HomeMy WebLinkAboutPROJECT INFORMATIONOF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT,IS'SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE ED 0 IS BUILDING BLOCK THE HIGH SPOT AND LEVELED. THE OTHER END OF THE N BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT '. SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. `5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE' UNIT HAS A FLOOR; EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. _THE EYEBOLT IS FASTENED THRU THE BOTi0_M PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20--0" 400 S- r 13'-8" 280 S-6' 11'-8" 240 T-r 10'-0" 200 S-61 8'-O" 160 S-67 6'-0" 120 S-67 TABLE 2 SKID RUNNER SPACING" SHED WIDTH X1 X2 X3 11'-8" 2'-B' 6--4" - 10'-0" V-7" 6'-10" - 8''" 0'-9" 6--64" - 6" 0'-10' 51" - 'VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4'x4' SKIDS ONLY. 13'-B' WIDE SHEDS HAVE (4) SETS OF SKIDS. 30" AUGER ANCHOR (4,900LB) SETUP AND INSTALLATION OF-DG, _ .E WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER,. AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL. BLOCKS ARE ADDED TO ACHIEVE R SPACING S EV EV THE CORRECT S N (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)�"x4j' BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS --REMOVED.- - 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER'DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD' MATERIAL I 2'x8"xi6' 177OL13S CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"xEl"x16" 350OL13S CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16"X16" 3950LBS ASS PLASTIC PADS N 8'xB"x16" 1900LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACOY (20CDPSF IS T(PICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (B"XVXIG-) MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON IV-B' AND 13'-B' WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0' TO G 6'-0- 1936L3 I, II, III, OR N 1879LB I, II, Ill. OR N I V-8" SW/DW 6.00/480 0" TO 6' 6'-0" 2558LB I, II, III, OR IV 2558113 I, II, III, OR N 10'-0" SW/DW 5.00/400 0- TO 6" 6'-0' 24COLB 1, 11. III, OR IV 2400LB I, II, III, OR N 8'-0" SW 4.00/320 0" TO 6• 6'-0" 2029LB I, II, III, OR IV 21331E I, II, III, OR N 6'-0" SW 3.00/240 O" TO 6' 6'-0" 1658LB I, II, III, OR IV 1866LB' I, II, III, OR N • LOAD WIDTH OF UPUFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. RECEIVED FEB 212018 ST. Lucie County, Permitting 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW UPUFT (PLF) END ANCHOR'- MAX. INTERIOR SPACING••• 13'-8" 7.00 243 U-cr m S-Cr 1 D'-O" 11,-8" 6.00 208 0'-0" TO S-O* 10'-0" 10'-0" 5.00 174 U-T TO S-T 10'-0" 8'-0" 4.00 138 U-T TO S-T 10'-0" 6'-0" 3.00 104 U-T TO S-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW UPUFT (PLF) I END ANCHOR" MAX. INTERIOR SPACING... 