Loading...
HomeMy WebLinkAboutTESTING, ADJUSTING, & BALANCING REPORT41goa-os3a- PRO-DUCT SERVICES %no BLOWERDOOR&DUCTLEAKAGETESTING 3 010n7 .Is TESTING -ADJUSTING -BALANCING A8 C�1NNdoS TESTING, ADJUSTING & BALANCING REPORT for STAN WEEKS & ASSOCIATES EDWARM LANDING —BUILDING 15- 3200, 320$ 3204, 3206, 3208, 3W0 Morning Dew Lane Fort Pierce, FL 34982 APPROVE® July 9, 2019 JUL 15 2019 Permitting Department St. Lucie County, FL +++ ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES... 11 �r r 1 1jr�& Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductservicesJl@gmail.com 14 My 1 Ti 't. I,r!' �: 4 ",02104,k PRO -DUCT SERVICES BLOWER DOOR& DUCTLEAKAGETESTINO TESTING -ADJUSTING -BALANCING TEST & BALANCE INSTRUMENTS Evergreen Telemetry Capture Hood 151): Range: 100-2500 CFM Accuracy: +/- 3% Calibration: May 17, 2019 Evergreen Telemetry Capture Hood 8D-14: Range: 15-200 CFM Accuracy: +/- 3% Calibration: May 29, 2019 Evergreen Pressure/Velocity/Flow Sensing Module —Model S-PVF-1: Range: 1-2, 14-32 inches HG, 320 - 158' F Accuracy: +/- 3% Calibration: June 5, 2019 Evergreen Wrist Reporter WR-401 _ Pro -Duct Services Technician: Michael Faurot Certified NCI Contractor/Supervisor/Technician NCI Commercial Certification ID: 19-229-03 — Equipment re -calibration is performed as required by testing guidelines. — Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductservicesjl@gmail.com yn Alt.it 71 1- ZA a W Commer i air Mawr MICHAEL FAUROT Has successfully completed the required training and passed the written exam by the NdgM Comfort bsotate, Jul to perform HVAC commercial system balancing up to 20 tons according to NO practical standards and procedures. esfo Certified Since May 9, 2019 CertlfledvC as administered and recognized by (snmtMYAYButTO rcr.saxBtt �bmmeBO°� ^ t mrmm rnsttnrte,tnq Rob Falke, President Pro -Duct Services, 1915 Rio Vista R4 Fort Pierce, FL 34949 11 772,528.2076 pro-ductservicesJl@gmail.com 11 PRO -DUCT SERVICES BLOWERDOOR&DUCTLEAKAGETESTING TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3200 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type fise Design CFM Pre Test CFM FINAL CFN Entrance 1 CD 8 x 4 30 30 30 Kitchen/Living Rm 2 CD 10 x 30 160 174 161 Bathroom 3 CD 8 x 4 15 30 30 Bedroom 1 4 CD 12 x 8 180 129 181 Bedroom 2 Vent 1 5 CD 30 x 30 125 114 117 Bedroom 2 Vent 2 6 CD 30 x 30 125 112 118 TOTAL 635 637 FAN DATA Panasonic Whispergreen Model FV-05-11USK1 Vent Fan Mechanical components working as designed and match plan COMMENTS requirements. ... ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES.. Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 productservicesfl@gmail.com i v. r. "' ' y e f ' i 1 •'7o- t " , ;l _ r,,o,o_ I PRO-000T SERVICES BLOWE600011&DUCTLEAKAGETESTINO TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3202 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type file Design CFM Pre West CFM FINAL CFM Entrance 1 CD 8 x 4 30 31 31 Kitchen/Living Rm 2 CD 30 x 10 160 183 183 Bathroom 3 CD 8 x 4 15 32 32 Bedroom 1 4 CD 12 x 8 280 174 174 Bedroom 2 Vent 1 5 CD 10 x 30 125 127 127 Bedroom 2 Vent 2 6 CD 10 x 10 125 121 121 TOTAL 635 668 FAN DATA Panasonic Whispergreen Model FV-05-11USK1 Vent Fan Mechanical components working as designed and match plan COMMENTS requirements. +++ ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES... Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductservicesfl@gmail.com I IPA "�4_errw PRO=OUCT SERVICES BLOWERDOOR&DUCTLEAKAOETESTING TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3204 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type file Design CFN Pre Test CFN FINAL CFN Entrance 1 CD 8 x 4 30 39 37 Kitchen/Living Rm 2 CD .20 x 10 260 289 261 Bathroom 3 CD 8 x 4 15 38 27 Bedroom 1 4 CD 12 x 8 180 261 280 Bedroom 2 Vent 1 5 CD 10 x 30 225 220 112 Bedroom 2 Vent 2 6 CD 30 x 10 225 215 119 TOTAL 635 636 FAN DATA Panasonic Whispergreen Model FV-05-11USK1 Vent Fan _ Mechanical components working as designed and match plan requirements. +++ ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES +++ Pro -Duct Services, 1915 Rio Vista R4 Fort Pierce, FL 34949 772.528.2076 