HomeMy WebLinkAboutENGINEERING0 1 L/ ® �LOLM 0
CARL E. THOMPSON, JR. P.E.
Serving the Ind
Phone: (423)781-7336
Email: carl@tesengrs.com
Mailing Address: P.O. Box
Project #: 011317
ustry Since 1984
Fax: (423)781-7337
Website:tesengrs.com
1500, Englewood, TN 37329
DWG #: EB-6963
Family Dollar 3'-0"x3'-0"x10'-0" Fabric Awning - Southeast & Southwest Elevations
Florida Building Code 6t' Ed. (2017) (ASCE 7-10) VULT = 160-mph Structural Calculations
Location: Family Dollar, 3214 Avenue D, Ft. Pierce, FL 34950
for
emlodumtries In c .
Address: 6434 Burnt Poplar Road, Greensboro, NC 27409
Phone:336-668-2791 www.aIlenindustries.com
P.O.# 165322
5-.
No. 36639 : c
0•• STATE OF
X%Fs+' c� OR
February 9, 2018
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
Pi
w'4 Dollar T-ONT-O'k10'-0" Fabric Awning
O'� *To Section Southeast &Southwest Elevations
CARL E. THOMPSON, JR., P.E. Awning Frame 8 Wall Fastener Design
P.O. Box 1500, Englewood, TN 37329 Calc. by Date ChWd by
Phone: (423) 781-7336 Fan: (423) 781-7337 D.J.W. 1 219/201 S 1 C. E.T.
WIND LOAD & FASTENER DESIGN
WIND LOADING (ASCE7-10)
In accordance with ASCE7-10 incorporating Errata No.1 and Errata No. 2
Using the components and cladding design method
Building data
Job R�
Projec.:: 011318
DWG #: EB-6963
Sheet noJrev
2
Date
2/9/2018
*"_ .S HOMPB ��'�.
n.
or 55 9 Lot /
t0 ,L MY ; C
:V% STATE OF �
Tedds calculation version 2020
Type of roof Flat Length of building b=100.00 ft
Width of building d = 85_00 ft Height to eaves H = 22_00 ft
Height of parapet hp = 3_00 ft
Mean height In = 22_00 ft
General wind load requirements
Basic wind speed
V =160.0 mph
Risk category
II
Exponent coef (r26.6-1)
Kd = 0.85
Exposure category (cl.26.7.3)
C
Enclosure class (cl.26.10)
Enclosed buildings
Int pres coef+ve (T26.11-1)
GCpI_p = 0.18
Int pres coef—ve (f26.11-1)
GCp; n =-0_18
Parapet int. press. coef +ve
GCp; pp = LIS
Parapet int. press. coef—ve
GCpi_pp =-0-0_18
Gust effect factor
Gf = 0.85
Topography
Topo factor not significant
Kn = 1.0
Velocity pressure
Velocity pressure coefficient
K, = 0.92
Velocity pressure
qh = 51.0 psf
Velocity pressure at parapet
Velocity pressure coefficient
K, = 0.94
Velocity pressure
qp = 52.4 psf
Peak velocity pressure for internal pressure
Peak velocity pressure — int q; = 51_03 psf Equations used in tables
Net pressure p = qh x [GCP - GCP;] F LE COPY
Parapet net pressure p = qp x [GCP - GCpiy]
Components and cladding pressures - Wall (Figure 30.4-1 and Figure 30.4-2A)
amity Dollar
1-0"x3'-0"xl0'-0"
abric Awning
one a.engrn wram hill. area *Lwcl
(ft) (ft) (ft)
4 4.2 10.0 41.7 0.80
-GCP
Pres (+ve)
(psi)
Pres (-ve)
(ps[)
-0.89
PULr50.1
PULT=-54.7
V
Paso=30.1
PASD=32.8
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
P`
Job R�'
�G Z HOMP�OO�
Dollar 3'-0"x3'-0"x10'-0" Fabric Awning
a y 9
Southeast & Southwest Elevations
Pro ec., 011318
1 .
DWG #: EB-69
0%�����
M69
Section
sheet nolrev.O%
CARL E. THOMPSON, JR., P.E.
Awning Frame & Wall Fastener Design
3
P.O. Box I500, Englewood, TN 37329
Fax:
'Z� q/r8
STATE OF
Cat. 6Y
Date
Chk'tl by
Date
Phone: (423) 781-7336 (423) 781-7337
D J W
2/9/2018
C.E.T.
