Loading...
HomeMy WebLinkAboutCERTIFICATEPlanning & Development Services Department 4unoo alon-) -is Building & Code Regulations Division AS 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 03NNVOS Certification for Design Load Compliance Project Name: United Rentals Project Address: 7400 Commercial Circle, Fort Pierce, FL 34951 Permit #: II Construction Type: Wall Sign INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition using ASCE 7-10 2. Structure Designed as (check one): N/A Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 170 mph X ASD _LRFD End Zone Width: N/A ft 5. Mean Roof Height 30 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 80.7 Zone 2: 80.7 Zone 3: 80.7 Zone 4: 80.7 Zone 5: 80.7 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? N/A Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to ——complywith-the-applicable-structural.portions of the building codes_ currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design — — forces specified: John J. Orlando 0044089 Sigstature, •• STATE OF ♦t •' I/ BeyisgCN* Print Name Cert # & Co. Cent Auth. John J. Orlando PE LLC 165 Old Ridge Road, Macon, GA 31211 Company Name & Address