pro-ductservicesJla)gmaii.com I ) I c � i •al , � • ? .. I 9 _ sav', r i 4 y 'r9�• r J 4� 1• 'f ` l - I S !i Y"e r I•r • 5 k i. 5 '�� • 4 i } i 1 TP Y PRO -DUCT SERVICES BLOWERDOOR&DUCTLEAKAGETESTING TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3206 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type Size Design CFM Pre Test CFM FINAL CFM Entrance 1 CD 8 x 4 30 50 42 Kitchen/Living Rm 2 CD 10 x 30 160 173 170 Bathroom 3 CD 8 x 4 15 30 28 Bedroom 1 4 CD 12 x 8 180 176 176 Bedroom 2 Vent 1 5 CD 30 x 30 125 112 112 Bedroom 2 Vent 2 6 CD 10 x 10 125 110 110 TOTAL 635 638 FAN DATA - Panasonic Whispergreen Model FV-OS-IIUSKI Vent Fan Mechanical components working as designed and match plan COMMENTS requirements. +++ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NO STANDARDS AND PROCEDURES... Pro -Duct Services, 1915 Rio Vista R64 Fort Pierce, FL 34949 772.528.2076 pro-ductservicesJl@gmail.com Z7. ",0241tk PRO -DUCT SERVICES BLOWERDOOR&DUCTLEAKAOETESTING TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3208 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type Sine Design CFM Pre Test CFM FINAL CPU Entrance 1 CD 8 x 4 30 31 31 Kitchen/Living Rm 2 CD 30 x 10 160 191 181 Bathroom 3 CD 8 x 4 i5 27 28 Bedroom 1 4 CD 12 x 8 180 145 165 Bedroom 2 Vent 1 5 CD 10 x 10 125 101 119 Bedroom 2 Vent 2 6 CD 10 x 10 125 104 118 TOTAL 635 642 FAN DATA Panasonic Whispergreen Model FV-05-11USK1 Vent Fan Mechanical components working as designed and match plan COMMENTS requirements. +++ ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES.. Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductservices/I@gmail.com L2 11V Z_ ir 1z: PRO-OUCT SERVICES BLOWERDOOR&DUCTLEAKAOETESTING TESTING -ADJUSTING -BALANCING AIR OUTLET CHARACTERIZATION for STAN WEEKS & ASSOCIATES Edwards Landing —BUILDING 15 3210 Morning Dew Lane, Fort Pierce, FL 34982 Description Outlet Number Type Size Design CFM pre Test CFM FINAL CFM Entrance 1 CD 8 x 4 30 28 28 Kitchen/Living Rm 2 CD 10 x 10 160 181 176 Bathroom 3 CD 8 x 4 15 37 25 Bedroom 1 4 CD 12 x 8 180 157 177 Bedroom 2 Vent 1 5 CD 30 x 30 125 117 117 Bedroom 2 Vent 2 6 CD 10 x 10 125 102 313 TOTAL 635 636 FAN DATA Panasonic Whispergreen Model FV-05-11USK1 Vent Fan _ Mechanical components working as designed and match plan COMMENTS I requirements. +++ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES... Pro -Duct Services, 1915 Rio Vista RIt Fort Pierce, FL 34949 772.528.2076 pro-ductservicesJl@gmail.com � P P w � . � F �I ' .5;;( P ... _ + � _ 7 .I. � ... � . �.` _ ' _. ..�..� :ate: I � 9 t � ; '..;. "s i , - � 0 'Y_t. > � � s ' I l E s-G i I . � e y � � I ;� ,a , e i � i c� o- � P 4 + � � J � � 1 .,� i P � r . e �' s P 2 ) yi s� 6 i i : _� -mP. .. _. ... ' _ �.. -�' 1. ' _ � , s Nd s. . y � � 6 � t � a � i Y: 6 � _ - =y { t � .. B { - �. + . f ; y d e' �- ' d v z'�` ' �.� 'r � -:� �. r, ' r .I,�: .r .. � - .. � 'i _: r �- . � e i :: s � ' � � .. ' i J, J •� � � � � s s l _ _ ,° o ' r � � �^ . PRO -DUCT SERVICES BLOWERDOOR&DUCTLEAKAGETESTING TESTING -ADJUSTING -BALANCING TESTING, ADJUSTING, & BALANCING WARRANTY for Stan Weeks & Associates Edwards Landing —BUILDING is All Testing, Adjusting, & Balancing performed on this project by Pro -Duct Services is under warranty for a period of One Year from the date of completion of the Test & Balance, unless otherwise noted. Warranty will be considered null and void if another TAB company is brought in to evaluate the project without notifying Pro -Duct Services to be present at the time of the additional testing. Date of TAB Testing: 7/8/2019 Warranty Expiration Date: 7/31/2020 Pro -Duct Services Authorized Signature: Pro -Duct Services Technician: Michael Faurot Certified NCI Contractor/Supervisor/Technician NCI Commercial Certification ID: 19-229-03 BPI Certification ID: 5059122 ... ALL BALANCING WORK PERFORMED IN ACCORDANCE WITH NCI STANDARDS AND PROCEDURES+++ Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductservices,/l@gmaii.com ^13 is - I PRO -DUCT SERVICES BLOWERDOOR& DUCT LEAKAGE TESTING TESTI NG-ADJ USTI NG-BALANCING Pro -Duct Services, 1915 Rio Vista Rd, Fort Pierce, FL 34949 772.528.2076 pro-ductsemicesJl@gmaii.com 4T