Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
SMARTS ET -SQUARE TAPERED CO _"flETE•POLE s _� POLE LENGTH, FT. 28' ` POLE WEIGHT, LBS. 1530 POLE EMBEDMENT; FT. 8 HEIGHTA.G., Ff. 20 DESIGN WIND SPEED, MPH 170 MAX EPA, FT : 5.0 501C.TYPE" ` " SAND VARIES PER "L"� (4) 7/16" 270KSI a . LO-LAX@ n 18 3K EA STANDARD PIPE TENON SIZE NOMINAL DIA. OUTSIDE DIA. 2" 2 3/8" 2 1/2" 2 7/8" T' 3 1/2" w m POLE ANALYSIS (PER 2014.FBC)*. #8 GR,Ol1ND WIRE STANDARD PIPE TENON r" 5 Height Area Kz P GLM 6Mn Mu " (feet) (ft') (Ibf.) (k-ft) (k-ft) (k-it) .I 0 - 15' 11.5 0.85 1037 7.8 20.9 18.9 II15-20' 2s oso 275 a:e 10.8 1.39 � N II1° POLY PIPE EPA 5.0 0.94 356 7.1 - - II m 'm TOTAL 1668 19.7 N m ,bra - -c..>:;;., `r�,. .y r...:.. EMBEDMENT ANALYSIS .":5 LL._. (PER 2014 FBC.SECT:'1819) :' _ P=SUM(P)*.6=1001 lb ' '0 3"x5" HANDHOLE SP=150.(SAND) W/ALUMINUM COVER F. 4 E S1=2*SP*D/3=800 N b=0.96' (POLE DIAG. WIDTH @ D/3) F A=2.34*P/Si*b=3.0 0 w ., r F vE % r S' ' it • rh=GLM/SUM(P). 11,82E [ J '• - - ,I ` �" REQ'D EMBEDMENT.d 5A(1+[9+(4.36h/A)]^1/2). 7.98' qw OR 1" REQ'D EMBEDMENT.K. d <= D therefore O_ w I ELBOW �Q .162" THICK - O I I m SPIRAL (TYP-) • Exposure C, Risk Category II, Gust Factor=1.14 (TYP.) POLE O.K.? YES EMBEDMENT O.K.? YES in N CERTIFICATION: ii o rrri , p �I` "'#8'GROUND i : iI2..:1(��i'1'i.C�+l'`'•i�"ld°�°''<�=tE e S z WIRE. €'\1 ��;• NQ. w No. *.Z= 6330 c STAT OF II' nO'R10 . .r�9.5"r.9.,5• i sl�/,s/�'SAI-E�G\+,y'..' �i).. il•,";? POLE ELEVATION' REINFORCEMENT Chris Arlandson, P� N.T.S.. N.T.S. FL Lic: No. 63302 PROJECT NAME: /* a�T WORLD/SUNSHINE KITCHEN S P E A L T 6 C 1, A T I. E s SmartLine Design PROJECT NO.: 72777 PRE -CAST SPECIALTIES, INC. Always On. 13BO N.E. 48th St. Pompano Beach, FL. 33064 POLE TYPE: 28 FT. TYPE I Ph:1-800.749.4041 Fax: 954-781-1194 Wiwi h xkS�ij:..'{"' J .... f r ° :Y � � J C t i 1'�'^ srsf N : i� � 5"(£� £� A �[Fr N•tiw (1; i�. 3�l 9 tyrr Ays L` L `J II 9 x l !s. i I nt _SI 1 of ITT -�- a Ht 1 a J v ! - t la Xr R 4)_ jo- r}.Tn Jrl. ufhd.. •� iaµ4 +��'S �'J .. nyi ` 'f ff2 r41W .Ir4 , RS.t 4 Y J ,.'S 4 i' s' �• , .htk'• .h. ..�•:r 1 att •. .� .. � a. v .. s .. vim_ " i 4 `' ¢. �«h•ti�y° �10. {>, tt 1 3 if ties S �( � ie i r '�� vl �?i.€ T {.. A J •» I.. t �• 4V Itook,_j.v,i s u( of Ty of lrG n' ;I y'f}t}� y h Y_S,fiFZfV.•4':i'iM4ft'rt..F.�.]10-`�i .�1d6.5'.f4]...��r')'rif v(7rtvG1G(�iatNltS:t'1 F3 41 {.vnj �:'s th �.Ya`{. .Yi.{3'i iiS�.. ✓ s_ . . 5. 1;:. Ra .._... a _rF'S x SMARTS. ET=SOUA RE TAPERED CO RE'TE POLE , POLE LENGTH, FT. 28 POLE WEIGHT, LBS. 1530 POLE -EMBEDMENT, FT. 8 HEIGHT A.G., FT. 20 DESIGN WIND SPEED, MPH 170 MAX.: EPA, lFT•:.- SOIL TYPE . SAND ,Y VARIES PER "L";I' w a, N � w c� t z#8-GROUND WIRE 5" STANDARD PIPE TENON tO 1" POLY PIPE II { 0 3"x5" HANDHOLE W/ALUMINUM COVER z J M.162" THICK - SPIRAL REINF. �t. (4) 7/16" 270KSI LO-LAX @ STANDARD PIPE TENON SIZE NOMINAL DIA. OUTSIDE DIA. 2" 2 3/8" 2 1/2" 27/8" 3" 3 1/2" POLE ANALYST$ (PER 201' FBC)' Height (feet) Area (ft') Kz P (Ibf.) GLM (k4t) OMn (k-ft) Mu (k-ft) 0 - 15' 11.5 0.85 1037 7.8 20.9 18.9 N n � 15 - 20' 2.9 0.90 275 4.8 10.8 1.39 EPA 15.0 10.94135617.1 1 - TOTAL 1 1668 19.7 1. '( "EMBEDMENT ANALYSIS .:.(PER-2014 FBC SECT.:181'9)«.::' - P=SUM(P)'.6=1001 lb v SP=150 (SAND) a S1=2'SP'D/3=800 ' b=0.96' (POLE DIAG. WIDTH @ D/3) A=2.34'P/S1'b 3.0 Li'l;=h=GLM%SUM(P) 11i82'•,Y � ..'=it+' .r.• ..�^c==..'� _... ..:.. REO'D EMBEDMENT d_.5Al1+f1+l4.36h/A)lA1/2} _ 7.98' '' • � •�->- �. #8 GROUND z WIRE w W 62 LU � o REO'D EMBEDMENT d <= D'therefore O.K. ' Exposure C, Risk Category II, Gust Factor=1.14 T POLE O.K.? YES EMBEDMENT O.K.? YES CERTIFICATION: rrrr `� �5 A v "C No. e STAT OF � *; 90, Op�ORIO,! 9. ; POLE ELEVATION REINFORCEMENT 'Chris Arlandson; P:El's, . N.T.S. y;..:;,..... .. N.T.S. .... - FL Lic: N6 63302 PROJECT NAME: A WORLD/SUNSHINE KITCHEN PRE�r-eST s P E 0 1 A L T E 6 Ti 17 '/�`j SmarfLine Design PROJECT NO.: 72777 PRE -CAST SPECIALTIES, INC. �`/ ALways On. 7380 N.E. 48th St. Pompano Beach, FL. 33064 POLE TYPE: 28 FT. TYPE I Ph: 1-800.749-4041 Fax: 954-781-1194 f SMARTS -ET-SQUARE TAPERED CO__ RFrE POLE POLE LENGTH, FT. 28 POLE WEIGHT, LBS. 1530 POLE EMBEDMENT, Fr. 8 HEIGHT A:G.;FT- 2 U. DESIGN WIND SPEED, MPH '170 MAX: EPA, Fr4 5.0 SOIL TYPE SAND AP VARIES PER "L"�' LU 27 (4)7115, OKSI, 18 3K EA STANDARD PIPE TENON SIZE NOMINAL DIA. OUTSIDE DIA. 2" .2 3/8" POLE ANALYSIS (PER 2014 FBC)' #8 GROUND WIRE STANDARD PIPE TENON 5- Height Area Kz P GLM 0Mn Mu Fl (feet) (w) (Ibf.) (k-ft) (k4t) (k-ft) R 0 - 15' 11.5 0.85, .11,037, 78� 30.9 18.9 RECEIVEQ- 9 tA9 a4 09 A IS - 20': 2 9: 4 0 FEB 16 2018 ST. Lucie County, Permitting 1- POLY PIPE m EPA 5.0 0.94 356 TOTAL 1668 1-19.7-1 • m EMBEDMENT ANALYSIS (PER 2014 FBC SECT. 1819) P=SUM(P)*.6=1001 lb 3"X5- HANDHOLE Wl ALUM�NUM COVER SP=150 (SAND) L) Si =2*SP*D/3=800 • 'law A=2.34* P/Sl'b=3.0 z h=GLM/SUM(P)=11.82' REQ'D EMBEDMENT d=.5Aj1+[1+(4.36h/A)]A1/2j = 7.98' R I ELBOW .162" THICK REO'D EMBEDMENT d <= D therefore O.K. > REINF. SPIRAL• 0 (TyP-) Exposure C, Risk Category 11, Gust Factor=1.14 POLE O.K.? YES EMBEDMENT O.K.? YES L PLA { CERTIFICATION 6 #6 GROUND BLDG: R Li z WIRE DATE' Lu E b=8.62" ELEC 9 NO. 330 D FLU 9 @ STATE F EOor .0 POLE ELEVATION REINFORCEMENT Chri rian son-0,-i- N.T.S. N.T.S. FL Lie. No. 63302 PROJECT NAME: rr-% ON C=T � ll. WORLD/SUNSHINE KITCHEN I A L T 1 E 8 PROJECT NO.: 727,77.S INC, I -�T. TYPE I 'i 380 N.E. 748th St. Pcinpano Beach' PEI 33064 POLE TYPE: 28 Ph: 1-800-749-4041 Fax: 954-781-1194 } LFVV 151--A jfz vI 72' 2 (sr.i a;ie �ysr'yisu a i - d. 6 ry. 14 f(, r.�, t {'l) }tl+t1S.•1�rFrY fin=♦A.,ayR � �. �.. r l4 't� t ��I :: k.11 � t !r ♦.��it I rI i v,t,S,S f� R'Y�dR .... R (' t, v, A`' s •� i' { _ •__ 1 tJ (� r l i t 7�`) IS N o- - . , f s af' ti Cl � klt -s R f V 'A44 yr, l k rYfil RlY�-'�'a-�}'41r15�`F'if t la.. S tytf ult qW I' SE5c0 Lighting 737 STatgIm Road, Ft. la0derdale, FL 33326 a cr)ption: I project: ECF-S-32L-IA-NW-G2-AR-4-d' `(-BZ-PTF2 TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G Type: I S L1 Tcj Ws4)a2a M franuf 47441n Notes: PH i Li PS G GARDCO Ordering guide Project: Location: Cat.No I,5 C 93 oty: Notes: The Philips Gardco EcoForm Gen-2 combines economy with performance ' - in an LED area luminaire. Capable of delivering up to 26,400 lumens or more in a compact, low profile LED luminaire, EcoForm offers a new level of customer value. EcoForm features an innovative retrofit arm kit, simplifying site conversions to LED by eliminating the need to drill additional holes in most existing poles. Integral control systems available for further energy savings. example:ECF-S-64L-900-NW-G2-AR-5-120-HIS-MGY Number Drove LAOC.tor- - Cmhols sectriW LmnivLe Dea6e of [.rowers Uanaratlm rAemtlng OlspbdAn Voltage Farm ECF-S EC's 33L AO Ml.m WW-G] AR Type3 130 12JV 1M DO 0-lOVOimmin80dmrs TR Terminsl Mno1 RPA TeaWmd EcpFom J21FDs Wa'dmte AFm.Wea 30g OCC Dual GrMteoname Fowcooll, II isFunwig 01adc 9leandbe 2naduMs 'NI0 3000K, ]OCRI (sfandartll° 2-90 Rotated 240 240V Pbotcelxtrlr/ReugGdesym-= AilaPter(flts y/N White Smell Mmup, Gerecaw2 MN90' 2-IIO Rda[etl M 34] NUV R single ama.2n.3mAL]e P2 Dolble W3'-J9' GoDOW)o R2 0r.rp OGY OarkGNy to NW-G2 pV.wo (TwM1aNRe¢pMtlel pC0 PhoNcdlb.l Bu[bnee IOSOmA Newal NTiM rigM2]0' 400 400V TIFIDS NIS MGYMedum Gray karmrII UNV 120-2IIV iwUtLOGRernOm<1e5pin ROB.2<O,aBOVAp' L2A COOOK.]OCFb MwdaN seotrse Type3 50V60 MJRIV Twbtl ReceptadeePin Pula MamtFusi'q Intel gnggomerspetlfied 1200m GenereIon 2 nr<e+•-urRU 3Type3' HV11 341.400Y r Twstl.ds Receptxlew/Dhomcelis Huse Rural. Specify 4 900 FM Single ample), 34NAQs Cliff SF yyD RpGlgd ISW60H0 Oyr1a01mmer:ANomaticProfi@Oimrrnng 9tle5hielo` op0orlal C95o Safery50%ummin&lhours' dB8 IFDs 901 CpoltMlre go utter IeN90' fP3 ample color.'RAL (3motlules) lA SOUON, Mourns }��f2 50 m d 1O50mA Geneazl.2 (o2/e r18MmJ• CF30 EmnoY%DmmnR9Rou' '�aOn'�Pull FP3 ee Gotoroolo, 1.N O.D.ero) DA0M (208.240.43MQ1 Nectsupply ROmA IRS Wallmanl TY%4 IMared M.tlm ReSparsse SY#a+ns SurgeProhcE.n coloacip (vremared Of Sao 4r a 4-90 R.M[etl IMR131nle8'alwith7Ierlss SM SfandardlORA wlhsslas, faYory r14Ii0s Mn"A Ieft90' IMRD INe6mIwNRT Mrt^ SPS