Loading...
HomeMy WebLinkAboutNOAMI®DARE MIAMI—DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/economy WinDoor,.Incorporated SCANNED 7500 Amsterdam drive BY Orlando, Florida, 32832 St. Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER— Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "8100" Aluminum Sliding Glass Door W/WO Reinforcements-S.M.I. APPROVAL DOCUMENT: Drawing No. 08-00878, titled "8100 Series SMI: Reinforced & Non - reinforced", sheets 1 through 27 of 27, including sheets SA, 6A, 7A, 14A, 18A, 20A, 21A, 22A, prepared by manufacturer, dated 12/03/09 with Revision D dated 11/30/17, signed and sealed by Luis R. Lomas, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Small Missile Impact Resistant LEmaTATION: 1. 3-1/2" sill riser item # 36(sheets 1 thru 7A) is limited to positive (exterior) Dp =+100 PSF, item #37 (4- 1/2") sill riser to be used above +100 psf. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/ series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. 199PECTION: A- copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA-revises NOA # 15-0723.10 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P. E. 9%111111111NOA No.17-1219.07 MIAMIAA®UN7r 0' �' /'�1 Expiration Date: March 31, 2021 ai r G Approval Date: July 26, 2018 .rM l fir• '" .� WinDoor. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0209.13) 2. Drawing No. 08-00878, titled "8100 Series SMI: Reinforced & Non -reinforced", sheets I through 27 of 27, including sheets 5A, 6A, 7A, 14A, 18A, 20A, 21A, 22A, prepared by manufacturer, dated 12/03/09 with Revision C dated 06/15/15, signed and sealed by Luis R. Lomas, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with marked -up drawings and installation diagram of Aluminum Sliding Glass, prepared by National Certified Testing Laboratories Inc, Test Report No. NCTL-210-3573-3 dated 07/31/09 and revised and reissued on 12/16/10 and NCTL-210-3573-4 dated 07/30/09 and revised and reissued on 12/16/10, both signed & sealed by Gerald J, Ferrara, P.E. (Note: This test reports have addendum letters dated 08/03/10 &11/29/10, issued by National Certified Testing Laboratories Inc., signed & sealed by Gerald J, Ferrara, P.E. (Submitted under NOA No. 10-0209.13) C. CALCULATIONS 1. Anchor verification calculations complying w/ FBC-2014, dated 07/14/15 and last revised on 03/09/16, prepared, signed and sealed by Luis R. Lomas, P.E. 2. Glazing complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc., for "Kuraray Butacite ® PVB", expiring on 12/11/2016. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for "Saflex CP — Saflex and Saflex HP Composite Glass Interlayer w/ PET co expiring on 11/11/2018. ifang Zhao, P.E. Product Control Examinor NOA No. 17-1219.07 Expiration Date: March 31, 2021 Approval Date: July 26, 2018 E-1 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC-2014, 5th edition, issued, prepared, signed, sealed and dated 06/08/15 by Luis R. Lomas, P. E. 2. Statement letter of no financial interest, issued, prepared, signed, sealed and dated 06/08/15 by Luis R. Lomas, P.E. 3. Laboratory compliance statement, as part of above referenced test report. G. OTHERS 1. Notice of Acceptance No. 12-0130.14, issued to Continental Glass Systems, Inc. for their Series "8100" Aluminum Sliding Glass Door w/wo Reinforcements-S.M.I., approved on 04/09/12 and expiring on 03/31/16. 2. Test Proposal #08-095513 (consolidated) dated 01/15/09, approved by BCCO. (Submitted under NOA No.10-0209.13) 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 08-00878, titled "8100 Series SMI: Reinforced & Non -reinforced", sheets 1 through 27 of 27, including sheets 5A, 6A, 7A, 14A, 18A, 20A, 21A, 22A, prepared by manufacturer, dated 12/03/09 with Revision D dated 11/30/17, signed and sealed by Luis R. Lomas, P.E. B. TESTS 1. None C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. NOA No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. NOA No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol@ Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/19. 3. NOA No. 17-0712.03 issued to Eastman Chemical Company (MA) for "Saflex CP — Saflex and Saflex HP Composite Glass Interlayer wL PET core"_(formerly Vanceva ,, expiring on-1=1711/2018. - `- -- Sifang Zhao, P.E. Product Control Examinor NOA No. 17-1219.07 Expiration Dale: March 31, 2021 Approval Date: July 26, 2018 E-2 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC 61h Edition (2017), and of no financial interest, dated November 30, 2017, issued, signed and sealed by Luis R. Lomas, P.E. G. OTHERS 1. Notice of Acceptance No. 15-0723.10, issued to WinDoor, Inc. for their Series "8100" Aluminum Sliding Glass Door w/wo Reinforcements-S.M.I., approved on 04/07/16 and expiring on 03/31/21. Sifang Zhao, P.E. Product Control Examiner NOA No.17-1219.09 Expiration Date: March 31, 2021 Approval Date: July 26, 2018 E-3