Loading...
HomeMy WebLinkAboutBUILDING PLANSAC ALTERNATING CURRENT A(C AIR CONDITIONING AL ALUMINUM AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTI C CONDUIT Cu COPPERCONDUCTOR COVE CRY OFVERO BEACH DC DIRECTCURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER S LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD CUGROUNDRODS HOLEAT EXISTING UTILITY POLE MTS MANUALTRANSFERSWITCH MLO MAIN LUGS ONLY NEC NATIONALELECTRICAL CODE NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON -SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGIDMETALCONDUIT RTU. ROOFTOPUNIT BE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY UG UNDERGROUND LION UNLESS OTHERWISE NOTED V VOLT VA VOLTAMPERE W WATT XFMR TRANSFORMER SCOPE OF WORK: • INSTALL 100 AMP METERIMAIN COMBO CAN ON 6' SQUARE CONCRETE POST. • INSTALL (2) 518N8' GROUND RODS. • RUN NEW CONDUIT AND BRANCH CIRCUITS UNDERGROUND TO COLUMN SHOWN ON THE PARTIAL SITE PLAN ON SHEET E2 • BRING NEW CONDUITAND BRANCH CIRCUITS UP COLUMN AND RUN ALONG STRUCTURAL BEAM TO COLUMN SHOWN THE PARTIAL SITE PLAN ON SHEET E2. BRING CONDUIT BACK DOWN AT PARKING SPACE 99 TO RECEPTACLES MOUNTED AT 66• ABOVE FINISHED FLOOR. • PROVIDE AND INSTALL(1) 14 011 AND (1)15-20R RECEPTACLES WITH WEATHER PROOF WHILE IN USE COVER. R ELECTRICAL LEGEND SURFACE MOUNT 120/204V, 10, 3-WIRE PANELBOARD .�EiuNOSQX x=31 — NEMARAING NON -FUSED DISCONNECT FLUSH MOUNT 120I204V, 10, 3-WIRE PANFIBOARD � NON DUE) FlLWES� �— SURFACE MOUNT 277/48OV, 30,4-WIRE PANELSOARD NUMRMN6 FUSEDDISCONNECT FLUSH MOUNT 27714BOV, 30, 4-WIRE PANELBOARD UTILITY METER CAN OR METER CAWOOMBO UNIT SURFACE MOUNTAUTOMATICTRANSFERSWITCH POINT OF NEW CONNECTION GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 11026. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 250. NO CALE ELECTRICAL RISER DIAGRAM GENERAL NOTES: 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. 2. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION OA 2'PVC UNDERGROUND SERVICE FEEDER WI(3)MIO THWN AL O UrPVC W/(1)94 BARE CU - © 1'PVCWI(3)06THHNCU,(1)UBTHHN CU GROUND /4unoo elowl gg-, AS Q3NNV9!5 STRUCTURAL BEAM (NEW)1430R AND 152011 RECEPTACLE AT PARKING SPACE 99 MOUNTED ON BACK SIDE OF COLUMN FACING TOWARDS PARKING SPACE 99. w GRADE Z' n. h U D_N UaLL� W Q Z m W m - N W U)lnrz m 0 0V'-w a] N ZL — Z79 F > Q W Z Q K J Z Q' �go LL NO ABBREVIATIONS AC ALTERNATING CURRENT MTS MANUAL TRANSFER SWITCH AID AIRCONDITIONING MU) MAIN LUGS ONLY AL ALUMINUM NEC NATIONAL ELECTRICAL CODE AHU AIR HANDLING UNIT NTS NOTTO SCALE ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION AFGI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NON -SE NON SERVICE ENTRANCE RATED C CONDUIT PLC$ PLACES (QUANTITY) CU COPPER