Increased 20Wl mmMl (4 modules) fA mndlit 10I usuenlry 4-210 Refused Pole Mounted loharetl M.Oanseslanse permitted dirt IIO` if,stamwith Dynalumma as"MR0 wNSafery50%OimmnBu RAM TI Retr.Fdoren MO-IMRO wNMedan50160snMngu SType6 mowtict' CE50-IMRD wNCmIm1Y50%DmminBo SW iYpeSW DA504MR0 wiNAONight5010im'Nngre AFP Net.1c,duem@tewrse) SIN IntegralmodAe^" Auto Pent Row M-90 SW-IMRO Polemountedmowm Awrisrent R.W, sipOnYppb.n Rwaredkft90' WL¢rnsiyLan ` 4NO LL(3 Integralmodrlewth F2Mnsa AN. FraNRm/. LLD IntegralrroulewNYJlens,e R.ta4erightZA1' LLC4 N[egNlmod'MwM x4lerN!e I. AvailableoNy.no0.208,240,Wd2n(orUN113 6, DCCand LLCII3/4nofanllUble Mlhanyothermntrols It Umited t.amatlmumof46degreesaiMngabwehodmnfal 2.. SpetltyV.ltage 2 TRMtavallablewllhliCC 12. SVV.;d1 W1.tavNablewllh any. the ri pptlpn5 3. Not availabi. An 141.1450 voltage & ECF-IMRleput... d with out -boarded sensor hpu9ngwhen with the ertepfine of IMRI3. IMR12 and SW-IMRD motion 4. HISnoravaltable with Tvpe 5 or 5W.piles voltage is NW (U]-480V) resppneeoptions 5 DO is repuhed for ILCR and pole mmunt mpN.n sensor. A Mounts toaa- raw pole wllh adapter Included for R Available only on 120Vand 223V Dlmming Wads are supplied through back of Overrule. swarmle5 Merl be preferred sa arraty(See aaerrodat I ID. NotavailablewlM SFand Wi RPM pr.vldedwlh bNQfintib standard ECF-6_Gen2 06/12 p.,elof9 escdption: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting 737 Shotgun Road, Ft. Liablee, FL33326 Project•. TCERDA SUNSHINE KITCHEN FOOD BUSINESS #'16-3549G atislao'e"3ga rm:ryHypas]n: (Notes: - ECF-S EcoForm small Site & Area EcoForm Accessories (ordered separately, field installed) - Controls Adcpsrmies Pale Mount MOHan Sensor MS-A-I20V4 120VInput MS-A-Z - 2TNlnput Wireless systems Remote mount module LLCR2-IF)^ #21ens 1LCR3-(F)1 #31ens LLCR4-(F)e #Ilona Central Remote Mallon Response (usescdnnecb urosayeisemainpanel M52-A-FUR-3 MS2-A-FVR-7 ILEDoptianrepuirad I2 Nptavallabswilh rr15 m 5W optics Sktlding A«asmdes° House Sudeshidd Standard orientation HIS-1i Internal House Side Shield for 32 LEDs(2 modules) HI5-IB-H2 Interest House Side Shield for 48 LEDs (3 modules) HIS 11- Internal House Side Shield for 64 LEDs(4 moputes) A t 90 or DO orientation: XIS-12-Vu Internet House Side Shield for 32 LEDs(2 modules) HIS-18i Internal House Side Shield for 48 LEDs IS modules) HIS-64-Va Internal House Side Shield far 64 LEDs In modules) Lumina'ueAopsodes Type: SL1 ECF-13i Bird deterrent PTF2-(F) Pale tapfitmfits218-212'ODx4'depth tenon with1. 2fi or 41Uminaiw,at90' PrF3-(F) Pole top fitter fits 3-31/2'00 x 6-depth tenon with 1, 2.3 or 4luminaires at so - Pill F) Pale top fitter fits 3 l/2-4-ODx6-depth tenon with 1.2. 3 or 4luminalres at 9o- ECF-SF-G2-(F) Silo Fitter Mount (fits to 23/8-oD. tenon) ECF-RAM-G2-(F) Retrofit Arm mount kit ECF-WS-G2-(F) Wall mount with surface conduit rear . entry permitted (F)• Specify finish Predicted Lumen Depreciation Data Predicted performance derived from LED manufacturer's data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may very due to field application conditions L)o IS Ne predicted time when LED performance depreciates t0 70%of Initial lumen output calculated per IESNA TM21-11. Published L70 hours limited to 6 Drees actual LED test hours 25'C j up to 1200 mA 1 >100,000 hours 1 >60,000 hours 1 >88% LED Wattage and Lumen Values Ordering Code Total LEDs LED Current (mA) Cola, Temp? Average System Walt' Type Type 1`Tpe4 Lumen outputrl BUG Rating Eficrej (LPM lumen Outputs° BUG Rating EAieacy (LPW) Wmen output" BUG Rating Elficacv (LP'N) E0E-S-32L-530-NW-G2-x 32 530 4000 56 6,864 ' 62 UO-G2 '=ID 6715` :'BI-U0-G2 121 1025 61-U0-G2 *6 ECF-S-32L-200-glya x 32 700 4000 n 8,853 82-UO-GZ 121 8.661 B2-UO-G2 119 9062 61-UO-G2 124 ECFS-32L-U-NW-G2-z U 1050 ` 4000 _ 106' -8464 B3 UoG2 118 UJ94 B2-U0-G2 115 12357 B2 UP-G3 ECFS-32L-L2 -11111 x 32, 1200 400D R2 13,826 93-UO-G3 ITd 13,526 62-U0-G3 Ill 14,151 B2-UG-G3 116 FCFS-48L 900 NW-G3 x - 48 , 900 46M 135 - •16,409 83 UO-G3 12I 1602 '.32-UO G3 119' 16295 B2 UO-G3 124 _ ECF-S-481-1A-Mil 40 1050 4000 159 18.581 B3-UG-G3 ID 18,98 B3-U0-0 115 19.018 B2-UG-G4 120 ECF 5 48L 1.2A-NW-G2 x 48 1210 , 4000 183 ., 2DS21 B3 UO GB 1n 20180 IB3-UD-G4 110 21,112 83-U0-G4 116 ' ECF-S=64L-900-lli 64 900 4000 I]0 21.717 B3-UO-G3 n2 21.246 B3-00-G4 119 22.228 33-UO-G4 125 E6-S 64L 1A-NW-G3-x 64 '„ 1050 '4000 1- 206 Qa,467, 63 u0 G3 -119 23938 03EU0-G4 .116 1 ideal B8-UO-GG 122.: Ordering Code Total LED Current (cos) Color Temp? Avenge SYslem Wafts' bi5 Type SW Type AFR Wmen 0dpur2 BUG I Rating Efficacy (LPW) Lumen _Ouuad12 I BUG Rating Efflo, (li Wmen Outputs' BUG Rating Eficay (li ECF-S-321L-530-11W-G2z = _LEDs 32." 53D ' 4000 - 56 ]pia B3-U)-G2 133 7J75 B3-UO-G2 U9 7.111 N2 Ui 'Us ECF-S-321.400-11W-62-x - 32 70) 4000 7! 9.563 B3-U0-G2 131 9.255 Ba-UO-G2 127 9,172 N-UO-GI 126 Ea,-S-32VIA-NW-Gbx .. 32'. 1050 •400a 1111- 13.462 B4-U0-62 IN' 3,030 B4-UO-G2 i23 12912 B3410-G2 i. IN ECG-S-32LAM-11W-G2-x 32 1200 4000 IN 14,933 94-UO-G2 in 14,453 84-UO-GZ 119 14,322 B3-00-G2 118 ECFS daL-900-NW-Q-i 48 90D. ''4000 Ds 1],]23. B4 U0 G2 131 17156 05-Ui - V 16,999 B3-UO-G2 Rfi ECF5-48L-tA-NW-G2a 48 1050 4000 159 20,069 BS-UG-G3 726 19.424 65-UO-G3 122 19.N8 B3-UO-G2 - RI ECFS-d8L-13A-NW-G3-i 48 Doo 4000 i&i '12,2I9 BS UO G3 @ 21563-Q-W 63 -:118 $360 B3-U0-Q' .0] ECF-5-64L-900-NW-GT 60 900 4000 I18 23,d56 es-UO-G3 132 22.IO2 Bs-UO-G3 12B Rp9] R3-W-G2 127 ECFS 64L M-NW-Qv ° 64 1050 • `4000 206 26,42T Bs UO G3 128 25577 85-U0 G4 124 25,346 K U0-G2 U3 1. Wattage and lumen output mwvaiy due to LED manufacturer forward volt spKification and ambient temperature Wattage shown is averi 120V thmugh 27N input Measured wattage may vary due to venetian in input voltage. ECF-5_Gen2 06/17 page2of9 2. Lumenv iue basedonphotometricteshperformedincomprunmwiMl SMLM-09. 3. Warm while color temperature MIT dealt in deemased lumen output Contact outdocrgghtingapplimtions philipscom fordetailsaradditlonal information. SESCO Lighting �scriptfo"' ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 Type: ^` 7376batgun Rasa, Ft.. teuacate, Fu3325 Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS #'16-3549G +tn A`05A.n4M r (rq'4em. Notes: ISL1 ECF-S EcoForm small Site & Area Dimensions Standard Arm (AR) Weight 22 Lbs(99 Kg) EPA:0.21fN(019m') 50' 02,71 275'(697am) Retrofit Arm (RAM) Weight 24 Lbs(109 Kg) EPA024ff'(022m9 Nis Outboard ]MR-HVU sensor r---.-----.. --- - -- - - ECF-9Gen2 06/17 page3of9 Wa(I (WS) Weight 271-bs.(12. 21(g) EPA027f`(025m') 65' 065 mJ 2g3"Q45cm) Slip fitter (SF) Weight 27 Lbs(12.2 Kg) EPA:033hi(031mii 6P 023tm)(96 ) Standard Arm (AR) drill pattern oar a axml 1 asp: IV P 1 3 f5uy I Cbnl Retrofit Arm (RAM) drill pattern �.11r : scrlptlon: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 SE5CO Lighting Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G 737 Shotgun Acrid, Ft. Lauderdale, R 33326 1qN` rmi )474,eDN raail4r4M47N Notes: ECF-S EcoForm small Site & Area Luminaire options Do: 0-10V dimming driver with leads supplied through back of luminalre (for secondary dimming controls by others). TLRDS: Twist Lock Receptacle with 5 pins enabling dimming, can be used with a twistlock photoelectric cell or a shorting cap. Can also be used with Philips or third party control system. Receptacle located on top of luminalre housing TLRD7: Twist Lock Receptacle with 7 pins enabling dimming and additional functionality (by others), can be used with twistlock photoelectric cell or a shorting cap. Can also be used with Philips or third party control system. Receptacle located on top of luminalre housing. TLRDPC Receptacle with twistlock photoelectric cell (must specify voltage). Receptacle located on top of luminalre housing. Dynadimmer Automatic Profile Dimming: Automatic dimming profiles (CS50/CM50/ CE50) offer safety, median, or economy settings, for shorter or longer duration. Dimming profiles provide flexibility towards energy savings goals while optimizing light levels during specific dark hours.50%dimming Is standard. DA50 offers 50% Instantaneous dimming all night (during afl dark hours). 