MIAMI-DADE COUNTY
i
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786)315-2599
NOTICE OF ACCEPTANCE(NO A www.miarnidadc.eov/economy
Owens Corning
One Owens CorningParkway
Toledo, OH 43659 MAR 0 2 2018
SCOPE: ST. Lucie County, Permitting
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: WeatherlocO Specialty Tile & Metal Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 13-1010.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0522.01
Expiration Date: of
Approval Date: 07/27/17
FILV-1 Py
Pagee I of 4
ROOFING COMPONENT APPROVAL
Category:
Sub -Category:
Material:
Roofing
Underlayment
SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions Specification
Description
Weatherlock® 36" x 33.3'
rolls TAS 103
SBS self -adhering asphalt sheet material with a
Specialty Tile & 36" x 66.7'
rolls ASTM D 1970
white or green glass re -enforced polyester
Metal Underlayment
surfacing fabric; for use as an underlayment in
sloped roof assemblies.
MANUFACTURIGN LOCATION:
1. Brentwood, NH.
2. Houston, TX.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
R14610
Follow up Service
03/28/02
IRT-Arcon, Inc.
02-012
TAS 103
02/28/02
PRI Asphalt Technologies, Inc.
NEI-006-02-01
TAS 103
04/01/02
NEI-008-02-01
TAS 114 (H)
07/30/02
PRI Construction Materials
NEI-045-02-01 ASTM
D 4798 & ASTM G 155
08/08/07
Technologies, LLC.
NEI-053-02-01 ASTM
D 4798 & ASTM G 155
05/01/08
NEI-076-02-01
TAS 103 / ASTM D4798
02/14/11
NEI-034-02-02
ASTM D 1970
10/28/13
OCF-312-02-01
ASTM D 1623
07/03/17
OCF-320-02-01
TAS 103
06/28/17
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1:
Wood, non -insulated, new construction
Deck Description:
15/32" or greater plywood or wood plank
System E(1):
Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane:
One or more plies of Weatherlock® Specialty Tile & Metal Underlayment with a minimum 3"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the roof with Weatherlock® Specialty Tile & Metal Underlayment
is acceptable.
Surfacing:
Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof
Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
LINUTATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. Weatherlock® Specialty Tile & Metal underlayment shall be installed in strict
compliance with applicable Building Code.
3. Weatherlock® Specialty Tile & Metal underlayment shall be applied to a smooth, clean and dry surface with deck
free of irregularities.
4. Weatherlock® Specialty Tile & Metal underlayment shall not be applied over an existing roof membrane as a
recover, but may be applied over roofing Base/Anchor sheet underlayment.
5. Weatherlock® Specialty Tile & Metal underlayment shall not be left exposed as a temporary roof for longer than
90 days of application.
6. The standard maximum roof pitch for Weatherlock® Specialty Tile & Metal underlayment shall be 6:12 when tiles
are loaded directly to the Weatherlock® Specialty Tile & Metal underlayment; loading boards of battens are
required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. Weatherlock® Specialty Tile & Metal underlayment may be used with any approved roof covering Notice of
Acceptance listing Weatherlock® Specialty Tile & Metal underlayment as a component part of an assembly in the
Notice of Acceptance. If Weatherlock® Specialty Tile & Metal underlayment is not listed, a request may be made
to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty
Tile & Metal underlayment shall be applied over the underlayment.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
-----Rule_6iG20_3_of-the_Florida_Administratiy_e_Code:--
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below.
END OF THIS ACCEPTANCE
NOA No.: 17-0522.01
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 4 of 4
MI®�MIAND-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DMSION Miami, Florida 33175-2474
RECEIVED T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANC OA www.miamidade.eov/economv
Petersen Aluminum Corporation
102 Northpoint Parkway, Bldg.10 a. Lucie County, permltung
Acworth, GA. 30102
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 5-V-Crimp 24 ga. Steel (min) over'/2" (min) plywood
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
---INSPECTION: - A copy of this entire NOA shall be -provided -to the user -by the manufacturer -or. its -distributors -_and -
shall 6e availablefor inpe sction at the job site at the request of the Building Official.
