HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC.
Mechanical * Electrical * Civil Eugiueering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772� 785. - 9888
Email pwelchinc@aol.com
March 6, 2018
Re: Pirrone Shutter Installation
9900 S. Ocean Dr. (#1404)
Jensen Beach, FL 34957
To Whom It May Concern:
SCANNED
BY
ST LUCIE COUNT\,
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code 2017 for the installation of accordion shutters at the above
referenced address.
Wind speed: Uatt: 165 mph, U.,a: 1.28, mph.
Exposure: D
Enclosure Type: Enclosed
Shutter Size: 96" Maximum Height
Shutter Location: Covered Porch (See Attached Sketch)
Required Design Pressure: +51.3 / -68.7 PSF
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure".
Accordion Shutters shall be installed in accordance with the shutter manufacturer's.
mstallatim instrudti6its and Florida Pr6dudt Approval and Florida $uilding Code 2017.
Accordion Shutters shall be FL# 389.1.
Thank you for your attention to this matter.
PAUI WELCH INC. -
Paul Weich, P.E.
Reg. No 29945