Loading...
HomeMy WebLinkAboutCERTIFICATES3900'St..J9hns Parkwey Sanford, FL 32771 www.talloredfoamiric.dom' www.sprayfo'amfacts.coin' jED. l :NTIAL Florida'g 7iigfnal:Foamilnsulation Company Since 1986 Tot-IFree 800.6833155 Phone 40832.0333 Fax:.467-830-9174 Fireshell F10E Installation Certificate SCANNED BY St. Lucie County Job Sunshine Kitchen, 7550 Pruitt Research Rd., Fort Pierce, Name: ,FL 34945 Job #: 170832 Date Installation Completed: February 2018 Application Contractor: Tailored Foam of Florida Address: 3900 St. Johns Pk City/State/Zip: Sanford, FL 32771 Phone/Fax: 407-332-0333 / 407-830-9174 Area Coated Roof Deck Installation 21 mils Wet 14 mils Dry Crawl Space Installation Thickness 8 mils Dry Tailored Foam of Florida, Inc as an independent Contractor, Certify that the DC315 installed on this project was applied'in accordance with Icynene's;recommendations and specifications as stated on the product data sheet and the Specifications in the amount as indicated on this certification. Tailored Foam of Florida, Inc. CORE- FILL ISo'O, Danish, Notary Public Notary Public Stala of Florida M .Rhonda Danish My Commission FF 2W447 Exptrasavlinpla 3000 St. Johns Parkway Sanford; FL 32771 www,taildtodfbaminc.com www.sprayfcamfacts.com Florida's` Icynene 2 TAILORED FOAM of FLORIDA, lK COMM. ERCIAL&`AESIDENTIAL Orlglnal Foam Insulat[on`Company Since 1986 T" — Classic Ultra Select insulation Certificate Toll Free: 800=683=3155 Phone:407.332-0333 Fax: 407;830=9174 Job Name: Sunshine Kitchen 7550 Pruitt Research Rd., Fort Pierce FL 34945 Job #: 170832 Date Installation Completed: February 2018 Application Contractor: Address: City/State/Zip: Phone/Fax: Indicate Areas Insulated Exterior Stud Wall: Ceiling Insulation: Roof Deck Insulation: Crawl Space: Tailored Foam of Florida 3900 St. Johns Pkwy Sanford, FL 32771 407-332-0333 / 407-830-9174 Average Thickness Average Thickness Average Thickness Average Thickness R-Value R-Value 5.5" R-Value 20 R-Value Tailored Foam of Florida, Inc as an independent Contractor, Certify that the Icynene Insulation System installed on this project was applied in accordance with'Tho Icynene, Inc. recommendations and specifications as stated on the product data sheet and the Icynene Application Specifications in the amount as indicated on this certification. —Zj e4ennftAt, Vi rest n Tailored Foam of Florida, Inc. C0 of Fbrfda Icynene LD-G50v2-Classic Ultra Select Insulation System R-Value Chart Thickness R-Value Thickness R-Value 1" 3.7 5" 18 2" 7 5.5" 20 3" 11 6" 22 3, 13 8" 29 14 10" 36 ',�pVNfe/y SFD::O 39001t.;Johns Parkway Sanford,, FL 32771 www.talluiredtoamino.com www:sprayfoemfacts.con 'Florida's drlginarFoam insulation'CompanySince 198t CERTIFICATION OF INSULATION INSTALLATION Sunshine 10tchen 170832 7550 Pruitt Research Rd. Fort Pierce, FL 34945 INSTALLATION DATE: February 2018 T611 Frebi 800.68313155 Phone 407-#2.0333 Fax,.49TO10-9174 STATEMENT OF COMPLIANCE: We, the undersigned, hereby certify that the foamed -in -place thermal insulation has been installed in the above referenced building in accordance with the project plans and specifications, and in ,accordance, with'the manufacturer's recommendations. The material furnished and installed is of the type indicated below: MASONRY WALL INSULATION: .Manufacturer: Tailored Chemical Products, Inc. Material: CORE -FILL 500 Insulation Value Construction 'U' Valtte 'R' Value Parallel Heat Flow 8" block/60 lbs. density 0.07 14.2 12"block/60 lbs. density 0.05 20.0 Foam Density:.8 lb/cu.ft. WARRANTED FOR ONE (1) YEAR(S) FROM DATE OF OWNER'S ACCEPTANCE. Greg Zylstra, Vice President NEfl ieo�Fwnaeh FF p084470�P CORE --FILL.. �so