CONDUCTOR PNL PANEL COVE CITYOFVEROSEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECTCURRENT RMC RIGID METAL CONDUIT DISC DISCONNECT RTU ROOFTOP UNIT EXIST EXISTING BE SERVICE ENTRANCE RATED FPL FLORIDA POWER 6 LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER US UNDERGROUND IRC INDIAN RIVER COUNTY UL UNDERWRITERS LABORATORY -KVA -- KILOVOLTAMPERE-- - - -----`=UON— "UNLESS OTHERWISE NOTED --- KW KILOWATT V VOLT MC METAL CLAD CABLE VA VOLTAMPERE MCB MAIN CIRCUIT BREAKER W WATT MCC MOTOR CONTROL CENTER XFMR TRANSFORMER MOP MAIN DISTRIBUTION PANELBOARD ELECTRICAL LEGEND: GENERAL NOTES: -� 1. LIGHT LINE WORK REPRESENTS SURFACE MOUNT 12=NV, 10, 3-WIRE PANELBOARD iRllnESQE 9o.B R ZR— R P/.TNG NON -FUSED DISCONNECT 2. DARK AND RED LINE WORK REPRI �,`WNW EQUIPMENT, CONDUIT, AND WIRE FLUSH MOUNT 1201204V, 10, 3-WIRE PANELBOARD , '3R—NM Im FUSED DISCONNECT E�111111_ SURFACE MOUNT 277/48OV, 30, 4WIRE PANELSOARD —Yrn��\s� =Ewiil- FLUSH MOUNT 277I4BOV, 30, 4-WIRE PANELBOARD UTILITY METER CAN OR METER CAWCOMBO UNIT CONDUIT AND WIRE SCHEDUL SYMBOL DESCRIPTION O 2'PVC UNDERGROUND SERVICE FEEDER WI (3) 01) 0 _ UrPVC WI(1)14 BARE CU © 1'PVC W/ (3) 66 THHN CU. (1) OB THNN CU GRI �_ SURFACE MOUNT AUTOMATIC TRANSFER SWITCH V POINTOFNEWCONNECTION CUGROUNDRODSHOLE AT UTILITY POLE SCOPEOFWORK GENERAL NOTES: • INSTALL 100 AMP METER/MAIN COMBO CAN ON B' SQUARE CONCRETE POST. THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION • INSTALL (2)W/ ff GROUND RODS. DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • RUN NEW CONDUIT AND BRANCH CIRCUITS UNDERGROUND TO COLUMN SHOWN • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION(W17), LOCAL ON THE PARTIAL SITE PLAN ON SHEET E2 ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • BRING NEW CONDUITAND BRANCH CIRCUITS UP COLUMN AND RUN ALONG • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED INA NEATAND CRAFTSMAN LIKE MANNER BY STRUCTURAL BEAM TO COLUMN SHOWN THE PARTIAL SITE PLAN ON SHEET E2. PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN BRING CONDUIT BACK DOWN AT PARKING SPACE 99 TO RECEPTACLES MOUNTED LICENSED IN THE STATE OF FLORIDA AT 56' ABOVE FINISHED FLOOR: THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND • PROVIDE AND INSTALL (1) 1450R AND (1) 15-20R RECEPTACLES WITH WEATHER FASTENED, WITH WORKING SPACE PER NEC 110.26. PROOF WHILE IN USE COVER. PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. _ ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 2W. NO SOF ELECTRICAL RISER DIAGRAM STRUCTURAL BEAM (NEW)14SOR AND 15-20R RECEPTACLE AT PARKING SPACE 99 MOUNTED ON BACK SIDE OF COLUMN FACING TOWARDS PARKING SPACE 99. r� LILI GRADE RECEIVED srV VOON FEB 2 8 2018 i ST. Lucie County, Permitting Uci