75% and 25%dimming is also available if different light levels are required (contact Technical Support for details). _.- . . Economy 50% r9hours 9PM-6AM' Median 50% 1 8hours IOPM-6AM Safety 50% 1 7hours IIPM-6AM Reactive50 50% 1 dynamic I allnight ' IMRI3, HARD: Infrared! Motion Response Integral. IMRI module Is mounted Integral on driver door and is available with two different sensor lens types to accommodate various mounting heights and occupancy detection ranges (see charts for approximate detection patterns on page 7). Motion response used in combination of Dynadimmer and SlteWise are not programmable and used to override controllers schedule when motion Is detected. When used not combined with any controller. IMRI is set/operates in the following fashion: The motion sensor is set to a constant 50%. When motion is detected by the PIR sensor, the luminalre returns to full power/light output Dimming on low is factory set to 50% with 5 minute default in 'full power° prior to dimming back to low. When no motion is detected for 5 minutes, the motion response system reduces the wattage by 50%, to 50% of the normal constantwattage reducing the light level IMRI can also be specified with automatic profile dimming for the added benefit of a combined ECF-5_Gen2 06/17 page4of9 Type: SL1 dimming profile with sensor detection, where OCC: Dual Circuit Control permits separate the PIR sensor will override the dimming profile switching of a specific number of LED when occupancy is detected. Passive infrared modules. Available as an option with (PIR) motion sensor. through 4 modules. IMRO: Infrared Motion Response Outboard pole mounted sensor. must be specified with an available automatic profile dimming option. Combines the benefits of both automatic profile dimming and motion response using Me Philips DynaDimmer technology. PIR sensor features a pole mounted Wattstopper EW-200-120-W or the EW-200-277-W. One motion sensor per pole Is required (order MS-A-120 or MS-A-277 separately). Available In 120 or 277V only, IMRO sensors require single voltage 120V or 277VInput (see chart for approximate detection patterns} If motion is detected during the time Nat the Luminaire is operating at profile dimming mode specified, the lummaire returns to 100% power and light output The luminalre remains on high until no motion Is detected for the duration period. after which the luminalre returns back to automatic profile dimming. Duration period is factory set at 15 minutes, and is field adjustable from 5 minutes up to 15 minutes. The area motion detector provides coverage equal to up to 6 times the sensor heightabove ground, 270° from the front -center of the sensor. SW: SlteWise option is a fully Integrated controller that connects to Philips SiteMse system in order to offer a complete area lighting management system. The communication signal is based on Philips patented central dimming technology. SiteWlse delivers it deliver optimal energy savings using your site's existing cabling. No additional wiring required. Installation and commissioning are simple. An Intuitive, mobile app makes it easy for authorized users to set schedules to meet site specific lighting needs, local regulations, and energy codes. Wireless systems: Controller radio/sensor module attached to Luminaire arm and Includes radio, photocell and motion sensor. Available with 92 tens (LLC2) for 8'to 15' mounting height' or #3 tens (LLC3) for 15-25' mounting heights or #4 lens (LLC4) for 25- 40' mounting heights. Also available with remote pod accessory where pod is mounted separate from luminalre to pole or wall (see accessories and wireless system information page 5-7). Pate Detains: IMRO requires that the pole F7: Fusing Single (for 120.277 or 347VAQ 'Induce an additional hand hole 15 feet above the pole base, normally oriented ISO- to 2: Fusing Double (for 208, 240 or 480VA FQ the standard hand hole. For Philips Gardco FP1: Fusing Pole Single pates, order the pole with the Motion Sensor (pole mounted near handhole, 270-Front Coverage for 120, 277 or 347VAQ Distancesare FP2: Fusing Pole Double / approximate. (pole mounted new handhole, 90° H= height above ground for 208, 240 or 480VAQ. Height R� FP3: Fusing Pole Canadian Double Pull f (pole mounted near handhole, 1H 3H 6H far 208, 240 or 480VAQ Mounting (MSM) option which Includes the hand hole and a special hand hole cover plate for the sensor with a 1/2' NPT receptacle centered on the hand hole cover plate into which the motion sensor mounts. Once the motion sensor Is connected to the hand hole cover plate, then wiring connections are completed In the pole. The plate (complete with motion sensor attached and wired) is then mounted to the hand hole. If poles are supplied by others, the customer is responsible for providing suitable mounting accommodations for the motion sensor in the pole (see Gardco Poles specification sheets for more Information). SPI: Surge Protection, IOkV/SkA, 120-277V or 347-480V SP2: Surge Protection, 20kV/10kA, 120-277V or 347-480V HIS: Internet House Side Shield. Injection molded in black finish. Ships installed with 1 per 16 LED module. Also available shipped separately as an accessory for 2-4 LED modules. SESCO Lighting eaprlp. y Proj 737 Porn. Ries, ft. [nusedale. fi M26 ect: T&")aa:ssra rm:lxnn> 4n ( Notes: ECF-S-32L-lA-NW-G2-AR-4-Ul V-BZ-PTF2 Type: TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16.3649G S L 1 ECF-S EcoForm small Site & Area Wireless system — tuminaire configuration information LLC2/LLC3/LLC4 Luminaire Mounted Controller LLCR2/LLCR3/LLCR4 Pole Mounted Controller Controller pod attached to Iuminaire and Includes radio. photocell and motion sensor with #2, #3 or #4lens for 8-40' mounting heights. Recommended Sensor by Pole Height 40' 35' 30' 25' 20' is, is I I I ILLC2I LLC4- Wireless system sensor ECF-5_Gen2 06/17 page6of9 In this configuration, the wireless controller will be mounted to the pole at a fifteen foot mounting height The number of luminaires on each pole, as well as the specific wattage chosen, will determine how many controllers will be required. When using the wireless remote accessory option (LLCR-F) In a pole mount application, specify pole option (CL=Coupling Internal Thread. 3/4' size). Confirm required orientation of Iuminaire and wireless controller. Indicate height above pole base and orientation to hand hote. Recommended min pole height is 18ft. with option (CL)15ft above pole base. Other heights are possi bte when choosing the appropriate sensor lens type. See pote speclficatlon sheets for more Information. 1. Photocell - Ambient light photocell pn every vnreles radio that averages the light levels of up to 5 controllers for an accurate readl no and optimal light harvesting activity. - Reports ambient light readings to 1500 Fc. 2. Motion Response - Detects motion through passive Infrared sensing technology with three different lens configurations. - Motion sensor coverage can be adjusted from a narrow to a wide detection range, which helps reduce false triggers to further increase energy savings. - Sensing profiles can be updated to adapt to activity levels in the environment, such as occupancy level, wind, and mounting height. Remote Mount Wireless Controller . Used to extend the communication on site, to extend motion response and add other luminaires that are not pole mounted. Consult factory for more information. 3. Wireless Radio -1.8 Watts max (no load draw) - Operating voltage 120-277 VAC RMS - Communicates using the ZigBee protocol - Carries out dimming commands from Gateway - Reports ambient light readings to 1500 Ft-Cd - Transmission Systems Operating within the band 2400-2483.5Mhz - RoHS Compliant SESCO Lighting ..0sctiptlont ECF-S-32L-IA-NW-G2-AR-4-UNV-BZ-PTF2 7376hot9un Re25, FL lauftdale, R33326 Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS 9 16-3549G rtt'c� T&j;34n33ro ra 14n2424nm: Notes: ECF-S EcoForm small Site & Area Infrared Motion Response — Coverage Patterns LLC2/LLCR2 30' Luminaire or remote mount controller with #2 fens 20 10' 0' 10• 0 2 8' xb' n- 7 3' 0' T T IT24' IMR13/LLC3/LLCR3 Lumina!,. or Remote mount controller with #3 tens o' 1. 