HomeMy WebLinkAboutEVALUATION REPORT 1CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT tl FI "° Gerti t ' Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 6Te EDITION Manufacturer: TAMKO BUILDING PRODUCTS 220 West 0 Street Joplin, MO64801EFEB CEIVED (417)624-6644 Manufacturing Plants: Joplin, MO 122918 Phillipsburg, KS Frederick, MD County, Permitting Dallas, TX Tuscaloosa, AL Quality Assurance: UL LLC (QUA9625) SCOPE Issued September 25, 2017 U2 '2 7� ST LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIA C REVIEWED BY DATE __--._ MUST BE KEPT ON JOB OR Category: Roofing I$ INSPECTION WILL BE MADE Subcategory: Asphalt Shingles .r Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 BY Properties: Physical properties, Wind Resistance, Wind Driven Rain 5t. Lucie County REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)el PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 2010A UL LLC (TST9628) 05NK28006 ASTM D 6381 2008(2013)el UL 2390 ASTM D 7158 2011 UL LLC (TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 08CAS9132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 1 OCA50498 ASTM D 3462 2010A. UL LLC (TST9628) IOCA64882 ASTM D 3161 2016 UL LLC (TST9628) I INK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 12CA24551 ASTM D 3161 2016 UL LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)el UL LLC (TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. WIN I CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass -Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. ,.Glass -Seal .. 1.AL3 ..;"0s- -I Heritage4 � .;.��Iv a (dallas, Frederick . %' a Tir.Joplin, Phillipsburg & u �IcTuscaloosa)y rear., ---- -Heritage@ Premium_ (Dallas, Frederick,, Phillipsburg & Tuscaloosa) Heritage® Premium (Frederick) Heritage® Vintage® (Phillipsburg) Heritage® Woodgate (Dallas & Frederick) Heritage®Woodgate (Frederick) 12-1/4"x 36", ASTM D •7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with ceramic granules complying ;with ASTM D 3462. Shingles shall be used in the non-HVHZ only. 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass ;reinforced, laminated architectural asphalt shingle surfaced with mineral granules 1 complying with ASTM D 3462. 13-1/4" x 39-3/8", ASTM D 3161. Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 12' x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 17-1/2' x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 12" x 36-318", ASTM D 3161, Class F fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC INSTALLATION Elite Glass -Seal® Basic Wind Speed (V�it): (Frederick, Joplin & Basic Wind Speed (V,w), Tuscaloosa) Deck (HVHZ): & Glass -Seal (Frederick, Joplin (Non- HVHZ) & Tuscaloosa) Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ) TBP15001.4 TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 1. Elite Glass -Seal & Glass -Seal 4 Nail Pattern (Non-HVHZ only) Butt Edge Figure 2. Elite Glass -Seal & Glass -Seal 6 Nail Pattern 5-118" -71Vn 5.1/8" 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 51G20-3. The manufacturer snail notny UKELK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage@ Basic Wind Speed (Vmt): (Dallas, Frederick, Joplin, Basic Wind Speed (V,,d) Phillipsburg & Tuscaloosa) Deck (HVHZ): Heritage@ Premium (Dallas, Frederick Phillipsburg & Tuscaloosa) Deck (Non-HVHZ): Heritage@ Woodgate (Dallas & Frederick) Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ) TAMKO BUILDING PRODUCTS Asphalt Shingles Max.194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturers application instructions when installing shingles at slopes greater than 21:12. Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturers published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NAIL ZONE BOND EXPOSURE 6-618" 1" h-- 12-11211-+- 12-318" - - 12-1121`--►I h--1" Figure 3. Heritage@, Heritage@ Premium, and Heritage® Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE BOND EXPOSURE 5-5/8" h-7-1/2'�-7-112"� 7�8"-►�-7-i/2"�-7-1/2"-►� N-1" Figure 4. Heritage@ & Heritage@ Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Figure 5. Heritage@ Woodgate 6 Nail Pattern TAMKO BUILDING PRODUCTS Asphalt Shingles M Common Bond Figure 6. Heritage®, Heritage@ Premium, & Heritage@ Woodgate Alternate 6 Nail Pattern Figure 7. Heritage@ (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 5of11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (V n): (Frederick) Basic Wind Speed (V.,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max.194 mph Max.150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. E/ BOND Figure 6. Heritage@ Premium (Frederick) 4 Nail Pattern (non-HVHZ only) ZONE/ NON BOND 14-1 n Figure 9. Heritage@ Premium (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage® Woodgate Basic Wind Speed (Vvit): (Frederick) Basic Wind Speed (Vwd): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater, than 21:12. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. BOND F�IT EXPOSURE 5' r, jI TLA �-- 11" �12-3ffl--+ - 11" --q �,,,1" Figure 10. Heritage® Woodgate (Frederick) . 4 Nail Pattern (non-HVHZ only) ZONE/ MON BOND T 51/2 FEWPOSURES' 1"� 9-1/2"-►�3' 93l8°-►�3W� 9-1W -� I111-1" Figure 11. Heritage® Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Heritage@ Vintage@ Basic Wind Speed (V�h): (Phillipsburg) Basic Wind Speed (Vnd): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturers application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "5 Nail Pattem" or "6 Nail Pattern' detailed below. Yposwa %%h �-IPi/T'--y'' �-1PiM'—►I Figure 12. Heritage@ Vintage® 5. Nail Pattern (non-HVHZ only) Figure 13. Heritage@ Vintage 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Hip & Ridge Basic Wind Speed (Veit): (Frederick & Joplin) Basic Wind Speed (V,�): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction prevailing wind exposure Figure 1 ��.F5a�stener n Figure 2 Figure 14. Hip & Ridge (Frederick & Joplin) TBP15001.4 FL18355-114 %xposure Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC Vintage® Hip & Ridge Basic Wind Speed (V„ u): (Phillipsburg) Basic Wind Speed (Vag): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: TAMKO BUILDING PRODUCTS Asphalt Shingles Max.194 mph Max.150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 16/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5 inch exposure in accordance with the FBC and manufacturers published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevalling wind n] exposure Figure 1 1" ` VFallt� ner 12 Figure 2 cposure "' Figure 3 Figure 15. Vintage® Hip & Ridge (Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC LIMITATIONS TAMKO BUILDING PRODUCTS Asphalt Shingles 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 It in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6r" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. ,�.. 2017.09.25 No ` 74021 11:31:41 -04'00' :9 : STATE OF %0T'•.�� i 0 R I Zachary R. Priest, P.E. Florida Registration No. 74021 -'.J5 ONA� E?�`� Organization No. AN El1669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.