w W F- W Q Lum ILI W Cl) ED rz m � w w U • E1 02114/2018 1 OF2 ABBREVIATIONS: AC ALTERNATING CURRENT MFS MANUALTRANSFFRSWRCH AIC AIRCONDITIONING MLO MAW LUGS ONLY AL ALUMINUM NEC NATIONAL ELECTRICAL WOE AHU AIR HANDLING UNIT NTS NOTTOSCALE ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NONSE NON SERVICE ENTRANCE RATED C CONCUR PLC$ PLACES (QUANTITY) CU COPPERCONDUCTOR PNL PANEL COVE CRYOFVEROSEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECTCURRENT RMC RIGID METAL CONDUIT DISC DISCONNECT RTU ROOFTOPUNIT EXIST EXISTING BE SERVICE ENTRANCE RATED FPL FLORIDA POWERS LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER UG UNDERGROUND IRO INDIAN RIVER COUNTY UL UNDERWRITERS LABORATORY KVA -KILOVOLTAMPERE --'— -UON--UNLESS OTHERWISE NOTED — KW KILOWATT V VOLT MC METAL CLAD CABLE VA VOLTAMPERE MCB MAIN CIRCUIT BREAKER W WATT MCC MOTOR CONTROL CENTER XFMR TRANSFORMER MOP MAIN DISTRIBUTION PANELSOARD CU GRDUND RODS HOLE AT EXISTING UTILITY POLE SCOPE OF WORK: • INSTALL 100 AMP METERIMAIN COMBO CAN ON 6' SQUARE CONCRETE POST. • INSTALL(2) SMXB' GROUND RODS. • RUN NEW CONDUIT AND BRANCH CIRCUITS UNDERGROUND TO COLUMN SHOWN ON THE PARTIAL SITE PLAN ON SHEET E2. • BRING NEW CONDUIT AND BRANCH CIRCUITS UP COLUMN AND RUN ALONG STRUCTURAL BEAM TO COLUMN SHOWN THE PARTIAL SITE PLAN ON SHEET E2. BRING CONDUIT BACK DOWN AT PARKING SPACE N TO RECEPTACLES MOUNTED AT 56' ABOVE FINISHED FLOOR • PROVIDE AND INSTALL (1)/4-BOR AND(1) I&MR RECEPTACLES WITH WEATHER PROOF WHILE IN USE COVER. ELECTRICAL LEGEND SURFACE MOUNT 12W204V, 10, 3-WIRE PANELBOARD FLUSH MOUNT 12WG4V, 10, 3-WIRE PANELBOARD —�— SURFACE MOUNT2777480V, 30, 4-WIRE PANELBOARD �= FLUSH MOUNT 2771480V, 30,4-WIRE PANELBOARD UTILITY METER CAN OR METER CANICOMBO UNIT SURFACE MOUNT AUTOMATIC TRANSFER SWITCH POINT OF NEW CONNECTION GENERAL NOTES: 1. LIGHTLINEWORK REPRESENTS EXISTINGTO Duxes st—NFeeA w.iwc NON -FUSED DISCONNECT 2. DARK AND REDLINE WORK REPRESENT NEW EQUIPMENT. `uox ruses EOUIPMEM. CONDUIT, AND WIRE. FusSDDlscoxNEcr ruses • CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION AO YPVC UNDERGROUND SERVICE FEEDER WI(3)A110 THWN AL ® UWPVC WI (1)94 BARE CU © YPVC W1(3) 06 THHN CU.(1) 68 THHN CU GROUND GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION(2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 11026. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NECARTICLE 250. NO S ELECTRICAL RISER DIAGRAM Ae a3NNbog STRUCTURAL BEAM (NEW)14SOR AND 15.20R RECEPTACLE AT PARKING SPACE 99 MOUNTED ON BACK SIDE OF COLUMN FACING TOWARDS PARKING SPACE 99. 