15' 20• 20' IT IS IT 9' 6' 3' 0 3' 6• 9' R' 15' IT 20' LLC4/LLCR4 Luminaire or Remote mount controller with #4 tens Immo ,. Mini ., � � 15�'II Il1fI\ � � ►lif�Il 30' 20 I2' 6' 0 6' 12' 20' 30' MR17 Integral motion response - with #7 fens 71 tt J 20• to 0' 19 20' 20 10' P In Z. I W' W 27 20 IT 6.3. 03'e 12' 20. 2730' 0________/_/_-----__________________ f% 50' 40' 30' 27 to 0 to 20' 30 40' 5a ECF-5_Gen2 06/17 page 6 of 9 Type: SU er .)ascription: ECF-S-32L-IA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G )l) Shotgun V`eia FL. (iSiIu'ale,1" SIil6 tta. )c�a?nasue na; (nalnagrn Notes: ECF-S EcoForm small Site & Area SiteWise system Type: SL1 SiteWise is a complete area lighting management system including a luminalre Integrated controller, dimming signal transmitter cabinet, and locally accessible user Interface. Installation and commissioning are simple. The cabinet communicates with the Philips Luminaires using patented central dimming technology. The control signal is embedded on the existing electrical line - no new cabling is required. An intuitive, locally accessible interface makes it easy for authorized users to set schedules in order to meet site specific lighting needs, local regulations, and energy codes. SiteWise system diagram rMMorris .. a u I r Gateway; Authorized user ® r • �' i Dtmping4 sigrtat Verivni[ter r aiid Rarrzf- - SiteWise system interface SiteWise hasan intuitive user interface that makes it easy to plan, edit, and implement lighting schedules for your site. Authorized users can access the interface via a local app. To ensure that only authorized users can access your lighting. SiteWise offers two user types, each with different permissions. An advanced user, or administrator, can set and edit schedules using the ten pre-set scenes, assign those schedules to calendar days, and check system status. For everyday use, a basic user can manually override a schedule that is currently running but cannot create or edit schedules. SiteWise system specifications The SiteWise system includes both luminaires and controls. The controls used for SiteWise are circuit load dependent. Required for a complete Installation are the following Philips SiteWise components: user interface, control kit, dimming signal transmitter cabinet, and dimming signal receiver located in the Philips luminalre (SW option). Optional lummaire-Integrated or external motion sensors may also be specified as required. Within the electrical closet the control kit and dimming signal transmitter cabinet are Installed into the electrical system between the existing breaker panel and the site luminaires. New LED luminaires containing the dimming signal receiver are Installed on the site. Once completed, use of the interface allows for scheduling and override capabilities. Wireless access point and tablet should be supplied by others. Complete Information on the control system can be found on the SiteWise website at philips.com/sitewise ECF-S_Gen2 06/17 page7of9 Liescrl ❑on: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 Type: v ?, SESCO Lighting I l Pro Sect, TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3541 )3r hotgun Aced, % LZrals dMe, FL M26 `»_TG (9•,4Jerss395 rm:(alp9ISL2 e4.9m. Notes: PH 1 L0 PS CM GARDCO Ordering guide ProleCl: Location: Cat.No: Type: Qtx Notes: The Philips Gardco EcoForm Gen-2 combines economy with performance in an LED area luminaire. Capable of delivering up to 26,400 lumens or more in a compact, Low profile LED luminaire, EcoForm offers a new level of customer value. EcoForm features an innovative retrofit arm kit, simplifying site conversions to LED by eliminating the need to drill additional holes in most existing poles, Integral control systems available for further energy savings. example: ECF-S-64L-900-NW-G2-AR-5-120-HIS-MGY Number Drive IFa Caw- • • • •. Grads Electrical Continuednish Prefia ofl60a Current Generation Mwmdng I1h63uthon Voltage ECF-S ECFS ES— SIO WW-Q AR Type2 120 120V 00 0ANDlmming Orwers TB TerkrW Bldde xbbed 82IEOs 90m WarmWNle Arm Monl 208 20W DEC OvaldcW[Corf�ol° 2TVpe2 Black 9teandama. (2mddulea me 3000K.1. (sMntlmdfe 2.90 Rotated 240 2401 Fuafi9 N µbilell 200mA Decension2 Rafael 342 34N - pM1ONeIxW (IMALodrRemptacle) Fl 9ngle (120.Zr2.34N!'Qe F2 DoubleNexpediv BmnqW-Q GY DaMal - aberwv"2-2M P® PM1otomnbolBmmn" rite era mhtZM' 4R0 480V UNV 120-Mnvir TLR05 Twhtlpd ReapddeSPin (208.240.4BU'Aq' . evx.m ay 1IA 4000Y,fiCRJ waMM srynaeyl We Tema 50fi0Hz TLRW TWIk Lack Raceplader PN Imerad Cusbme",fe0fied 1M0mu, Geneatlon2 3rype3 XW 34ri90V RRPL Twist LOIX RempMdew/Photaella Pole MowtRsrlg Hose RAL 40L � 900 CW-G2 SF 0.90 Robinson! (50/60Ha) Dyiu0kmner.Au[omanc Profile Dimming FP1 SNgIe r 9de5hlelda optioned op8oial 481FDs 90CMA Cool9fond SupRtter Ieft90' Double(aoM Fp2 Double (ehaRAL7al C550 Salery50%gmmin6.rM1ours' unidules)U 5000Kr0U0 Mwmte }2M AdIXea UN50 MedianSD%gmminRBMms' (M8.240.d80VAC1a (ec RALM34) 1o50m4 Generation2 (fi[SN3'/e' rgld7Xr CE50 Ecdnomy509fDimmb891nois' rya CanadianOwde Wll CC Oubmcolos LZA OD.lenon) DASD Al Night50%gmmin8' Q08.240,480VAQl (Mustarpply 1M0mA 4V5 Tropescobrchip Nhared Motlan Raspwee5ystan Solehente[Oon M remdred 64L 900 4i aPon 4-90 Related SA SbMaN10kA 64LL05 9Wm4 Nwalmoro',re,ar wiNonfam merit Ieft90' Von lote8ralviNA3lere- IMRR InbBralwith A)lerrs° SPB lnaeasetl20NA aware) awfacare) (4modWes) u 1050m4 rearenby d 0.1M Rotaright Pale Moukedlkmredress RezpbrOe ceollted dgM2]0' syzkmswiNDyx0lmma MOAMIAO WINSafdy MOlmmi RAM Tripes fiedeffitarm CM504MAO w11M1 Me6an50%gmMnB�s ST3pes wont Ml° CE50-MIRO WIN EmnwM50%gmmin8u SW Tyree SW DA50-IMRO wllh Nl NIg1R50%Dineri AFA Networkwern(SileWie) SW imapa niomilem Aulb Rok Pow AFR-90 SW-IMRO Pole p0uketlrmnon Aulb Front Row, daponsawfien Rolatedleft90' Weveleassykem AFRZO LLC2 InNgralrmdulewiNA2letsw A�FakRcwr fLCI Ikegralmo0ubwiNA3lens'e R arMrigllt2A0' LtC4 Ike8ralmatlulevdNA4ler¢'e onq on szu, zu& z4u, and zn (or umn L SpernyVIXtage 3. Not avalaNe wits 347 or zee voltage 4. HIS war avaabia with Type S or SIN bplira S DO is repulred for LICR and able Maunl monde serrrar, Ormminer Wads are au aided through Cab of lumiraia. Must be widened sidemotely(See accessories page) ECF-6-Gen2 06/17 pagelOf9 b. DEC an d LLCL314 not aval able with a ny Other mnlrols 7. landtswelablewnh OCC B. ECFIMRIpulpPMd ilh.lb.,ded,e.1h.S1n,when vdltigelo Will l42-4BOW 9. Mounrsloa4'rdund P01evthm pWrinciudedfdr spuarepoled. 10. Not mailable with SF and W5. RPM provided with black finish :wndard 11. Llmltedtda mavlmumaldSdeAreesalminA abweborlMnta R. 5WPP11onlsnotavailablewlIMR17. de -IMRloptlons wWIhevcitlism lINRIL IMR11and5W-INflOmdion responseMllons 13. AvaWWednlyon ROVantl2rlV Jescd tioo: 28' TYPE I CA CONCRETE POLES 20' AFG Type: �' SESCO Lighting I p ( , ISL1 ' Ill 6Lotgsn Road, R. taude,dve, R)3326 project: TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G n�Rir,� Tdt� ).N-%U h.:t„-+lae.sm Notes: JOB NO: PROJECT: CUSTOMER: #8 GROUND WIRE LENGTH OF POLE 2 5' $ Ff. STANDARD PIPE TENON SIZE _Nominal. Diameter Outside Diameter 2" 2.3/8" 3" 3 I/2" 3 1/2" 4" 4e 4 1/,Zn IN.E. Street Pompano Beachach,, FI 33064 PHONE: (954) 781-4040 (800) 749-4041 Pre —Cast Specialties, Inc. FAX: (954) 781-3539 SALES & ADMINISTRATNE Precast and Prestressed Concrete IN.E. Street Pompano Beachach,, FI 33064 PHONE: (954) 781-4040 (800) 749-4041 Pre —Cast Specialties, Inc. FAX: (954) 781-3539 SALES & ADMINISTRATNE Precast and Prestressed Concrete s{i ' desed bon: ECFS-32L-1A-NW-G2-AR-4-UNV-BZ-PTF2 Type: i? SESCO Lighting I Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G S U ]I71M 09)eaa0, it—OpiQa!e,R3]326 ) 7eE isuto+3im rm:{rp}.wam Notes: ECF-S EcoForm small Site & Area Optical Orientation Information Standard Optic Position Optic Rotated Left (900) Optic Position Luminaires ordered with asymmetric optical systems in the standard Luminaires ordered with optical systems in the Optic Rotated Left(90°) optic position will have the optical system oriented as shown below: optic position will have the optical system oriented as shown below (Type 5 and 5W optics are not available with factory set rotatable optics): Left side Right side 1 of pole of pole Street Side I ° •O- -O , Curbline 90° 2]O• House Side� - - O o° O Note: The hand hole will normally be located on the pole at the 0• point .... Optic Rotated Right (2700) Optic Position Luminaires ordered with optical systems in the Optic Rotated Right (270•) optic position will have the optical system oriented as shown below (Type 5 and 5W optics are not available with factory set rotatable optics): Left side I I Rightside of pole --- *� of pole Street Side I Curbline g0• House Side 0° Note: The hand hole will normally be located on the pate at the 0° point ECF-SGen2 06/17 page8of9 Street Side I Curbline House 511 Leftside I I Right side of pole of pole 90° 0• Note: The hand hole will normally be located on the pole at the 0° point. 