2/9/2018
0,� . 400
FRAME DESIGN wn11111
Allowable Stress Design Pressure, P,vsD = 0.6 * 54.7 psf = 32.8 psf
Loadine Method — Continuous Beam — Two Unequal Spans — Unirormly Distributed Load
Tributary Width, Width = (2 ft+ 6 in)=30.000 in Distributed Laod, w= Width * PASD = 82.050lbs/ft
Span 1 Length, LI = (2 ft + 5.5 in) = 29.500 in Span 2 Length, L2 = (1 ft + 8.5 in) = 20500 in
Moment at Middle Support, MI = (-1) * ((w * (L2)' + w *(LI)') / (8* (LI + 1-2))) = _586.102 lb —in
Reaction at Top Support, RI = MI / LI + (w * LI) /2 = 80.985 Ibs
Reaction at Bottom Support, R3 = MI / L2 + (w * Lz) /2 = 41.494 Ibs
Reaction at Middle Support, R2 = w * LI + w * L2 — RI — R3 = 219396 lbs
Location of Max Moment Between Span 1 Supports, XI = RI / w=11.844 in
Max Moment Between Span 1 Supports, Mxl = RI * Xl — (w* (XI)2 / 2)= 479.606 lb —in
Location of Max Moment Between Span 2 Supports, X2 = R3 / w = 6.069 in
Max Moment Between Span 2 Supports, M . = R3 * X2 — (w* �z)2 / 2}= 125.905 lb --in
RT 1"X1"XO.125" WALL Calculation of section properties
77
A = 0_44 in
Iw = 57.Ox10� in
4
rw=0.36in
Z. = 145.x10' 63
X. = 0.00 in
Xo=0.00in
Sxe = 114.x10' in3
t � w � • aYrp r.
6 = 57.Ox10' in4
r„,=036in
Zyy = 145.40' in
Y"=O.00in
Yo=0.00in
Syy = 114.403 in
W = 57.Ox10-' 0
rx = 0.36 in
lyy = 57.Ox10a in4
ryy, = 0.36 in
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
PI,
a �,lyDollar 3'-0"x3'-0"x10'-0"Fabric Awning
Southeast & Southwest Elevations
-COE I Section
CARL E. THOMPSON, JR., P.E. Awning Frame & Wall Fastener Design
P.O. Box 1500, Englewood, TN 37329 Cale. by Date ChIM by
Phom: (423) 781-7336 Fax: (423) 781-7337 D W 2/9/2018 1 C.E.T
Job Rt
ProjL R.011316
DWG #: EMS33
Sheet no./rev. t��Li
4 �*
Date �
i
ASTM Aluminum Alloy designation 6063-T52 Fy = 27 ksi Fy welded = 12 ksi
Bending Stress on Span 2 (Non -Welded Region), UB = Mxl / S, = 4_2 ksi
Unity Check: Bending Stress, UCPa = 6B / (0.6 x Fy) = 26.0 %
Bending Stress on Span 2 (Non -Welded Region), cre = M.2 / S,a = 1_1 ksi
Unity Check: Bending Stress, UCPa = 6B / (0.6 x Fy) = 6_8 %
Bending Stress at Middle Support (Welded Region), 6B = abs(M1 / S,") = 5_1 ksi
Unity Check: Bending Stress, UCPa = 6B / (0.6 x Fy_wemed) = 71.4 %
WALL FASTENER DESIGN
1
STATE OF
Vertical Projection, V = (3 ft + 0 in) Horizontal Projection, H = (3 ft + 0 in) Diagonal Length, D = 4(V2+ H2) = 50.912 in
Distance Between Bottom Fastener & Top of Awning, Le = (2 ft + 9 in) = 33.000 in
Reaction at Bottom Wall Mounting Clip, Rclip = (w * D2 / 2) / L6 = 268.527 lbs
Vertical Shear Load per Wall Mounting Clip (Worst Case), Scup = Max(Rclip, R1 , R2) * (H/D) = 189.877 lbs
Horizontal Tension Load per Wall Mounting Clip (Worst Case), Tcup = Max(Rclip, R1 , R2) * (V/D)=189.877 lbs
Fastener Type
Fastener Diameter
in
Allowable Shear
Load(lbs)
Allowable Tension
Load(lbs)
#Wall Fasters Req'd
Per Mounting Clip
Through Bolt WBacker
3/8"
500 lbs
300 lbs
=1
#12 Self -Tapping Screw
0.216"
490 lbs
165 lbs
Je(J-7 appmg JCreW allowable Laaas per tt1(.'-CS Cvatuation Report t: YR-/Y76, Metal Nastenings (16-gauge base material thickness min)
V
it
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
Lill , Li I qslc
CARL E. THOMPSON, JR. P.E.
