DESIGN CALCULATIONS
LRECEIVE—D
2018
Permitting
.FOR SCANNED
BY
St. Lucie County
SHELL ® CIRCLE K
WALL -MOUNTED SIGNS
100 Prima Vista Blvd — Port St Lucie
GENERAL NOTES:
1. Design is in accordance with the Florida Building Code 6th Edition (2017)
for use within and outside the High Velocity Hurricane Zone (HVHZ).
2. Wind loads have been calculated per the requirements of ASCE 7-10 as
shown herein.
3. These engineering calculations pertain onlyto the structural integrity of
those systems, components, and/or other construction explicitly
specified herein and/or in accompanying engineering drawings, The
existing host structure (if any) is assumed to be in good condition,
capable of supporting the loaded system, subject to building department
approval. No warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
required or a separate site -specific engineering evaluation
6. Aluminum components in contact with steel or embedded in concrete
shallbeprotected as prescribed in the 2015 Aluminum Design Manual,
Part 1. Steel components in contact with,lbut not encased in, concrete
shall be coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only.
Use of this specification by contractor, et. Al, indemnifies and saves
harmless this engineerfor all costs & damages including legal fees &
apellate fees resulting from deviation from this design.
WsftemhasbeenelectronF
.Digitally signed
ally signed and sealed by
❑uisdan tangleylpE.og a
by Christian
Dlgital Slgoe PrlMed
coples of Nls donmientare
Langley
not considered signed and
sealed and the signasore
Date:
most be yenned on any
elecboniccoples
2018.03.23
ogmsyw�buw.�s.:
wsoaxoi erwnwmumso
12:37:31 -04'00'
Index:
Pg 1 Cover
Pg 2 Wind Loads
Pg 3 Anchor Design
® No. 382
Chios; ialyV6a 1gleV1 V--,f # 67382
EaSy bealSizi,11rL1SWAuth # 31124
1200 N Federal Hwy, 73200 pp®� �✓i
Boca Raton, FL 33432 Easy Seals.com ! N T Pafi6t���111✓✓✓
EasySeals
/SCE 7-10 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs
V =! 160 mph ISasic wind speed
Exposure! G -I
Calculations
a=9.5 3-sec gust speed power law exponent
zg = 900' Nominal ht. of atmos. boundary layer
Gcpi = 0 internal pressure coeff
160 mph - Exp
"C'
WALL -MOUNTED SIGNS
ASD WIND PRESSURES
SIGN
CENTER 1
CORNER
HEIGHT
(Zone 4)
(Zone 5)
15.11
31.2 psf
39.7 psf
20 ft
33.2 psf €
42.2 psf
25 f# -
34.8 psf I
44.2 psf
30 ft
36.1 psf E
6.0 psf
35ft
37.3 psf i
47.5 psf
40 ft
38.4 psf
E
48.8 psf
45 ft
39.3 psf 1
50.1 psf
'SO.ft
40.2 psf
51.2 psf
55 ft
41.0 psf R
52.2 psf
60 ft
41.8 psf ;
53.2 psf
70 ft
35.3 psf €
70.6 psf
80 ft
36.3 psf
72.6 psf
,90 ft ' -
37.2 psf
74.5 psf
100-ft
38.1 psf !
76.1 psf
116 ft
38.8 psf •'-,
77.7 psf
120.ft
39.6 psf s
I
79.1 psf
130 ft
40.2 psf 1
80.5 psf
140'ft=-
-40:9 psf-6=81-7 psf=
150 ftL42.8psf
82.9 psf
175ft.85.7psf
200-ft
L250)
88.l,psf
ft
92.3 psf
CALCULATIONS FOR WALL -MOUNTED SIGNS
ASD Load Combo Coeff:' 0.6
Kd = 0.85 Directionalityfactor
Kzt 1!0 ' Topographicfactor
A =' 10sq ft, Tributary area
It
Y Y
92
a
tJ V
a
u
0.85
47.3
-1.10
-1.40
0.90
50.2
-1.10
-1.40
0.95
52.7
-1.10
-1.40 ,
0.98
54.7
-1,10
-1.40
1.01
56.5
-1.10
-1.40
1.04
58.1
-1.10
-1.40
1.07
59.6
-1.10
-1.40
1.09
60.9
-1.10
-1.40
1.12
62.2
-1.10
-1.40
1.14
63.3
-1.10
-1.40
1.17
65.4
-0.90
-1.80
1.21
67.3
-0.90
-1.80
1.24
69.0
-0.90
-1.80
L27
70.5
-0.90
-1.80
1.29
71.9
-0.90
-1.80
1.32
73.3
-0.90
-1.80
1.34
74.5
-0.90
-1.80
-
1.38
76.8
-0.90
-1.80
_1.42
79.3
-0.90
-1.80
1.46
81.6
-0.90
-1.80
1.53
85.5
-0.90
-1.80
Page 2
.. EdsySeaLS CALCULATIONS FOR WALL -MOUNTED SIGNS
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure: P=n_46.0 _(Psf
Sign type: Cai-inet
Sign size: A=,!._ _ 63.3 jsgft (entire cabinet)
Wall material: Concrete ;if'c=3,000psimin)
Anchor type/size: 3/8" Expansion Anchor
Ref: Powers Power -Bolt, catalog
Min Embedment: 3.5"
Min edge dist: 4.5" Min Spacing: 7"
Anchor tensile capacity: Tcap = 1300.0 lb (per anchor)
Check Anchors for Pullout
Total Reaction: Rt = 2911 lb ... = P*A (entire cabinet)
No. of anchors req'd: n = 2.2 total anchors ... = Rt/cap
Total anchors required: 3 total anchors balanced over cabinet
OK, use min (8) total, spaced evenly.
Page 3