270• Twin Lumina!re Assemblies with Type-90/Type-2]0 Rotated Optical Systems Twin luminaire assemblies Installed with rotated optical systems are an excellent way to direct light toward the Interior of the site (Street Side) without additional equipment It Is Important, however, that care be exercised to Insure that luminaires are installed to the proper location. Leftside Right side of pole of pole 180° Luminairewith Type-270 Street Side 270° Curbline House Side Luminaires with Optic Rotated Right (270' are installed on the LEFT Side of Pole Note: The hand hole location will depend on the drilling configuration ordered for the pole. Luminaire with Type-90 •1 1 I Luminaires with Optic Rotated Left (90°) are installed on the RIGHT Side of Pole w.s ueacription: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting I pro reject- TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G )J)6&(sS`)1n`5o Ft.Lauderdale,iL 32326 ) i mr' nt l4stl o+sun rm:lssgn+�am Notes: ECF-S EcoForm small Site & Area Specifications Housing One piece die cast aluminum housing with integral arm and separate,self retained hinged. one piece die cast door frame. IF Rating LED light engine rated IP66. Driver compartment rated to IP65. Vibration resistance ECOFOrrm with Standard Arm carries a 3G vibration rating that conforms to standards set forth by ANSI C136.31. Testing includes vibration to 3G acceleration in three axes, all performed on the same luminaire. Electrical Driver efficiency (-90%standard). 120-480V available (restrictions apply). Open/short circuit protection. Optional 0-10V dimming to 10% power. ROHS compliant. Surge protector standard. 1OKA per AN 062.41.2. LED Board and Array 32, 48, or 64 LEDs. Color temperatures: 3000K -/-125K, 4000K, SOCOK a/- 200K. Minimum CRI of 70. Aluminum metal clad board. RoHS compliant. LED Thermal management The housing design allows the one piece_ housing to proWde excellent thermal management critical to long LED system life Energy saving benefits System efficacy up to 1331ms/W with significant energy savings over Pulse Start Metal Halide luminaires. Optional control options provide added energy savings during unoccupied periods. SiteWise network system SiteWise system Includes a controller fully Integrated In the luminaire that enables the Luminaires to communicate with a dimming signal transmitter cabinet located on site using Philips patented central dimming technology. A Locally accessible mobile app allows users to access the system and set functionalltles such as ON/OFF, dimming levels and scheduling. SiteWise is available with motion response options in order to bring the Light back to 100%when motion is detected. Additional functionalities are available such as communication with indoor lighting and connection to BMS systems. Wireless system EcoForm luminaires are available with optional wireless controllers ready to be connected to a Limelight system (sold by other). The system allows you to wlrelessly manage the entire site, independent lighting groups or individual luminaires while on -site or remotely. Based on a high density mesh network with an easy to use web -based portal, you can conveniently access, monitor and manage your lighting network remotely. Wireless controls can be combined with site and area, pedestrian, and parking garage Luminaires as well, for a completely connected outdoor solution. Optical systems Type 2, 3, 4, 5, SW, and AFR distributions available. Internal Shield option mounts to LED optics and is available with Type 2, 3, 4, and AFR distributions to control backlight Types 2, 3, 4, and AFR, when specified and used as rotated, are factory set only. Mounting Standard luminalre arm mounts to 4- round poles. Square pole adapter included with every luminal re. Round Pole Adapter (RPA) required for 3-3.9' poles. Type: SU Retrofit Arm Mount EcoForm features an Innovative retrofit arm kit When specified with the retrofit arm (RAM) option. EcoForm seamlessLy simplifies site conversions to LED by eliminating the need for additional pole drilLing on most existing poles. RAM will be boxed separately. Listings U L/CUL listed to the UL 1598 standard, suitable for Wet Locations. Suitable for use In amblents from -40'to 40'C (-40-to 104-F). The quality systems of this facility have been registered by UL to the 1509001 series standards. Most EcoForm configurations are DesignLights Consortiums qualified, Consult DLC Qualified Products list for more details. Finish Each standard color luminalre receives a fade and abrasion resistant, electrostatically applied, thermally cured. triglycidal Isocyanurate (TGIC) textured polyester powdercoat finish. Standard colors include bronze (BZ), black (BK), white (W H), dark gray OGY), and medium gray(MGY). Consult factory for specs on optional or custom colors. Warranty EcoForm luminaires feature a 5 year Limited warranty. Philips Gardco LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED Drivers also carry a 5 year limited warranty. Motion sensors are covered by warranty for 5 years by the motion sensor manufacturer. O 2017 Philips Lighting Holding B.V. All rights reserved. Philips Lighting North America Corporation Philips reserves the right to make changes in specifications r r 200 Franklin Square Drive, Somerset, NJ 08873 and/or to discontinue any product at any time without notice Tel. 855-486-2216 or obligation and will not be liable for any consequences resulting from the use of this publication. Philips Lighting Canada Ltd. phillps.com/luminaires 281 Hillmount Rd. Markham. ON, Canada L6C 253 TeL800-668-9008 ECF-5Gen2 06/17 page9of9 bescdption: ECF-S-32L-IA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting I project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G ]3T Srn Ush Road,a tautlerdale, FL A316 /Iy3v5. Tmd9spe+a3M Notes: ECF-S EcoForm small Site & Area EcoForm Accessories (ordered separately, field installed) CmtrdsAmesunes seddr,Acarnewmau Pole Mount Motion Sensor MS-A-1201U" 120VInput MS-A-27I 2)N input Wirelesssysfems Rematemoun eradule LLCB2-(F)) #21ens LLCR3-(F) #31ens LLCR4-(F)- Polaris Central Remote Motion Response l,nol onnectM W SRewlu main panen M52-A-FVR-3 M53-A-FVR-7 R,Ooaptlanreauired 12. Notavaili biewithType Sor SW optics House STdeshield Standard Orientation: HIS-32-Ho Internal House Side Shield for 32 LEDs(2 modules) HIS-48-11a Internal House Side Shield for 48 LEDs(3 modules) HL9-64-Hu Internal House Side Shield for 64 LEDs(4 modules) At90o1270o1ienpborn 11I5-1!-Via Internal House Side Shieldfor32LEDs(2m0dules) HIS4B-V- Internal House Side Shield for 48 LEDs (3 mad.