HomeMy WebLinkAboutMISC LETTERl
PAUL WELCH INC.
iGMWhWlicAt *- Electrical' * CivitEngiiteernrg
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone.(772}785-- 9A&
Email pwelchinc@aol.com
March.6, 20.18.
Re: Sampson Shutter-Iastallation
8750 S. Ocean Dr. PH-42
Jensen Beach,`FL 34957
To Whom It May Concern:
SCANNED
BY
ST LUCIE COUNTY
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code 2011 for the installation of accordion shutters at the above
referenced address.
Wind speed Vox: 165 mph, Vasd: 128 mph
Exposure: D
Enclosure Type: Enclosed
Shutter Size: 96" Maximum Height
Shutter Location: Covered Porch (See Attached Sketch)
Required Design Pressure: +51.3 / -68.7 PSF
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure".
Accordion Shutters shall be installed in accordance with the shutter manufacturer's
iristallatioii instructiotis and Florida Product Approval Arid Florida Building Lodi= 2017.
Accordion Shutters shall be FL# 389.1.
Thank you for your attention to this matter.
--_ - ---Submitted:by
PAULIWELCH INC.