Loading...
HomeMy WebLinkAboutBUILDING SCHEMATICBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F.) FOR ASC 7-10 - PEAK ROOF HEIGHT LESS TMAN OR EQUAL TO 60 F£ET k BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L** LESS THAN 7'-9" 1- GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" L** GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A-S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 1076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 671 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4 974 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 1177 70.6 84.4 50.6 706.5 63.9 > 50'-6o' 973 58.4 130.3 78.2 92.9 55.7 121.5 72.9 872 52.3 109.9 65.9 SCANNED BY St. Lucie County BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET aK BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS CONCEALED FASTENERS OR ATTACHMENTS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD E D 8 rmitting -a7--6 ST. LUCIE COUNTY BUILDING DIVISION FOR REVIEWED BY -PLAN, Amu-rcnmri -- MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE PEAK ROOF L** LESS THAN 12-3" L- GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80, - 9o, 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 9o' - too' 1 97.3 58.4 178.4 107.4 89.7 53.8 157.9 94.7 100.5 60.3 184.2 92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 571 1674 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160' - 160' 1078 64.7 197.6 118.6 99.3 59.6 174.9 164.9 > 18O' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63. 1 185.1 111.1 > 250' - 300' 1178 70.1 1 216.0 129.6 1 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 :> 350' - 400` _123.9- 74.-3- 22771-_736.3 =1-14.-l--_66:5= 200.9--120.5- > 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 773 236.1 141.7 118.6 71.2 249 125.3 NOTESr 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & IXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. J.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WINO LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED IWAUD IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.9., SPREADSHEET, OPEN/NG SCHEDULE/TAKE OFF SHEET, ETC.). INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. * L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAH4MA SHUTTER HEIGHT. *at:k PRODUC75 WHICH BEAR A MOIMI-DAOE COUNTY OR A STATE OF FLORIDA APPROVAL ?0" �0-) Y�0GO 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & BN-[4MA SHUTIERS *** DRAWN BY RISK CET. H BLDGS 08109117 11 L E C WIND PRESSURE CHART DATE JT TESTING & ENGINEERING G'OMPANY BASIC WIND SPEED = 1mph 17- 194 NW. JINN. a. SG. J05. VIRClw 69RDEN$ R ST166 EXPOSURE D, Kd 0. = 0.85 PA d : (J05)8JI-ISJO . ry : (=I)671-?WI DRAWING No EB-0006719 xev. lm oexemrox wrz xn. x" orrmex as WALTER A 77WT Jr. P.E. r 61O r6-16B /1 J FLORIDA Lie. A 44167 1:1 1 1 4 1 SHEET 1 OF 1 ROVE0 " MAR 2 7 'C3 ST. Lucie County, Permitting Ocean Balcony Rich Porante Residence Frogt_Door 0 -11 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILR OF THE CONTRACTOR OF RECORD Balcony 1 2 3