[.) HIS-6442 Internal House Side Shield for 64 LEDs(4 modules) Type: SL2 ECF-BB-G2- Bird demount PM-(F) Pole pOfi[lerfits 23/B-2l/2-CDx4-depth tenon with 12.3 or 4luminaires at90' PTF3-(F) Pole top fitter fits 3-31/2'DD x 6"depth tenon with 1.2.3 or 4luminaires at SO' PTF4-(F) Pole tap fitter fits 3 V2-4'ODx6-depth tenon with 1, 2.3 or 4luminaires atSO- ECF-SF-G2-(Fj SOP Fitter Mount (fits to 23/8.O.D. tenon) ECF-RA1Y1-G2-(F) Retrofit Arm mount kit ECF-WS-G2-(F) Well mountwiUl surface conduit rear entrypermitted (F)=Specify finish Predicted Lumen Depreciation Data Predicted performance derived from LED manufacturer's data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditionsLM Is the predicted time when LED performance depreciates to 70%of Initial lumen output Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours 2YC UP to 1200 MA I >100,000 hours LED Wattage and Lumen Values OMem,cede Total IEN LED Current (MA1 Color Tempi Average system Watts' Typal Type3 Type 4 lumen Oulputu BUG Rating EfM1mdl. Viol Lumen Output" I BUG Rating DAmry (LPW) Lumen Ouput'° BUG PaNng gland, (LPW) ECFS32L-53o-NW-GV. _32 530 4000., 56'- '6.864 82-UC-62 123 6T5' 1 BI-UOG2. ID 7,025 91-UG-GZ 126.' ECF-S-32L-)00-NW-G3-a 32 700 4000 33 8.853 BZ-UO.G2 121 8.661 B2-U0-G2 119 9.062 BI-UD-G2 124 ECF-5-32L1A NW-G2-x 32 1050 4000 1W -14464 B3-UO-G2 110 12J04 02H10-G2 115 ' 12.)5) B2-UO-G3 121.-, ECF-S-32L-l3-NW-G2-x 32 1200 4000 22 13,826 33-UO-G3 114 13.526 82-00-G3 ill 14JSI B2-1.10-33 116 ECF5 48L-960-NWdG3-i _ 40 Soo rood US 16,409 _ B3`1,10-0 .121 16053 _ B2-UO-G3 , 119 16795 52-UO-G3 124 So`S-48L-U-NW-G2-x 48 1050 4000 IS) 18.581 B3-UO-G3 ID I8,1)8 B3-U0-G3 115 19,018 32-1.0-G4 120 ECFS 40L 13A-NW?GZa d0 I200' '4000. 183 20,627 B3-UO-G3 '1113 20.3W B3-U0=G4 110 21JI2 B3-UO-G4 116 ECF-S-fi4L-900-NW-GTx lid 900 400n ITS 21.717 03-UO-G3 122 21,246 B3-U0-G4 119 22,228 B3-U0-G4 125 EGF$-fi4LN NWFGI-x '64 '1050 <d00 .M6 24,467 B3-UO.G3 IS 23,936' B3-UOG,l ITS 25,043 B3-U0-G4 122— ONedng Cade Tend Kos LEO Current (TA) Color Temps Average System Watte Types Type Sw Type AFR Lumen OAPuVz BUG RatinE Elcso, (LPW) Lumen Behold BUG -Rating Elfimry (LPW) Lumen Output" BUG RaNnr, Er�mey RPW) ECF-S-32L-530-NW-G2a [ 32 530 40M 56 7.414 B3-UO-G2 .. 133 7,125 B3-U0-G2 129 7.111 S2-UO-G1 1 128 , Eli-S-32L-700-NW-62-a 32 700 4000 A 9.563 B3-UO-G2 131 9,255 EWUO-G2 122 9,172 B2-UO-GI 126 ECF-5-321.11-11W-G2-i 31. 1050 4000 lots'. 13,462 B4-1.0-62 127 - D,U30 - MTUO-G2 in '12.912 B3410-G2 _ V2 ECF-S-3ZL-L2A-NW-GZ-x 32 1200 4000 p2 14,933 B44UG-G2 123 1,1,653 84-00-G2 119 14.322 B3-UO-G2 118 Eff-5-40L-900'xw-G2a 48 900 4003 US '1;R3 B4-UO-G2 331 I1,354 85-UO-0 127 16,999 8 U0-G2 126_ ECF-S-48L-IA-11W-G2-a 48 1050 4000 39 20,069 B5-OD-G3 126 19424 B5-UO-G3 D2 19.248 B3-UO-G2 DI EC-481.-LZA-NW-G2-rc 40 000 d000. 103 22219 BS UO-G3 122. 21.563 B5-UO-G3 118 21,368 - BIUO-GU V7 ECF-5-fi4L-900-NW-62-x 14 900 4000 110 23,456 B5-UO-G3 132 12.T02 B5-U0-G3 128 22,497 B3-OG-G2 127 ECF-S-fi4L-4-NW-G2d; 64- '1050 4000 206 26.4221 35�UO-G3 US 1 25,572 BS-UO-Ea 124 25346 E3-00-G2 - 123 " 1. Wattage and Wmen output may vary due to LED manufacturer toward volt specification 1 Lumen valueslrased on photometric tests performed In compliance with IESNA LAld9. and ambient temperature. 3, Warm white color temperature will result In dedeased lumen output. Wattage shown B average for 120V through 27N Input. Measuredwatmgemaywrldue ConlactoutdoorlfghUng.aoUmtioM pNNpscomfocdetailsoraddiftowlinformatlon. to variation in input voltage. ECF-8 Gen2 06/17 page2o(9 Oescri tlon: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 Type: 7s SESCO Lighting p ISL2 -y is 7p 9ims9un.,na r—('sr..+v133326 (Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS #'I6-3549G +c` rmS9s+J+r+3+%9 rm: {ss+t+:+.am Notes: ECF-5 EcoForm small Site & Area Dimensions Standard Arm (AR) Weight 22 Lbs(99 Kg) EPA 0.21ft1(019mT 60' 02hmj 275 (69.7cm) Retrofit Arm (RAM) Weight 24 Lbs 009 Kg) EPA 0.24fP(022w) 65" 1,15 ) 287"(73m) Outboard IMR-HVU sensor 1' p9cm1 Y7' 01.9.) ECF-6Gen2 06/17 page3of9 Wall (WS) Weight 270s.012Kg) EPA0.2719(025m9 6S 06.km) 393'Qd Scm) Slip fitter (SF) Weight 27LbsQ21 Kg) EPA 033f'(031m9 Standard Arm (AR) Retrofit Arm (RAM) drill pattern drill pattern om no Pi A. R RSmU IP Rs�ml PAN a.r nwun _�w1 yr IUespdpfiono ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-P' ing Type: SESCO LightProject TCERDASUNSHINE KITCHEN FOOD BUSINESS#16-3649G OS�2 7376hot9un Rod, Ft. teuderdaie, FL 33326 nT raiss,)4.,nia ra<:(fsnN<4tn Notes: ECF-5 EcoForm small Site & Area Luminaire options Do:0-10V dimming driver with leads supplied through back of Luminaire (for secondary dimming controls by others). TLRDS: TMst Lock Receptacle with 5 pins enabling dimming, can be used with a twistlock photoelectric cell or a shorting cap. Can also be used with Philips or third party control system. Receptacle located on top of fummaire housing. TLRD7: Twist Lock Receptacle with 7 pins enabling dimming and additional functionality (by others), can be used with twlstlock photoelectric cell or a shorting cap. Can also be used with Philips or third party control system. Receptacle located on top of luminaire housing TLRDPC: Receptacle with twistiock photoelectric cell (must specify voltage). Receptacle located on top of luminaire housing. Dynadimmer Automatic Profile Dimming: Automatic dimming profiles (CS50/CM50/ CE50) offer safety, median, or economy settings, for shorter or longer duration. Dimming profiles provide flexibility towards energy savings goals while optimizing light Levels during specific dark hours. 50% dimming is standard. DA50 offers 50% instantaneous dimming all night (during all dark hours). 75 % and 25%dimming is also available it different dimming Profile with sensor detection, where DOC: Dual Circuit Control permits separate the PIR sensor will override the dimming profile switching of a specific number of LED when occupancy is detected. Passive infrared modules. Available as an option with2 (PIR) motion sensor. through 4 modules. HARD: Infrared Motion Response Outboard Pole mounted sensor• must be specified with an available automatic profile dimming option. Combines the benefits of both automatic profile dimming and motion response using the Philips DynaDimmer technology. PIR sensor features a pole mounted Wanstopper EW-200-120-W or the EW-200-277-W. One motion sensor per pole is required (order MS-A-120 or MS-A-277 separately). Available In 120 or 277V only. IMRO sensors require single voltage 120V or 277V input (see chart for approximate detection Patterns). If motion is detected during the time that the luminaire is operating at profile dimming mode specified• the luminaire returns to 100%power and light output The luminaire remains on high until no motion is detected for the duration period• after which the luminaire returns back to automatic profile dimming. Duration period Is factory set at 15 minutes, and is field adjustable from 5 minutes up to 15 minutes. The area motion detector provides coverage equal to up to 6 times the sensor height above ground, 270' from the front -center of the sensor. SW: SlteWlse option Is a fully integrated controller that connects to Philips Siteivise system in order to offer a complete area lighting management system. The communication signal is based on Philips patented central dimming technology. SiteWise delivers it deliver optimal energy savings using your site's existing cabling. No additional wiring required, installation and commissioning are simple. An intuitive, mobile app makes It easy for authorized users to set schedules to meet site specific lighting needs. local regulations, and energy codes. Wireless systems: Controller radio/sensor module attached to luminalre arm and Includes radio. photocell and motion sensor. Available with #2 lens (LLC2) for 8' to 15' mounting height" or #3 lens (LLC3) for 15-25' mounting heights or#4 lens(LLC4) for 25- ' 40' mounting heights. Also available with remote pod accessory where pod Is mounted separate from luminaire to pole or wall (see accessories and wireless system Information page 5-7). light levels are required (contact Technical Pole Details: IMRO requires that the pole FI: Fusing Single (for 120. 