20'-0' 10.00 400 0'-0" TD S--0" • LOAD WIDTH OF UPLIFT ON RUNNER "Amno ::LOCATION FROM END WALL OF AUGER ANCHOR •• MAXIMUM SPACING BETWEEN ANCHORS al�n 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 8 r NOTES 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. ry@ 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNN IVDS ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0' BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE ODE AS POSSIBLE. T 2'x2' GALVANIZED WASHER 2'xY GALVANIZED WASHER WITH 1/2' NUT 1/2- THREADED ROD WITH 1/0 NUT OPTIONAL FOR 'HIGH ET' - NOTCH OR COUNTERSINK BOLT 1/2- THREADED ROD---,,,THRU EYES BOLTED TOGETHER VA2'x2' 2'x4' BOTTOM PLATE OPTIONAL FOR 'HIGH SEYBOLT G &NUT WTTH (2)Yx2' GALVANIZED 1/2' COUPLER BOTTOM PLATE NAILED 1/2' COUPLER WASHERS (2.000LB SHEAR CAPACITY) _ •^ 1/2'x5' LB.) CONCRETE TO 2's6' P.T. BASE TO 2 1/2-x12- FORGED EYEBOLT v -EN' MIN. NN WEDGE ANCHOR INTO SLAB - ------� MIN. THRU 2'x4P.T. BOTTOM CUTE I (SEE TABLE 1 fOR SPACMG).EYES BOLTED TOGETHER WITH 1/2'x2' BOLT & NUT WITH (2)2-x2- GALVANIZED j( TYPE I, II, 13, OR N PAD WITH BLOCKING AS REQUIRED (SEE TABLE 3). 1/2'x3' (400 LB.) �tJ'NCRETE SIMPSON A-2SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH WASHERS (2.000LB SHEAR CAPACITY)- • CONCRETE WEDGE ANCHOR CUP OR EQUAL LOCAL CODES AND JURISDICTION LOCAL CODES AND JURISDICTION JAY 30' EARTH AUGER ANCHOR -IV((, i (SEE TABLE 1 FOR SPACING) (SEE TABLE 4 FOR SPACING) SHED WITH SKID SHED WITH SKID SHED WITH 'NO FLOOR' OPTION TO PAD OR .BLOCKING ANCHORED TO CONCRETE ANCHORED TO CONCRETE TIE -DOWN DETAILS t'+ 4-. F LL-- 1P.-�.!L 1 yG CODE VF]tSON I Fee 2017 61N EdL"n, ASCE-7 MANDFACNREN Sxma 9¢M CONSTRUCTION TYPE V-B ME PROTECTION NONE ME SUPPFESSON S'r= NONE --- OCCUPANCY SroRAGE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED w-180inpn EXpDSURE c ENCLOSURE ENCLOSE] INTERNAL PRESSURE COEFFICIENT f/- 0.1E IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD foes ROOF LNE LOAD ;,OZ OR 300Re FLOOR DEAD LOAD aisF FLOOR LNE LEAD M 75PSF - 125FSF M. MODULES pER auuDlnc I 1 HURWfANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE IE4 THIN T1D SCR. (n - -... MTB p Deh: LLJ 4/26/16 = Scale: (n N/A oe6l I1J ALL GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. LJJ 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION J 1015.22. m 3. REFER TO TIE -DOWN DETAILS FOR PROPER D INSTALLATION REQUIREMENTS TO MEET CODE 0 \`�t111111T111//��� E........... EN (n i Li � Iv (' O • STATE OF ? /y AN FLORION J Matthew T. Baldwin P.E. Q Florida License #64608 �co� � z Sheet: AD-1 OF �PSIAPPROVAL2"- -01-18 r D4 ALUMINUM ROOF SHEATHING a I J 71.4 RUNNERS a D END WA TRUSS 3 .. 