Loading...
HomeMy WebLinkAboutMISC LETTERPAUL WELCH INC. Mechanical * Electrical * Civil Eugiueering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772� 785. - 9888 Email pwelchinc@aol.com March 6, 2018 Re: Pirrone Shutter Installation 9900 S. Ocean Dr. (#1404) Jensen Beach, FL 34957 To Whom It May Concern: SCANNED BY ST LUCIE COUNT\, Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2017 for the installation of accordion shutters at the above referenced address. Wind speed: Uatt: 165 mph, U.,a: 1.28, mph. Exposure: D Enclosure Type: Enclosed Shutter Size: 96" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +51.3 / -68.7 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's. mstallatim instrudti6its and Florida Pr6dudt Approval and Florida $uilding Code 2017. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. PAUI WELCH INC. - Paul Weich, P.E. Reg. No 29945