Loading...
HomeMy WebLinkAboutMISC LETTERl PAUL WELCH INC. iGMWhWlicAt *- Electrical' * CivitEngiiteernrg 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone.(772}785-- 9A& Email pwelchinc@aol.com March.6, 20.18. Re: Sampson Shutter-Iastallation 8750 S. Ocean Dr. PH-42 Jensen Beach,`FL 34957 To Whom It May Concern: SCANNED BY ST LUCIE COUNTY Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2011 for the installation of accordion shutters at the above referenced address. Wind speed Vox: 165 mph, Vasd: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's iristallatioii instructiotis and Florida Product Approval Arid Florida Building Lodi= 2017. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. --_ - ---Submitted:by PAULIWELCH INC.