week. Post tension cable re -tensioning was completed Tuesday on 10 cables on the Unit 2D balcony and 7 cables on the Unit 7D balcony. A single de -tensioned east -west cable released at the splice chuck during re -tensioning Tuesday on the Unit 7D balcony and excavations were made to expose existing cable and reinstall the splice chuck. Lock -off areas where cable re -tensioning was completed were cast back Tuesday afternoon and re -tensioning of all remaining post tension cables on the Unit 2D and 7D balcony repairs was finished on Friday. Sheathing was installed over exposed cable/splice chucks and cable ends were burnt with grease cap installations now in -progress. On the D stack balcony slab edge repairs, formwork has been removed and post tension cable grout pocket forms were removed in preparation for grease cap installations and grout pocket filling. Drip edge cutting is now in -progress at repaired areas and stucco finish application at slab edge repairs was in -progress Friday, scheduled to continue next week. James E. Emory, P.E. J View of shrinkage crack routed on the Unit 7D balcony prior to epoxy filling View showing lock -off area cast back on the Unit 7D balcony where re -tensioning was completed Tuesday prior to stressing remaining cables Friday to stressing remaining cables Fridav View.of remaining north -south PT cable re -tensioning in -progress on the Unit 2D balcony KEYSTONE ENGINEERING & CONSULTING, INC. Progress Inspection Report #8 Permit #) g 1 a- o d a 3 Project Name: Atrium II Progress Report thru 4-12-19 Project Address: 3000 N Highway A3A, Ft Pierce Inspection Visits: 4-12-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack PT grease cap install and grout pocket filling, slab edge/ceiling stucco and prime/paint, drip edges and epoxy crack treatment INSPECTORS REPORT Keystone Engineering visited the site on 4-12-19 and also had several conversations with the construction team by telephone throughout the week. On the D stack balconies, all post tension cable lock -off areas have been cast back and cables have been trimmed with grease caps fitted where necessary. Post tension cable grout pockets were filled and stucco finish application over repaired areas on balcony slab edges/ceilings was finished with priming/painting now in -progress, scheduled for completion next week. Drip edges have been cut on all D stack balcony slab edge repairs and the Unit 7D shrinkage crack has been routed and filled with epoxy. Waterproofer deck coats and final top coats on balcony decks over repaired areas are scheduled for completion next week in preparation for punch out work. James E. Emory, P.E. I'IEMo • �coeNeF•.;P� No. 60965. p!a STATEO � O a ?_.;l KEYSTONE ENGINEERING & CONSULTING,, INC. Progress Inspection Report #9 Permit # r B 1 A - Oa:k3 Project Name: Atrium II Progress Report thru 4-19-19 Project Address: 3000 N Highway A1A, Ft Pierce Inspection Visits: 4-18-19 Prime Contractor: StructureCon Superintendent: Khris McConnell Activities in -progress: D stack rust spot repairs, prime/paint; deck waterproofer and top coats, final inspection, swing stage removal INSPECTORS REPORT Keystone Engineering visited the site on 4-18-1.9 and also had several conversations with the construction team by telephone throughout the week. On the D stack balconies, remaining minor rust spot repairs were completed and priming/painting has been finished over all repaired areas. Surface grinding was completed at repaired areas to minimize water ponding and waterproofer deck coating was applied over all repairs. Final top coats were also applied to balcony deck repairs on the D stack. A final inspection was completed Thursday on the D stack balconies with minor punch list work finished that afternoon. Swing stage removal was in -progress Friday and the swing stage will be rigged on the A stack balconies in order to begin marking out repairs next week. James E. Emory, P.E. NUiiaiI ��, ��C,ENB�c• ,'�i-�-i No. 60965 f'" •. � I. ' .. i . ,L �� q?.'. ,,.