Loading...
HomeMy WebLinkAboutMISC LETTERc� h PAUL WELCH INC. medh9 ical * Elmdeal * Civil Erlgiridetiv 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone ,(772) 785 - 9888. Email pwelchinc@aol.com March 6, 2018 Re: Belliveau Shutter Installation 9650 S. Ocean Dr. (91101) Jensen Beach, FL 94957 To Whom It May Concern: SCANNED BY 'T I-U�IE COUNTY Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. Wi6d speed Votr: 1,65 mph, Vad: 129 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch and Sliding Doors (See Attached Sketch) Required Design Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Rorida Product Apprbvaf and*orida $tuning code ton. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. —Submitted:by:-- --- — -- PA WELCH INC. I Paul Welch,-P.E. Reg: No_29945 FILE COPY J