HomeMy WebLinkAboutPROJECT INFORMATIONBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPON TITS A CLADDING (&SF.) FOR ASCE 7-f0 - P AK ROOF HEIGHT LESS THAN OR EauAL rn 6o FEET *' BASIC WIND SPEED = 170 mph RISK CATEGORY R BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 7'-9" L" GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" L" GREATER OR EQUAL THAN 12'-3' HEIGHT PQS/AYE NEGATIVE PoSmVE NEGAnYE POSITIVE NEGATIVE --(h) -OLAMATE_ _AS.D.__ULAWTE__A.SD._ ULTIMATE__ A_SD_- _UL7 uyA _-ASD. ULTIMATE ASD. ULTIMATE ASD. o' - 15, 76.4 45.8 1 102.4 67.4 73.0 43.8 95.5 5Z3 68.5 1 41.1 86.4 51.8 > 15'-20' 80.4 46.2 1076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 1. 79.8 4Z9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69 1 82.4 49.4 7077 64.6 773 46.4 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 1 75.7 1 90.0 54.0 11Z7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 8Z2 52.3 709.9 65.9 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM&LIAWCE MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSIVAE FOR COMPONENTS & cLADDING (P S FF,) FOR ASCE 7 /0 PEATY ROOF H EGHT GMTER THAN an FEET* BASIC WIND SPEED = 170 mph RISK CATEGORY If BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) u to RE C CEIVED ONCEALED CA MAR 0 2 2018 L Lucie County, Permitting PEAK ROOF I' LESS THAN 12-3" 1' GREATER OR EQUAL THAN 12'-3' HEIGHT POS 1VE NEGATNE PoSIT/VE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE I A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 1030 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' -100' 973 58.4 778.4 1074 89.7 538 1579 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 40' 103.2 789.2 95.1 571 1674 100.4 1aD' - 16o f05. 63.4 193.6 716.2 97.3 58.4 171.3 102.8 > 160' - t80, 107E 64.7 1976 1 f .6 99.3 59.6 174.9 104-9 > 180' - 200' 109.8 65.9 201.3 120.8 101. 1 60.7 178.1 106.9 > 200' - 250' 1 14. 1 68.5 209.2 125.5 f 05.2 63. 1 185.1 11 1. 1 > 250' - 30O' 117.8 70. 1 216.0 129.6 108.5 65. 1 791.1 114.7 > 300' - 350' 121.0 72.6 221.9 133. 1 1 f 1.5 66.9 796.3 717.E > 350' - 400' 123.9 74.3 22Z I f36.3 114.7 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 128.8 1 77.3 1 236.1 141.7 1 118.6 1 71.2 208.9 1 125.3 NO 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE 1NFORM4AON FOR A SITE SPECIFIC PROJECT 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES, 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMN HOLDER FROM THIS WIND LOAD CHART SHALL BE /ND/C47ED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.9., SPREADSHEET, OPENING SCHEDULE/7AKE OFF SHEET, ETC.). IENEHS OR A11ACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 1I+� o p. II((��'r�� . ,,C...S, N0.44167 S 'o t s7sim OF = G. ZONE AND INTERIOR ZONE COA AND FOR ALL ROOF SLOPES. * L - STORM PANEL LENGTH, ACCORDION SHUTTER BLAO£ LENGTH OR RANAMA SHUTTER HEIGHT. PRODUCTS WHICH BEAR A M/AMI-DARE COUNTY OR A STATE OF FLORIDA APPROVAL PI ito �E�rp, 2017 (6th EDMON) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & IND14N RIVER COUNTIES ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & B4HW SHUTTERS **x DRAWN BY RISK CAT. Il SLOGS 08109117 L E C C I m o, WIND PRESSURE CHART DATE JT TESTING & ENGINEERlh CQYPANY BASIC WIND SPEED - 170 mph MW. l6M. 81 S MS. NR " GIRUDVS R, M166 EXPOSURE D. Kd = 0.85 17- 194 I-.: (3GHIJI-Ism. F.: (m9)871-I6Jf DRAWING No EB-0006719 '¢' �' wrz ay. Im uzavm8 arz WALTER A TILLIT Jr. P.E. I aIe Is -Tee FLORIDA Uc. B 44167 . /I SHEET I OF I