Loading...
HomeMy WebLinkAboutENGINEERINGSpecifications 79 LEA Medium and Low Temp Hybrid" Reach -Ins: RVCC30 & RVZC30' Note: Effective 111/12, all Zero Zone display cases manufactured for shipment within the U.S. meet current DOE, IECC, and CEC energy requirements." Zero Zone Hybrid" is defined and listed as a remote refrigerated display case. PHYSICAL DATA 1- Medium Temp Low Temp Special"r h r r r I h r r 14.1 27.8 41.4 55.1 68.7 27.8 41.4 41.4 55.1 68.7 28.3 55.6 82.9 110.1 137.4 55.6 82.9 82.9 110.1 137.4 =(lbs.)* 24 24 24 24 24 24 24 24 24 24 Weight522 783 1,033 1,343 1,683 783 1,033 1,033 1,343 1,683 'Does not include weight ofcondensing unit Weights include 2erMpeners 111 pp pain WITH CONDENSATE EVAPORATION ELECTRICAL DATA 1, 2, 3, 4, tt Opt Max Pro2l a LP Lighting, Anthony ELM I ELM-HG2 Doors, „ MOCP (amps) 8 20 15 15 15 15 25 25 30 40 40 MCA (amps) e 14.6 8.7 9.6 12.2 14.0 20.3 21.8 24.0 28.0 32.2 ENERGY DATA Daily Energy Use (kWh) 6.7 24 28 25339.9 44.5 548 Rejected Heat Btuh a 950 4 2 3,528 L5,666 6,339 7,793 WITHOUT• a ELECTRICAL DATA ", 3,4,10 Opt Max Pro24 LED LP Lighting, Anthony ELM I ELM-HG2 Doors, MOCP (amps) a 20 15 15 15 15 25 25 30 40 40 MCA (amps) 9 12.5 8.3 8.3 11.2 13.0 16.9 18.4 21.9 27.2 28.7 ENERGY DATA Daily Energy Use (kWh) 6.6 12.6 17.8 21.7 24.3 24.6 35.0 39.2 43.7 53.8 Rejected Heat Btuh a 936 1,790 2,532 3,091 3,456 3,498 4,975 5,580 6,219 7,651 R-404A CHARGE R-404ACharge lbs. a 3.5 5.0 6.1 7.8 5.3 5.9 7.9 7.4 8.6 REFRIGERATION REFRIGERATION A91634 ZZ Condensing No. 9633 9634 9636 9638 9679 9679 9680 9681 9681 Crated Wei ht Ibs. 118 100 100 120 180 180 180 Doors, 180 180 REGULATORY DATA •.t Max Pro24 LEa TDA(TotalDisplay Area) (@.l 12.10 24.19 36.29 48.38 11 60.48 24.19 36.29 36.29 48.38 60.48 CDEC (Calculated Daily Energy 3.50 6.03 1 8.56 11.09 13.62 14.93 L 21.40 21.40 27.87 34.35 Consumption) kwh1day 13 Notes: 1. 1RVCC30 Hybdd (116V) 3-whe seMce; 115VAPH5011IZ; black pourer, white neutral, green ground. 2. 25 door cases, 208V 4-wIm service; 1151208V-1PH-NHZ; red & black power, white neutral, green ground. Budubowt transformeravagable far lowwltage wndNom. 3. Service disconnect is shipped loose, to be installed on condensing wits. 4. Main service disconnect is not provided. 5. Adequate ventilation must be provided to dissipate rejected heat from the top of the unit for proper performance. Clearance of less than 30• above the top of the shroud to the ceiling requires special design considerations. See Zero Zone Hybrid' Installation and Operation Manual for specific details. 6. Refrigerant shame includes combined condensing unit and case charges. 8. MOCP (Mardmum Over-CumenlProtecton) is the madmum circuitbreakersaethatran be usedta property prated the product 9. MCA(Minimum ClrcutAmpadly) is used to calculate the minimum wire size forthe product This is selected all that wires will notoverheat in typical operating conditions and prevent nuisance circuit breaker trips. 