56' GRACE K sT.LucjECOluvfTy PW �r PlT1M6=1 pyECM:� N USN. Z LU I—w9 m LU m N uJrr J T � a V CO 0 ° co ul J�C W LO 6 Y� O ,�a Q--W E1 02114/2018 I. I OF ABBREVIATIONS: - AC ALTERNATING CURRENT NITS MANUALTRANSFERSWITCH AID AIR CONDITIONING MUD MAIN LUGS ONLY AL ALUMINUM NEC NATIONAL ELECTRICAL CODE AHU AIR HANDLING UNIT NTS NOT TO SCALE ATE AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NON -SE NON SERVICE ENTRANCE RATED C CONDUIT PLCS PLACES (QUANTITY) CU ' COPPER CONDUCTOR PNL PANEL COVB CIIYOFVEROBEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECTCURRENT RMC RIGID METAL CONDUIT DISC DISCONNECT RTU ROOF TOP UNIT EXIST EXISTING BE SERVICE ENTRANCE RATED FPL FLORIDA POWER& LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER UG UNDERGROUND IRC INDIAN RIVER COUNTY UL UNDERWRITERS LABORATORY KVA---KILOVOLTAMPERE - --i- LION ----UNLESS OTHERWISE NOTED — KIN KILOWATT V VOLT MC METALCLADCABLE VA VOLT AMPERE MCS MAIN CIRCUIT BREAKER W WATT MCC MOTORCONTROLCENTER XFMR TRANSFORMER MDP MAIN DISTRIBUTION PANELBOARD CU GROUND RODS HOLEAT EXISTING UTILITY POLE SCOPE OF WORK: • INSTALL 100 AMP METER/MAIN COMBO CAN ON 6' SQUARE CONCRETE POST. • INSTALL (2) M'X$' GROUND RODS - RUN NEW CONDUIT AND BRANCH CIRCUITS UNDERGROUND TO COLUMN SHOWN ON THE PARTIAL SITE PLAN ON SHEET E2. • BRING NEW CONDUITAND BRANCH CIRCUITS UP COLUMN AND RUN ALONG STRUCTURAL BEAM TO COLUMN SHOWN THE PARTIAL SITE PLAN ON SHEET U. BRING CONDUIT BACK DOWN AT PARKING SPACE 99 TO RECEPTACLES MOUNTED AT 56' ABOVE FINISHED FLOOR. • PROVIDE AND INSTALL(1)14-50R AND 15-20R RECEPTACLES WITH WEATHER PROOF WHILE IN USE COVER. ELECTRICAL LEGEND: GENERAL NOTES: 1. LIGHTLINEWORK REPRESENTS EXISTINGTO SURFACE MOUNT 120204V, 10, 3-WIRE PANELBOARD�� RwnssRF n) � m— Nou nAm+c NON -FUSED DISCONNECT 2 DARK AND RED LINE WORK REPRESENT NEW FLUSH MOUNT 1202D4V, 10, 3-WIRE PANELBOARD �NONFusm EQUIPMENT, CONDUIT. AND WIRE. CONDUIT AND WIRE SCHEDULE —�— SURFACE MOUNT 2T7MBOV, 30, 4-WIRE PANELBOARD 1 a>a NDMBAT FUSED DISCONNECT � MSES= SYMBOL DESCRIPTION FLUSH MOUNT 277/480V, 30,4-WIRE PANELBOARD OA 2•PVC UNDERGROUND SERVICE FEEDER W/(3)MM MINN AL _ ® IWPVCW/("BARECU UTILITY METER CAN OR METER CAWCOMBO UNIT © 1-PVC WI(3) 66 THHN CU.(1) 98 THNN CU GROUND C� SURFACE MOUNT AUTOMATIC TRANSFER SWITCH — POINTOFNEWCONNECTION Alunoo11eionl ,4 a3NNH'Sg GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION(2017), LOCAL. ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 11026. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUTI' SNALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 250. NO$ ATE ELECTRICAL RISER DIAGRAM STRUCTURAL BEAM (NEW)1450R AND 15Q0R RECEFTACLEATPARKING SPACE BB MOUNTED ON BACK SIDE OF COLUMN FACING TOWARDS PARKING SPACE 0. 56' GRADE ST.L, poIscoUfc1N P B1DG��� DATE: `i DAr �5:a�4 PWlAB:� MECH:� IS I WZ Of W VI J � J z U_QQ D'Wp rr J Z W E1 „i.0211412018 10F2