2'a4' TRUSS -O 24' O.C. :MAR:'`> i DESIGN PRESSURES ROOF +27.8 WALLS/UOORS/WINOOWS I +32.6 -292 ROOF FRAMING PLAN ELEVATION CROSS—SECTION TYPICAL ARCH FRAME ?a END ELEVATION WITH GARAGE DOOR (Owr ON amswJ Side Nfall Header Schedule (180C) Building Width Fasteners vd strap Size Up to 14• Wide raa„ e"." u Ohl (each end) I RMWWOCI Wdlues are Or No. 2 grade Spmce�Plne-Fir lember. NJ - Number ofiack studs required to support each and. Window header far window openings that have more than 50% combined stud wan abae d below, otherwise use dear header schedule. See header details for alternate layouts, Le. 2.2'k4' or 4°x4' P.T. The header can be attached to the top plate and thus have the combined strength uhmient and use the maximum span stated •t® 1. So rARmm srxEDu1E FOR xRROWARE I SEE NFACFA BaRGUE niR ILdItlW1 K 1 MNUOW MM16 MqE mTc11 WR Wt YNL SN.VMG AB0.[ AND DVI. onExAse RamSTR TO Goal IaAnaa WNE sn as , \ 9NnE EL• GNDWH%O li xume OR We MCR OR (RTha00 1 i 12112• OR +RN• BEIMFm ' L WMG As 1m 12' MAx. Nfc 95 HPINK IO , HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & & DOORS k0ELONALI DOOR 6' WIDE OR LESS G.F.I. T+ _NOTES-OPRONAL ELECTRIC OUTLET -ALL WIRING SHALL GAGE 3-WIRE MC CABLE SOURCE N 'I --ENCASE IN ALL METAL eoxFs. L " WIRING DIAGRAM (OPTIONAL) .9E RE/Lfll ov"a. W RaMIFA. GRAMME 2-W 4"x4" W/2"x4" ntertelt, psi EoOEREV,EW onmdo. nonao asaas a„x R.n..: vkm. c Nlxan vE nvEAnaTa,uvEwmtT 1wt¢Ewuss,m v5nmsaR ' 1 —a AWMWBU WNA SIeATYNf OPIe1S (fnvni'13' w�^�10° STANDARD WALL DETAIL '+ wU. FRWND UEVRERs ARE CONm+wus FROM aR EaW. WrrH DOOR & WINDOW OPDONS NONDFnON SILL TD ROOf N0 SECUiEO ip EMuft A cN11N ous uvo mni. WnmE WAu 4aSms aODa axrARFmc a/4- R1NWD .vE NOT WN WUOM. SNFET IaTA. C AUM. T at C11P5 - a/{' F.T. PLYAaoD SIWL BE M DF f VN'MD STM. OF Mss TUN aa(o' No 1NR]UiM - a/I' rK - a/{• P.T. TAG a-o- uAx x Si®'AOaI n 13 n IY-e• r-+d• r-1d• r-+vp tt•-e' r-e• er - t0'd- B'-0• L-Y Yb• _ 6'-0• C-iT el' - 9 , , I ,wm.r.mv Dmmmmmrtm vat {u• PmR aec v<ta v® w.x (o rm a am R 4 ' i d v.Tl. zO.G. OPPONA. 12PSF 0 1 e• O.C. rv, wall 4TRIG RBAR O P.T. XURF D w11H HM OR EOM'NmF. SEE Tl.@E 2 FOR OWMIIY Ale sPAEWa I I MANUFAMRS EUPEIJOR SIMS BIAIDING TYPE iVFACru m pmpENML U N SfORbE CONSTRUEl10N ME FIRE PROIECt10N NOW FIRE SUPPRESSOR SYSIEJ( NOW OCCUPANCY SNPAOE ALLOWASM NUMBER OF STORIES I WIC WINO SPEOR V—MaRPH E%POSURE a ENCLOSURE mLIDSED IMFANAL PRESSUI(E COEFFICIENT ♦/- D.te IMPORTANCE FACTOR 11.15 (ROOF M MAD ISOMSF OR a00IL PoWf LOAO II I FLOOR UYE LOAD Ism T FSF - MsMF, on. II W Z J Z 0, H ZLLI in LLJ d Ld W J a V) O U W LLJ O0 SoFT. OR MSS ON PEGS ARE Nor PAR OF T16 MAN SIT AND ME ZLn veP1DEM)N. D 6 N4 Tam" :Xo G! aNWEry.VbN 1 MOTOR Iola nE-WwN OE4N5 MR PROPER WST/WT]N 4 5PMF14 1RIIS�C ETe .VS L /z SPF. DRGK � Wm 1m u. Fr. M RAVE AN RO• MWuNU 1D BE OmAum ON -SITE BY OTHERS Tine WC& aw_5_AID DOORS m UEET Ta UWNuu sMECPlnmus _\CENSF •..• ly�i LLJ V) -T i �'t• STATE pQ F. Matthew T. Baldwin P.E. z Florida Ucense #64608 'm Sheet: SSB— I OF q I t' C -mot. •o"� .--`q .rs t �A4 i �+.5 xr :� i D zea•T 11"Wittim; •.zY .Y••• a rh