�F3 ��;: _ v ,a- ,F. .ic=. .... •:.vu ® �/ -ti KEYSTONE ENGINEERING fa CONSULTING, INC. April 18, 2019 St Lucie County Building Dept 2300 Virginia Ave Ft Pierce, FL 34982 Permit M 1812-0223 Project: Atrium II Condominium 3000 N Highway AIA Ft Pierce, FL 34949 Subject: Atrium II Condominium D Stack Balcony Repairs and Refurbishment Dear Building Official: i f �a- =3 RECENED DEC 0 6 2019 Permitting Department St. Lucie Countv To the best of our knowledge and belief, work has been completed satisfactorily in accordance with the project plans and specifications as indicated in the building permit package. The Scope of Work has been finished to the Owners satisfaction and all applicable warranties are issued. If any questions arise regarding this letter, please feel free to contact our office. Sincerely, James E. Emory, P.E. `���11t11111//� No. 60965 STATE OF/ 11 Phone: (321) 454-7300 • Fax: (k241459-2888 ♦ KeystoncEngineerin,�PE.com 1 Kefgf�A /M-62.z.3 kPPLICATION AND.CERTIFICATE FOR PAYMENT AIA DC DOWNER: -Atrium II Condominium PROJEOT:Concret( 3000 North Ocean Drive Tower A Fort Pierce FL 34949 G 702 (Instructions an FROM CONTRACTOR: Structure -Con VIA ARCHITECT: Keystone Engineering P.O. Box 2626 166 Center Street C' PAGEONEOF2PAGEa RECEIVED APPLICATION NO: CC7.t��,amx PERIOD TO: 6/4/1.g . 3 .. PROJECT NOS.: XownF.�r DEC 2 0 1019 pPOHITEGr CONTRACT DATE: 11/25/2018 X °DNfwcr%rmitting Department St. Lucie County CONTRACT FOR: Okeechobee FL 34973 ape Canaveral FL 32920 CONTRACTOR'S APPLICATION: FOR PAYMENT The undamigned Cwwcar cKWIRS that to the beat of the Cordmaor'seknowledge, Infer. Application Is made forpaymem, Wshpwn below, In connection with the Contract minion and bertef the Work covered by this Application for Paymenihas been completed Contmumlon Sheet, AIA Document G703, Is attached. In accordance with the Contract Documents; that an amounts have been paid by the Comraelorfor Work for which Pmvlcus Certificates for Payment ware Issued and pay- 1. ORIGINAL CONTRACT SUM ................ $45,255 .00 ments resolved from the Owner, and that current payment shown herein is now due. 2. Net Change by Change Orders ............. $ -00 3. CONTRACT SUM TO DATE (Line 1+ 2)...... 4. TOTAL COMPLETED & STORED TO DATE..... (Coumn G on G703) S. RETAINAGE: a 10 %of Completed Wort (Coumno D + E on G703) b. 10 %of Stated Material (CoUmn F.an G70) Total Raanage (Line Sa+Sb or Total In Comm 1 of G703 ..... 6. TOTAL EARNED LESS RETAINAGE (Line A lees use 5 Totap $45,255 .00 7 .00 Za;. of 9 .''w $ -Co 7. LESS PREVIOUS CERTIFICATES FOR PAYMENT r'I I , ,:3 5-/Zffl (Line 6 from pear Certfficaa) .......................... _,t:L Qge' -70 {{" S. CURRENT PAYMENT DUE ........................... 9. BALANCE TO FINISH, INCLUDING RETAINAGE (Line 3 less use 6) $23,548' .80 R SUMMARY ADDITIONS DEDUCTIONS provedhr by Owner pl�p-."dd It N. lhNh $ . TOTALS $ au,ma.,tr CONTRACTOR: By. State of: 111,149,01" latift Shannon O'DonnellPublic State of F a g My Colnmluion GG 248= Notary Pubic: `► E$plro$ call Sr2022 ARCHITECT'S CERTIFICATE FOR PAYMENT In accordance with the Contract Documents, based on on -site observations and the data comprising this application, thePrd itea certifies to the Ownerthal to the best of then Architecre knowledga, Information and belief the Work has progressed re: indicated, the quality of the Work Is In a0mclanea with the Contract Documents, and the Contractor is entitled to payment of the AMOUNT CERTIFIED,, n AMOUNT CERTIFIED /ABaah eiylanari a t a Wl fgures on ' App/ n confemlto eama I ARCHIT By: TNdG safe not negaI Is tract rnamed rain, Issuance, AIA DOCUMENT G702 -APPLICATION AND CERTIFICATE FOR PAYMENT' 1902 EDITION'AIA Copnoks •THE APIERICAN INSTITUTE OF AVENUE, N.W. WASHINGTON, D.C. 200095202 for. Initial D7-godto /rD�Iry'99 ate: u I.r' Il!' la any to the Con. are without G702-IM G703 CONTINUATION SHEET AIA DOCUMENT G702 APPLICATION AND CERTIFICATION. FOR PAYMENT, containing Contractors signed certification is attached. ITEM E DESCRIPTION OF WORK NO. 3 1 p1 Mobilization general condition; 2 12Concrete Repalrs- a a.Floor Surface b:Slab edge 4 c. Remove & reinstall rails 6 d_ Post Tension Cable Repairs 6 G. Rust spots 7 t f. Grease caps 8 g. Replace floor coating 9 EE 19 G r. GRAND TOTALS ......�._..... 3HEDULED —WORK COMPLETED VALUE _ From PreviousT Thls —Perlod— Application ! _4,500001 (D+E) ..... - ...- ,... _.._ 4,500:00 0.0[ 1,600.Od 1,629.0, 0.00 120300.0d 11,362.50 0.00 3,400;00 0.00� 0.00 20,700.001 0.00 0.00 Application No.:_6 _-----'-- __ Period to: I 4*2099, 2ob1 _—---- ..__-._.._..._. H' Materials Total (` BALANCE '`.'-_,__ presently Completed & % TO FINISH { RETAINAGE stored ( Stored to date (G + c)l (if variable rate) (not In D or E) , (D+E+F) (C - G) 4,500.00I i 0.00 I 0.00 4 { 1 -29.001 162.9C 11:362.5 937.501 1,136.2fi I 0.00� 3.400.00. n nr 1,700.06 0.00 1,700.00j 300.00 170.01 1 425,5� f 425.50 i 0.00 42.55 k 8 I .r 19,341.50 425.50.� I 19,767 00'j 23,548.80 _ 001 � 1