This NOA consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino IN
APPROVED
NOA No.: 17-1002.17
Expiration Date: 11/09/22
Approval Date: 11/09/17
Page I of 5
ROOFING SYSTEM APPROVAL:
Category
Roofing
Sub -Category:
Metal, Panels (Non -Structural)
Material:
Steel
Deck Type:
Wood
Maximum Design Pressure: -176 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions Specifications
Description
24 ga. Steel L = varies' TAS 110
24 ga. (min.) Steel, galvanized or galvalume,
5-V-Crimp Metal W = 20.5"-24"
preformed metal panels, painted or unpainted.
Roof Panel H = %a"
Min. Thickness 24 ga.
Min Yield Strength: 58 ksi.
Fasteners #10 HWH of sufficient TAS 110
Coated steel or stainless steel screw with
length to penetrate through
capped hex head bonded washer.
sheathing a minimum of 3/16"
Trim Pieces L = varies TAS 110
Standard flashing and trim pieces.
W = varies
Manufactured for each panel width.
Min. Thickness 24 ga.
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Test Name/Report Date
Architectural Testing, Inc. D9330.01-450-18
TAS 100 10/13/14
D9330.02-450-18
TAS 125 10/13/14
Valspar
Valspar
433X515 ASTM B 117 11/21/11
433B173 ASTM D 4587, ASTM G 23 11/21/11
NOA No.: 17-1002.17
Expiration Date: 11/09/22
Approval Date: 11/09/17
Page 2 of 5
APPROVED ASSEMBLIES:
System A: 24 ga. Steel S-V-Crimp Metal Roof Panel —
HORIZONTAL LAPS ARE PERMITTED
Deck Type: Wood, Non -insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood.
Maximum Uplift See Table A below.
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than "/32" thick (Minimum
15/32") the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1 ''/d' annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
,the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with PAC Contractors Association's current published installation instructions.
Metal Panels and Install the "24 ga. Steel S-V-Crimp Metal Roof Panels" and accessories in compliance with
Accessories: PAC Contractors Association's current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed in
compliance with the minimum requirements provided in Roofing Application Standards RAS
133.
Panels shall be fastened with corrosion resistant #10 HWH screws of sufficient length to
penetrate through the sheathing a minimum of 3/16". Fasteners shall be installed parallel to the
roof slope along the panel's overlapping ribs (fastening of the center rib is optional) at a
maximum spacing as listed in Table A below.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressure
-82.25 psf.
-176 psf.
-Maximum-Fastener S acin----.--_
—161'—o.c.
—-8"—o.a— ---
1. Extrapolation shall not be allowed
NOA No.: 17-1002.17
Expiration Date: 11/09/22
Approval Date: 11/09/17
Page 3 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended comers and corners).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133. HORIZONTAL LAPS ARE PERMITTED
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the
manufacturer's name and/or logo, and/or model.
tN1AWDADE COUNTY
,E 1
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine models # 6272, 6407 or 6738 from PAC Contractors
Association or manufactured at Petersen Aluminum Corporation's plant in Acworth, GA.
NOA No.: 17-1002.17
Expiration Date: 11/09/22
Approval Date: 11/09/17
Page 4 of 5
PROFILE DRAWINGS
STIFFENING RIBS AND/OR STRIATIONS ARE OPTIONAL
■
DESCRIPTIONGENERAL PANEL
PANEL MATERIAL
Steel & Aluminum
MIN. PANEL THICKNESS
24ga &.032' Aluminum
PANEL WIDTH
20.5" to 24.0" Coverage
PANEL RIB HEIGHT
3B' Minimum
LWL StHerdrg Rihsa Pend Shia6 am ophorud
PANEL. FASTENERS:
Ala Hex Head rNood So -s
w Father Sealing%Vashars
r
v acsthatic purpuscs, fastcnos
Bra contci rib arc optional
PAC CONTRACTORS
ASSOCAATiaN
END OF THIS ACCEPTANCE
NOA No.: 17-1002.17
Expiration Date: 11/09/22
Approval Date: 11/09/17
Page 5 of 5