10.Zem Zone recommends that admit bmakers¢e should be largerthan the MCA, but smaller than or equal to the MOCP. For ehampie, tithe equipment is listed having an MCAof 36.8 amps and an MOCP of 45 amps, a 40 amp or45 amp draritbreakerwouid be acceptable. 11. Special 3RVZC30 data Is for the 1RVCC30 Remom13RVZC30 Hybdd configuration only. See remote spec sheet for delays an the Special iRVCC30. 12.Standard 3RVZC30 data is still applicable for the stand alone rase. 13. CDEC energy values do not Include a condensate pan heater, pump. or condensing unit, per 10 CFR 431. 14. DOE -Department of Energy, CEC - California Energy Code; IECC- International Energy Conservation Co`i S SCANNED BY St. Lucie County Factory Installed Hybrid' Features: • Refrigeration piping with quick conned couplings and refrigerant charge. • Pre -wired and labeled for easy connection. • Electronic control Includes: time dock, temperature and defrost control, visual and audible temperature alarm, and network communication capability. Field Installed Hybrid' Features: • 20 IW tall aluminum shroud(tront and sides standard, rear optional). Consult factory for other options. case to proper operating r• IRVCC30 1 RVCC3063000202630000003050112 2RVCC30 2RVCC3063000202630000003050112 3RVCC30 3RVCC3063000202630000003050112 4RVCC30 4RVCC3063000202630000003050112 5RVCC30 5RVCC3063000202630000003050112 2RVZC30 2RVZC3063000202610000005040212 3RVZC30 3RVZC3063000202610000005040212 4RVZC30 4RVZC3063000202610000005040212 5RVZC30 5RVZC30630002026100000050 02 2 x4 CSS-80-A 21211E Medium and Low Temp Hybrid" Reach -Ins: RVCC30 & RVZC307 2 162118' 3 9210 4 I 123' 5 15331 —j 212'ADD FOR f- STANDARD END OR INSULATED DIVIDER AIR FLOW CONDENSING CONDENSATE I UNIT PUMP/PAN r-----� 8 4-- -- ; idm CONDENSATE EVAPORATOR S t— LOWER POSITION INCREASES I CASE DEPTH TO 42118'. 4011V 3 I 37118' 2011V SHROUD 13 REFRIGERATION PIPING (INSULATED) &ELECTRIC BOXWPJNG CAN BOTH CASE PASSES BE MOVEDTO GEf BELOW CASE HEIGHT THROUGH 80" ,a, TALL OPENING 8139' 78 &R' / 13WHATCRANNELS 212116 Specifications are subject to change without notice. Case designed to operate in an ambient temperature of 75'F and relative humtddy of 55% or lower. ZeroZone, Inc. 1 110 N Oaloidge Drive I North Praide, WI 53153-9792 Toll Fe: 800-247496 1 Fax: 26292-6450 Zero-Zone.wm sE OLU O� 0 2016 Zero Zone, Inc, Intertek Condensate Removal and Evaporation System Specs OEB PHYSICAL DATA r Pumps - 63-0255 0.80 115 60 11.1' 90 Pumps - 63-0483 0.50 115 60 12.5' 12 Evap Pan 4.17 500 120 60 Both applications hodude an oWet Notes 1. A condensate collection and removal system includes a collection pan, pump, floatswikh, condensate evaporation pan with heater element and connecting tubing. 2. When used on remote cases, a 15 amp dedicated cscuit(oudet( is required for evaporation pan. Pump - 63.0255 'Dimensions for PumpAssem- bly displayed as shipped. 'ULLisled Pump - 63.0483 'Float switch and check valve on pump •ULLlsted 1/12115 Specifications are subject to change Without notice. CSS-71-B ZeroZone, Ina 1 110 N Oakridge Drive I North Prairie, WI 53153-9792 E O L U T ION Toll Free: 80g-247-0496 Fax: 262-392-6450 Zero-Zane.com © 2016 Zero Zone, Inc.