277 or 347VAC) ,...._-Supportfordetails). ... Include an additional hand hole 15 feet above "' - '- .. "- thepolebase, normally oriented 180'to tF2: Fusing Double (far 208, 240 pr 480VAQ _ the standard hand hole. For Philips Gardco FP7: Fusing Pole Single Economy 50% 9hours 9PM-6AM poles, order the pole with the Motion Sensor (pole mounted new handhole: Median 50% ehours IOPM-6AM 270°Front Coverage for 120, 277 or 347VAC) Safety 50% ]hours 11 PM-6AM Distances are FP2: Fusing Pole Double 'Reactive 50 50% dynamic atlnight / approximate. (pole mounted near handhole, 90° H= helghtabove ground for 208,240 or 480VAC). HARD, IMRD: Infrared Motion Response Height Integral. IMRI module is mounted integral on FP3: Fusing Pole Canadian Double Pull driver door and is available with two different iH 3H 6H (pole mounted near handhole, sensor lens types to accommodate various far 208, 240 or 480VAC) mounting heights and occupancy detection ranges (see charts for approximate detection patterns on page 7). Motion response used in combination of Dynadimmer and SiteWise are not programmable and used to override controllers schedule when motion is detected. When used not combined with any controller, IMRI is set/operates in the following fashion: The motion sensor is set ro a constant 50%. When motion is detected by the PIR sensor, the luminalre returns to full power/Light output Dimming on low is factory set he 50% with 5 minute default In 'full power' prior to dimming back to low. When no motion is detected for 5 minutes, the motion response system reduces the wattage by 50%, to 50% of the normal constant wattage reducing the Light level. IMRI can also be specified with automatic profile dimming for the added benefit of a combined ECF-5 Gen2 06/17 page 4 of 9 Mounting (MSM) option which Includes the hand hole and a special hand hole cover plate for the sensor with a 1/2' NPT receptacle centered on the hand hole cover plate into which the motion sensor mounts. Once the motion sensor is connected to the hand hole cover plate, then wiring connections are completed in the pole. The plate (complete with motion sensor attached and wired) Is then mounted to the hand hole. If poles are supplied by others, the customer Is responsible for providing suitable mounting accommodations for the motion sensor in the pole (see Gardco Poles specification sheets for more information). SPI: Surge Protection, IOkV/SkA, 120-277V or 347-480V SP2: Surge Protection, 201 120-277V or 347-480V HIS: Internal House Side Shield.Injection molded in black finish. Ships installed with 1 per 16 LED module. Also available shipped separately as an accessory for 2-4 LED modules. A '` SESCO Lighting 7P.snprgun goad, it. lauEtt4a!e, R Xd76 tllgr T2 ixa;ewssm ra.:(mal na-3n] description: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 Typo: Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3649G S L2 Notes: ECF-S EcoForm small Site & Area Wireless system — luminaire configuration information LLC2/LLC3/LLC4 Luminaire Mounted Controller Controller pod attached to luminalre and Includes radio. photocell and motion sensor with#2, 93 or #4 lens for 8-40' mounting heights. Recommended Sensor by Pole Height 40 35' 3U 25' 20, 15, LLC2I LLC3 LLC4—�{ Wireless system sensor ECF-5_Gen2 06/17 page5ot9 LLCR2/LLCR3/LLCR4 Pole Mounted Controller Remote Mount Wireless Controller In this configuration, the wireless controller wig be mounted to the pole at a fifteen foot mounting height. The number of luminaires on each pole. as well as the specific wattage chosen, will determine how many controllers wilt be required. When using the wireless remote accessory option (LLCR-F) in a pole mount apptication, specify pote option (CL-Coupi!ng Internet Thread, 3/4' size). Confirm required orientation of Wminaire and wireless controgef. Indicate height above pole base and orientation to hand hole. Recommended min pole height is 18f , with option (CL)15ft above pole base. Other heights are possible when choosing the appropriate sensor lens type. See pole specification sheets for more Information. 1. Photocell - Ambient light photocell on every wireless' radio that averages the light levels of up to 5 controllers for an accurate reading and optimal Light harvesting activity. - Reports ambient light readings to 1500 Fc. 2. Motion Response - Detects motion through passive Infrared sensing technology with three different lens configurations. - Motion sensor coverage can be adjusted from a narrow to a wide detection range, which helps reduce false triggers to further increase energy savings. - Sensing profiles can be updated to adapt to activity levels In the environment. such as occupancy level, wind, and mounting height. Used to extend the communication on site, to extend motion response and add other luminaires that are not pole mounted. Consult factory for more information. 3. Wireless Radio 21.8 Watts max (no load draw) - Operating voltage 120-277 VAC RMS - Communicates using the ZigBee protocol - Carries out dimming commands from Gateway - Reports ambient light readings to 1500 Ft-Cd - Transmission Systems Operating within the band 2400-2483.SMhz - ROHS Compliant Ali Description: ECF-S-32L-IA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting p 737Eat90a mad, F[. tauderQale, 1113326 Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G 11M�� Teosn42d9a#'raai96e'42441. N0205: ECF-S EcoForm small Site & Area Infrared Motion Response — Coverage Patterns LLC2/LLCR2 30' Luminaire or remote mount controller with #glens 30 IV 0' In 1. 11' T 3'0'3' T II' 24' IMR13/LLC3/LLCR3 Luminaire or Remote mount controller with #3 lens 11111%' 1211111 111WHI MN59®1% ®NEWH►NN11e 2b IV 15n' V 6' 3' 0 3' 6' 9' 12' 15' IV 20' LLC4/LLCR4 Luminaire or Remote mount controller with #4lens 0 10' 20' !iw 30.//� 30' 20' 12' fi 0 6' 12' 20' 3n :a la' a' 10' 20' I ait 1 30' 2T 20' 12' 6'3'0TV 12' 20' 2T 30' MRI7 Integral motion response with #7lens 40' — 50' 40' 30' 20' 10' 0 lb 20' 30' 40' SW ECF-SGen2 06/17 page609 SL2 atir IOeSeri ption: ECFS-32L-1A-NW-G2-AR-4-UNV-BZ-PTF2 Type: SE9C0 Lighting Project TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G S L2 'a ]Sl Fatqun goaC, Ft. tauderCale. iL37316 qr�,a nsi lara:nue Tm: isuf41"M Notes: ECF-S EcoForm small Site & Area SiteWise system SiteWise is a complete area lighting management system including a lummalre Integrated controller, dimming signal transmitter cabinet, and locally accessible user Interface. Installation and commissioning are simple. The cabinet communicates With the Philips luminaires using a patented central dimming technology. The control signal is embedded on the existing electrical line —no new cabling Is required. An Intuitive, locally accessible interface makes it easy for authorized users to set schedules in order to meet site Specific lighting needs, local regulations, and energy codes. SiteWise system diagram o° e n n I r. Gateway • . ..... {i@naE. `. transmitter' aria Y hansfarmev SiteWise system interface SiteWise hasan intuitive user Interface that makes it easy to plan, edit, and Implement lighting schedules for your site. Authorized users can access the Interface via a local app. To ensure that only authorized users can access your lighting. SiteWise offers two user types, each with different permissions. An advanced user, or administrator, can set and edit schedules using the ten pre-set €� w scenes. assign those schedules to calendar days, and check system status. For everyday use, a basic user can manually override a schedule that is currently running but cannot create or edit schedules. ( SiteWise system specifications The SiteWise system includes both luminaires and controls. The controls used for SiteWise are circuit load dependent Required for a complete Installation are the Following Philips SiteWise components: user interface, control kit, dimming signet transmitter cabinet, and dimming signal receiver located in She Philips luminalre (SW option). Optional luminafre-Integrated or external motion sensors may also be specified as required. Within the electrical closet, the control kit and dimming signal transmitter cabinet are installed into the electrical system between the existing breaker panel and the site luminaires. New LED luminaires containing the dimming signal receiver are Installed on the site. Once completed, use of the Interface allows for scheduling and override capabilities. Wireless access point and tablet should be supplied by others. Complete information on the control system can be found on the SiteWise website at phillps.com/sitewise ECF-a Gen3 06/I7 page7oi9 SESCO Lighting