Loading...
HomeMy WebLinkAboutNOASCANNED BY MIAMI•DADE ST LUCIE COUNTY 0 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) _ BOARD AND CODE ADMINISTRATION DIVISION MIAMi-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 T (786) 315-2590 F (786) 315-2599 w v.miamidade.sov/economy EGS International, LLC COP d 3133 S.W. 25� Street Pembroke Park, FL 33009 LE .SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. T he documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of theapplicablebuilding code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION-- Atlantic Series Aluminum Sliding Glass Door — SALI. APPROVAL DOCUMENT: Drawing No. W04-80 Rev I, titled "Atlantic Series SM 130 Alum Sliding Glass Door", sheets 1 through 8 of 8, prepared by AL-Farooq Corporation, dated 09/10/04 and last revised on DEC 07, 2017, signed and sealed by Javad Ahmad, P-E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Small Missile Impact Resistant Limitations: 1. See Design Pressure (DP) ratings with glass types & Reinforcing in sheet 2. See DP ratings of anchor types in sheet 3. Lower Design Pressure Ratings shall apply to entire system. Positive (Exterior) DP shall be limited to sill height per sheet 2. 2. The total tested frame area must not exceed 180 sq. ft. per FBC requirements_ 3. All SGD doors containing operable panel (X) require channel reinforcement (item #3I) at Bottom Rails. LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered afr--r a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMIIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. &Iisuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA_ Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by .the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. 1NSPECTION: A -copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 914-0807.18 and consists of this page'I and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitteddocumentation was reviewed by Ishaq L Chanda, P.E. NOA No.17-1218.21 Expiration Date. December 24, 2019 Approval Date: February15, 2018 Page 1 .i EGS International LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Manufacturer's die drawings and sections.(Submitted underNOA# 12-0131.14, 09-0520.07) 2. Drawing No. W04-80 Rev H, titled "Atlantic Series SM 130 Alum Sliding Glass Door", sheets 1 through 8 of 8, prepared by AL-Farooq Corporation, dated 09/10/04 and last revised on 12/18114, signed and sealed by Javad Ahmad, P.E. B. TESTS (submitted under files# 12-0131.15/#09-0520.08) 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Smal Missile Impact Test per FBC, TAS 201-94 4) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5728, dated 10/10/08, signed and sealed by Carlos Rionda, P.E. (Subuddded under NOA# 09-0520.07) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 241132-1, TAS 202-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4183, dated 05/18/04, signed and sealed by Edmundo Largespada, P. E. along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-2652, dated 05/15/00, signed and sealed by Aldo P. Gonzales, P.E. 3. Additional referenced report FTL 1622, per SFBC, PA 201, 202 &203-94, prepared by Fenestration Testing Laboratory, Inc., signed and sealed by Late Gilbert Diamond, P.E., along with addendum letter dated 05/01/98, issued by Fenestration Testing lab. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014, 5'h Edition, prepared by Al Farooq Corporation, dated 07/23/14 and revised on DEC 03, 2014, signed and sealed by Javad Ahmad, P-E. 2. Glazing complies with ASTM E1300-02 & -04. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. ivLATERIAL CERTIFICATIONS --I-. -. —Notice o Acce tance•No-12=1231:08Tssued'Eas�ChemicaI-Coin an - former P P -Y�) �=�-- Solutia Inc. for "Saflex CP TM - Saflex and Saflex HP Composite Glass Interlayer w/ PET Core", expiring on December 11, 2018. )sl ^g 1. (1,4"J, shaq I. Chands, P.E. Product Control Examiner NOA No.17-1218.21 Expiration Date: December 24, 2019 Approval Date: February 15, 2018 E-1 EGS International. LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 2014, 5w Edition and letter of no financial interest, prepared by Al Farooq Corporation, dated 07/04/14, signed and sealed by Javad Abroad, P.E. 2. Laboratory compliance as part of the above referenced test report. G. OTHERS 1. This NOA revises & renews NOA #12-0131.15 expiring on December 30, 2014. 2. New Evidence submitted. A. DRAWRiGS 1. Drawing No. W04-80 Rev I, titled "Atlantic Series SM 130 Alum Sliding Glass Door", sheets 1 through 8 of 8, prepared by AL-Farooq Corporation, dated 09/10/04 and last revised on DEC 07, 2017, signed and sealed by Javad Ahmad, P.E. Note: This revision consist of editorial changes of FBC 17 (6th Edition) code compliance. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0423.16 issued Eastman Chemical Company (MA) former SoIutia Inc. for "Saflex HP Clear and color Glass", expiring on April 04, 2018. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (61 Edition), dated 11/14/17, prepared by Al Farooq Corporation, signed and sealed by Javad Ahmad, P.E. H. OTHER 1. This NOA revises # 14-0807.18, expiring 12/24/19. 1shaq L Chanda P.E. Product Control Examiner NOA No. 17-1218.21 Expiration Date: December 24, 2019 Approval Date: February15, 2018 E-2