HomeMy WebLinkAboutPRODUCT APPROVAL414/2019 _ , , _ Florida Building Code Online
aCIS Home ( Log In ,€ Jser Reglstratlon I Hot Topics i submit surcharge Stxts a Facts Publications E contact Us .i ac65ite Map Links Search
�W
`_?' Product Approval
Y}` jf,... USER: Public User
A.fiY.R.'ti+�5E4T
Product ARorovai Menu > ProdW or Application Search > Agorcation Li sf > Application Detail
as
FL #
FL389-R9
M_
Application Type
Revision SCANNED
Code Version
2017 BY
Application Status
Approved St. Lucie County
Comments
Archived
%?
- Product Manufacturer
American Shutter Systems Association, Inc.
Address/Phone/Email
4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
w `
I O
Authorized Signature
Bill Feeley
lrodriguez@easternmetal.com
REVIEWED FOR
Technical Representative
CODE
Address/Phone/Email
e CCOMPLIANCE
Si• LUCIE COUNTY
Quality Assurance Representative
Address/Phone/Email
BOCCL,%
Category
Shutters
Subcategory
Accordion
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
E.1 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A.. Tillit, Jr. P.E.
Evaluation Report
Florida License
PE-44167
Quality Assurance Entity
National Accreditation and Management Institute
Quality Assurance Contract Expiration Date
12/31/2019
Validated By
John Henry Kampmann Jr.
+° Validation Checklist - Hardcopy Received
Certificate of Independence
FL389 R9 COI AMERICAN SHUTTER SYSTEM ASSOC. INC DRAWING 17-
107 CERTIFICATE OF INDEPENDENCE.PDF
FL389 R9 COI AMERICAN SHUTTER SYSTEMS ASSOC'F INC. DRAWING
___
—_17-106=CERTIFICATION20FINDEPENDENCEE(i')iPDF.
FL389 R9 COI AMERICAN SHUTTER SYSTEMS DRAWING 17-108
CERTIFICATE OF INDEPENDENCE.PDF
.. v
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Standard
ASTM E-16
ASTM E-199996
i�
Fide Copy
ASTM E-330
"'--'-•-"�'
TAS 201, 202, 203
Year
2005
2005
2002
1994
https:f/floddabuilding.orgtpr/pr_app_d8.aspx?param=wGEVXQvADgvYYHH2vJvx53MwsXdCOtOXQsoPMYK7UC8%3d 113
4/4/2019
Sections from the Code
Florida Building Code Online-, . ,
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of
Method 1 Option D
09/18/2017
10/18/2017
10/19/2017
12/12/2017
FL # I Model, Number or Name I Description
389.1 Bertha HV Accordion Shutter - Blade Extruded aluminum interlocking blades retained by tracks (top
3 - (Non-HVHZ) - Drwg 17-108 i and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large. Missile Level "D".Max span is 12'-3" for 40 psf
positive ASD load and 13'-0" for 35 psf negative ASD load the
HV3 blade w/o window blade,5'-2" for 110 psf ASD load for HV3
blade w/o window blade and 8'-11" for 62 psf, 9'-11"for 55 psf
HV3 blade w/window blade working in unison.Max.span for HV3
blade w/o window blade for installations into Metal Stud walls is
79" for max. ASD pressure rating of +72,-72 and 84" for
+64,-64 psf. See sheet 5 for other spans and ASD pressures.
Installation Instructions
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEMS DRAWING 17-
108 PRODUCT EVALUATION REPORT PDF
Created by Independent Third Party: Yes
389.2 ( Bertha HV Accordion Shutter -Blade 1 Extruded aluminum interlocking blades retained by tracks (top
j Only- (Non-HVHZ)- Drwg 17-107 and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max. Span is 16'-0" for 30 p.s.f
negative ASD load depending on centermates and locking rod
configuration for the HVl blade, 8'-0" for+64, -72 p.s.f. A.S.D.
load for HV blade for Keystone mountings 7'-0" p.s.f. for metals
stud mountings and 8'-0" for 110 p.s.f. for HV1A working in
unison. See sheets 7, 11 and 20 respectively of installation
drawings for other spans and pressures.
389.3 Bertha HV Accordion Shutter-
COMBO- (Non-HVHZ)- Drwg 17-106
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile. Max. 16'-0" span at 30 p.s.f ASD load for
Blade 1 and 18'-0" for Blade 2. See schedules on sheet 12, 25
and 28 respectively
Installation Instructions
FL389 R9 II AMERICAN SHUTTER SYSTEM ASSOC.,
INC. DRAWING 17-107 BERTHA HV ACCORDION SHUTTER
SYSTEM.PDF
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL389 R9 AE AMERICAN SHUTTER SYSTEM ASSOC_
INC. DRAWING 17-107 PRODUCT OF EVALUATION
Independent Third Party: Yes
Extruded aluminum interlocking blades retained by tracks (top
and bottom) for storm protection
Installation Instructions
Verified By: American Test Lab of South Florida Inc.
Created by Independent Third Party: Yes
Evaluation Reports
by Independent Third Party: Yes
Sark Hezi
Contact Us :: 2601 Blair Stone Road, TallahasseeTaTlahassee Fl, 32399Phone: 850-487-1824
The State of Florida is an AA/EEO employee Cho yright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pursuant to section 455.275(1),
Florida statutes, eneRive October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click hh?e .
Product Approval Accepts:
httpsl/floridabuilding.orglprlpr_app_Otl.aspx?param=wGEVXQwtDgvYYHH2vJ"53MwsXdCOtGXQsoPMYK7UC8%3d 213