Description: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 737 St10ngur, Read, ft. Lauderdale, FL 33336 (Project: TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16-3549G t 'epa rymana-rw:(oui'H.em Notes: ECF-S EcoForm small Site & Area Optical Orientation Information Type: SL2 Standard Optic Position Optic Rotated Left (90') Optic Position Luminaires ordered with asymmetric optical systems in the standard Luminaires ordered with optical systems in the Optic Rotated Left(90') optic position will have the optical system oriented as shown below: optic position will have the optics[ system oriented as shown below (Type 5 and SW optics are not available with factory set rotatable optics): Leftside Right side 1 of pole of pole Street Side I •, O O Curbline g0' 270' House Side 1 0 0 0. Note: The hand hole will normally be located on the pole at the 0' point Optic Rotated Right (2706) Optic Position Luminaires ordered with optical systems in the Optic Rotated Right (270') optic position will have the optical system oriented as shown below (Type 5 and SW optics are not available with factory set rotatable optics): Leftside I I Right side of pole of pole Street Side I Curbline 90' House Side Note: The hand hole will normally be located on the pole at the 0' point ECF-5_Gen2 06/17 page6ai9 270' Street Side t Curbs ne House Sldel Left side I Right side of pole of pole 90' RSi Note: The hand hole will normally be located on the pole at the G' point 270' Twin Lurnmaire Assemblies with Type-90/Type-270 , Rotated Optical Systems Twin Wminaire assemblies installed with rotated optical systems are an excellent way to direct light toward the Interior of the site (Street Side) without additional equipment. It is Important, however, that care be exercised to Insure that Luminaires are Installed In the proper location. Leftside Right side of pole of pole Luminairewith Type-270 Street Side/ Curbline T House Side I ' 180' 0' 0' th Luminaires with Optic Luminaires with Optic Rotated Right(270') are Rotated Left (90°)are installed on the LEFT Installed on the RIGHT Side of Pole Side of Pate Note: The hand hole location will depend on the drilling configuration ordered far the pole. uescrlption: ECF-S-32L-lA-NW-G2-AR-4-UNV-BZ-PTF2 SESCO Lighting ProJept: TCERDA SUNSHINE KITCHEN FOOD BUSINESS # 16.3549G )J)shatevn,M,5 FLtav0erdsle,fLJJ326 npcw m:tss.)nns a rm Rsant4m Notes: ECF-S EcoForm small Site & Area Specifications Housing One piece die cast aluminum housing with Integral arm and separate,self retained hinged, one piece die cast door frame. IP Rating LED light engine rated IP66. Driver compartment rated to IP55. Vibration resistance EcoForm with Standard Arm carries a 3G vibration rating that conforms to standards set forth by ANSI C136.31. Testing Includes vibration to 3G acceleration in three axes, all performed on the same luminalre. Electrical Driver efficiency (�S 0%standard). 120-480V available (restrictions apply). Open/short circuit protection. Optional 0-10V dimming to 10%power. RoHS compliant. Surge protector standard. 10KA per ANSVIEEE C62.41.2. LED Board and Array 32. 48, at 64 LEDs. Color temperatures 3000K +/-125K. 4000K, 5000K -/- 200K. Minimum CRI of 70, Aluminum metal clad board. RcHS compliant LED Thermal management The housing design allows me one place hbu3l dg to provide excellent thermal management critical to long LED system Life. Energy saving benefits System efficacy up to 1331ms/W with significant energy savings over Pulse Start Metal Halide luminaires. Optional control options provide added energy savings during unoccupied periods. SiteWise network system SiteWise system includes a controller fully Integrated in the Luminaire that enables the luminaires to communicate with a dimming signal transmitter cabinet located on site using Philips patented central dimming technology. A locally accessible mobile app allows users to access the system and set functionalities such as ON/OFF, dimming levels and scheduling. SiteWise Is available with motion response options in order to bring the light back to 100%when motion is detected, Additional functionalities are available such as communication with indoor lighting and connection to EMS systems. Wireless system EcoForm luminaires are available with optional wireless controllers ready to be connected to a Limelight system (sold by other). The system allows you to.wiretessly manage the entire site, Independent Lighting groups or individual luminaires while on -site or remotely. Based on a high density mesh network with an easy to use web -based portal, you can conveniently access, monitor and manage your lighting network remotely. Wireless controls can be combined with site and area, pedestrian. and parking garage luminaires as well, for a completely connected outdoor solution. Optical systems Type 2, 3, 4, 5, 5W, and AFR distributions available. Internal Shield option mounts to LED optics and is available with Type 2. 3, 4, and AFR distributions to control backilght Types 2, 3.4. and AFR, when specified and used as rotated, are factory set only. Mounting Standard luminaire arm mounts to 4° round poles. Square pole adapter included with every luminaire. Round Pole Adapter (RPA) required for 3-3.9"poles. SL2 Retrofit Arm Mount EcoForm features an Innovative retrofit arm kit. When specified with the retrofit arm (RAM) option. EcoForm seamlessly simplifies site conversions to LED by eliminating the need for additional pole drilling on most existing poles. RAM will be boxed separately. Listings UL/cUL listed to the UL 1598 standard, suitable for Wet Locations. Suitable for use in ambients from -40° to 4WC (-40° to 104`F). The quality systems of this facility have been registered by UL to the ISO 9001 series standards. Most EcoForm configurations are DesignLights Consortiums qualified. Consult DLC Qualified Products list for more details. Finish Each standard color luminaire receives a fade and abrasion resistant, electrostatically applied, thermallycured, trlglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard colors include bronze (BZ), black (BK). white (W H), dark gray (DGY), and medium gray(MGY). Consult factory for specs on optional or custom colors. Warranty EcaForm Luminaires feature a 5 year limited warranty. Philips Gardco LED luminaires with LED arrays feature a 5 year limited warranty- - - - covering the LED arrays. LED Drivers also carry a 5 year Limited warranty. Motion sensors are covered by warranty for 5 years by the motion sensor manufacturer. © 2017 Philips Lighting Holding B.V. Ail rights reserved. Philips Lighting North America Corporation Philips reserves the right to make changes in specifications a a 200 Franklin Square Drive, Somerset, NJ 08873 and/or to discontinue any product at any time without notice Tel. 855-486-2216 or obligation and will not be Emote for any consequences resulting from the use of this publication. Philips Lighting Canada Ltd. philips.com/luminalres 281 Hiltmount Rd, Markham. ON. Canada L6C 2S3 Tel. 800-668-9008 ECF-S_Gen2 06/9 page9of9 r SESCO Lighting Description: Project I 28' TYPE I OA CONCRETE POLES 20' AFG ) TCERDA SUNSHINE KITCHEN FOOD BUSINESS#16-3549G Type: SL2 ]I]Slwt9un Awn. it. tauCeMale.R33326 fia�n" rr,,(wyawwv Tar. Intl r,,em. Notes: JOB NO: PROJECT: CUSLOMER- #8 GROUND WIRE 5' STANDARD PIPE TENON u u II PI II II II 11 II II Il II e I I T' POLY PIPE I Abo�a embedment shown in send. I Other embedment depth may be o I I 3'x 5• HANG I I required for other soil -condition. I I ALUMINUM COVER N tt^^ F II W II z Ii II o _ 5 p » II 11 " II II m I ro Please order tenon by nominal diameter. 9 1/2- 28 ft. TYPE I-0 POLE LENGTH OF POLE 28 FT. EMBEDMENT �FT. SPECIFIED HEIGHT ABOVE 20 Fr. cEouND — tre:clrc 1530 LDs. �'!° vBcaarrtr 120 140 150 (mrh) MAXIMUMEPA- 9 4 3 (eq. ft.} STANDARD PIJ'E TENON SIZE Nominal. Diamotar, Outside Diameter 2" 2 3/8" 2 1/2" 2 7/8" 3" 3 1/2" 3 1/2" 4" 4" 4 1/2" 1mpa N.E. Beach, Street 3 Pompano Beech, FI 33064 PHONE: (954) 757-4040 Pre —Cast Specialties, Inc. (800) 749-4041 p FAX: (954) 781-3539 SALES & ADMINISTRATIVE Precast and Prestressed Concrete