Serving the Industry Since 1984
Phone: (423)781-7336 Fax: (423)781-7337
Email:carl@tesengrs.com Website:tesengrs.com
Mailing Address: P.O. Box 1500, Englewood, TN 37329
Project #: 011417 DWG #: EB-6964
Family Dollar 3'-6" x 3'-6" x 14'-0" Fabric Awning - South (Entry) Elevation
Florida Building Code 6" Ed. (2017) (ASCE 7-10) VvLT = 160-mph Structural Calculations
Location: Family Dollar, 3214 Avenue D, Ft. Pierce, FL 34950
for
2 mfflem lmdustrjV S In C 0
Address: 6434 Burnt Poplar Road, Greensboro, NC 27409
Phone:336-668-2791 www.allenindustries. corn
P.O.# 165322
it
—c •.vim
No. 36539
STATE OF
tc••A
.•�
1111111161100
February 9, 2018
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
a, ;ily Dollar 3'-6"x3'-6"xl4'-0" Fabric Awning
COE OTI "
South (Entry) Elevation
Section
CARL E. THOMPSON, JR., P.E. Awning Frame 8 Wall Fastener Design
P.O. Box 1500, Englewood, TN 37329 Calc. by Date ChWd by
Phone: (423) 781-7336 Fax: (423) 781-7337 D W 2/9/2018 1 C.E.T
WIND LOAD & FASTENER DESIGN
WIND LOADING (ASCE7-10)
In accordance with ASCE740 incorporating Errata No. 1 and Errata No. 2
Using the components and cladding design method
Building data
JobF --
/111111/
N.- �tHoypS
�G
Prcja ,:. 011418
���
•.•.••.
DWG #: EB-6964
E
o. 5 9
Sheet no./rev.
2
*;
STATE OF
Date
2l9Y1018
��0�'•-
n
Tedds caleu;abon version 20.20
Type of roof Flat Length of building b = 100.00 it
Width of building d = 85_00 It Height to eaves H = 22_00 ft
Height of parapet hp = 3.00 ft
Mean height h = 22_00 it
General wind load requirements
Basic wind speed
V = 160.0 mph
Risk category
II
Exponent coef (11"26.6-1)
Kd = 0.85
Exposure category (d.26.7.3)
C
Enclosure class (d.26.10)
Enclosed buildings
Int pres coef +ve (T26.11-1)
GCp;y = 0.18
Int pres coef —ve (1726.11-1)
GCP;_n = -0_18
Parapet int. press. coef +ve
GCp;yp = 0.18
Parapet int. press. coef —ve
GCp; np = -0_18
Gust effect factor
Gr = 0.85
Topography
Topo factor not significant
Kn = 1.0
Velocity pressure
Velocity pressure coefficient
K� = 0.92
Velocity pressure
qh = 51.0 psf
Velocity pressure at parapet
Velocity pressure coefficient
K: = 0.94
Velocity pressure
qp = 52.4 psi
Peak velocity pressure for internal pressure
Peak velocd pressure — int q; = 51_03 psf FIT C 0 PY
Equations used in tablesL
Net pressure p = qn x [GCP -GCP;] F
Parapet net pressure p = qp x [GCP - GCpy]
Components and cladding pressures - Wall (Figure 30.44 and Figure 30A-2A)
Component
Zone
Length
Width
Eff. area
+GCP
GCP
Pres (+ve)
Pres (-ve)
(ft)
(ft)
(ft2)
(psi)
(psi)
amily Dollar
5
4.9
14.0
68.1
0.77
-1.00
PULT=48.4
PuLT=-60.0
1-6"x3'-6"xl4'-0"
PASD=29.0
PAso=-36.0
abric Awning
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
P'
_.. Jy Dollar 3'-6"x3'-6"x14'-0" Fabric Awning
South (Entry) Elevation
Section
CARL E. THOMPSON, JR., P.E. Awning Frame & Wall Fastener Design
P.O. Box 1500, Englewood, TN 37329 Calc. by Date Chk'tl by
Phone: (423) 781-7336 Fax: (423) 781-7337 D J W 2/9/2018 C.E.T.
