Loading...
HomeMy WebLinkAboutPRESSURE CALCULATIONSr ENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 784-8550 www.floridaengineeringandtesting.com 250 S.W.1Yb Avenue Pompano Beach, FL 33069 DATE: 2/06/18 JOB ORDER #: 18-570 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Savannas Preserve GulfLok 7/8" Nailstrip Roof Panel ADDRESS: 9501 Gumbo Limbo Lane Jensen Beach, FL 34957 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height = Max. 15' Exposure: C Basic/Ultimate Wind Speed: Vait 170 mph Length = 54' Category: U Nominal Wind Speed: V�d=Vait*40.6 Width = 14' Slope: 3/12 = 14' (asd = allowable strength design) Parapet Wall: N/A Modular Home Kz = 0.85, Kzt = 1.0, Kd = 0.85 RECEIVED Design Calculations: Velocity Pressure: q = 0.00256*KZKtKdV2 FEB 2 2 2018 Velocity Pressure (it): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf ST. Lucie county, Permitting Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2] = 32.07 psf Width of Pressure Coefficient: Effective Wind Area: <1 Oft External Pressure Coefficient: 1) GCP1 = -0.9 2) GCP2 = -1.7 _3)� GCP3 = -2.6 0.1(14') = 1.4' 0.4(15') = 6.0' )use: 3'0" Design Pressures Based on Vasd: Internal Pressure Coefficient: 1) GCPi = 0.18 1) Field P1 = 32.07*[(-0.9) — (0.18)] _ -34.6 psf 2) Perimeter P2 = 32.07* [(-1.7) — (0.18)] _ -60.3 psf 3) Corners P3 = 32.07*[(-2.6) — (0.18)] _ -89.2 psf v Q Zi Quality'aA �6 JlZwurance Page 2, 2/06/18, Job Order`tti&570 All Area Roofing Savannas Preserve - Modular Home GulfLok 7/8" Nailstrip Roof Panel 9501 Gumbo Limbo Lane; Jensen Beach, FL: Attachment Requirements: FLO A Based on the requirements of Florida Product Approval # 11651.2 R3 with maximum design pressures of-52.5psf and-116.0psf; the following are our recommended fastening patterns to attach the maximum 16" coverage GulfLok Roof Panels to the minimum 15/32" thick, APA rated plywood deck (attached to supports per product approval) with one (1) # 10 -12x1" Pancake Type A fastener with minimum 1/4" penetration through the plywood as follows: Area Field Perimeter & Corner Maximum Total Uplift -52.5psf -116.Opsf Design Pressure Assembly A B 5-3/16" o.c. with'/4" to 5/16" diameter Panel Slot Fastener continuous bead of Titebond Spacing 5-3116" o.c. Weathermaster Metal Roof Sealant on the Male Rib Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 3'0" (Zone 2: Perimeter (including along ridges) is a 3'0" wide strip, Zone 3: Corners are 3'0" x 3'0") Contractor to verify that the fastening. patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with - Sincerely, .`0, ALale�Z Mark A. McOiwip, P.E. Florida Emitting *,gVting, h;c?'r ZZ Florida Reg. W02 of Certificate oleA I i9twook Y �//llllll