FRAME DESIGN
Allowable Stress Design Pressure, PASD = 0.6 * 60.0 psf = 36.0 psf
Job 8:
.011418
DWG #:EB-6964 wC,E
Sheet noJmv. 4
. C Z
2/9/2018
g0�; STATE OF "40
Loading Method — Continuous Beam — Two Unequal Spans — Uniformly Distributed Load
Tributary Width, Width = (2 ft + 0 in) = 24.000 in
Span 1 Length, LI = (2 ft + 10.75 in) = 34.750 in
Moment at Middle Support,
Reaction at Top Support,
Reaction at Bottom Support,
Reaction at Middle Support,
Distributed Land, w = Width * PASD = 72.000 lbs/ft
Span 2 Length, L2 = (1 ft + 11.5 in) = 23.500 in
MI = (-1) * ((µ' * (L2)3 + w *(L,)3) / (8* (LI + L2))) _-707391 lb —in
RI = MI / LI + (w * LI) /2 = 83.8931bs
R3 = MI / L2 + (w * L2) /2 = 40.398 lbs
R2 = w * LI + w * L2 — RI — R3 = 225.208 lbs
Location of Max Moment Between Span I Supports, XI = RI / w=13.982 in
Max Moment Between Span I Supports, M.I = RI * XI — (w* (XI)2 / 2)= 586.509 lb in
Location of Max Moment Between Span 2 Supports, X2 = R3 / w = 6.733 in
Max Moment Between Span 2 Supports, M 2 = R3 * X2 — (w* (X2)2 / 2)= 136.002 lb in
RT 1 "X1"X0.125" WALL Calculation of section oronerties
A = 0.44 in
n
Iw = 57.Ox10' in4 Iw = 57.0x10-3 in4 I. = 57.040 in4
rw=0.36in rw=0.36in r.=0.36in
Z,x = 145.x10' ins Zyy = 145.40' in3
Xe=0.00in Ye=0.00in
Xp=O.00in YP=O.00in
Sx, = 114.x10' in Syy = 114.40' in
lyy= 57.040' 0
ryy = 0.36 in
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.
P Job R:
_::Jy Dollar 3'-6"x3'-6'k14'-0" Fabric Awning Projs.. r. 011418
South (Entry) Elevation DWG #: EB-6964
OE TO
Sect on Sheet no./rev.
,''C
CARL E. THOMPSON, JR., P.E. Awning Frame & Wall Fastener Design 4
P.O. Box 1500, Englewood, TN 37329 Cale. by Date Chk'd by Dale
Phone: (423) 781-7336 Fax: (423) 781-7337 D.J.W. 2/9/2018 1 C.E.T. 2/9/2018
ASTM Aluminum Alloy designation 6063-T52 Ft. = 27 ksi Fv welded = 12 ksi
Bending Stress on Span 2 (Non -Welded Region), 6B = Mxl / S. = 5_1 ksi
Unity Check: Bending Stress, UCpe = cre / (0.6 x Fy) = 31.8 %
Bending Stress on Span 2 (Non -Welded Region), 68 = Mx2 / Sm = 1_2 ksi
Unity Check: Bending Stress, UCpB = crB / (0.6 x F/.) = 7_4 %
Bending Stress at Middle Support (Welded Region), UB = abs(M1 / S p) = 6_2 ksi
Unity Check: Bending Stress, UCpa = 68 / (0.6 x Fy welded) = 86.2 %
WALL FASTENER DESIGN
111uur/1pi
♦♦``� T HOMp ''�i,
V E• �:; �i�
FAO•• STATE OF
'''11111111 110
Vertical Projection, V = (3 ft + 6 in) Horizontal Projection, H = (3 fir + 6 in) Diagonal Length, D = 4(V2+ H2) = 59.397 in
Distance Between Bottom Fastener & Top of Awning, Lo = (3 ft + 3 in) = 39.000 in
Reaction at Bottom Wall Mounting Clip, Rchp = (w * D2 / 2) / Lb = 271385 lbs
Vertical Shear Load per Wall Mounting Clip (Worst Case), Sccp = Max(Rcgp, RI , R2) * (HID) = 191.898 lbs
Horizontal Tension Load per Wall Mounting Clip (Worst Case), Tcsp = Max(Rcnp, R1, R2) * (V/D) = 191.898 Ibs
Fastener Type
Fastener Diameter
in
Allowable Shear
Load lbs
Allowable Tension
Load bs
#Wall Fasters Req'd
Per Mounting Clip
Through Bolt W/Backer
3/8"
500 lbs
300 lbs
=1
#12 Self -Tapping Screw
0.216"
490 lbs
1651bs
Ne[J-1 apping Screw Allowable Loaas per /CC-J J' Eva[uat/on Keport bJ'K-/Y76, Metal Nastenings (16-gauge base material thickness min.)
�.r": � s Mt
1 � P �
This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited.