Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning 8 Development Services Building& Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. W82 Phone:(772)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 7550 Pruitt Research Ctr Rd City / State / Zip: Fort Pierce, FI 34945 Parcel#: 2314-411-0001-000/9 Zoning: PNRD APPLICATION INFORMATION Permit Number: 1803-0458 Permit Type: COMMERCIAL RENOVATII REVIEW COMMENTS 1 SCANNED BY Owner(s): St. Lucie County St Lucie County Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No CONTRACTOR INFORMATION Contractor Name: Michael E Jacquin ax Number: 772-466-2806 Business Name: Paul Jacquin &Sons Inc Business Addr: P O Box 4343 ,,1 Email: Mchael.Jacquin@Pjsi.Com City / State / Zip: Ft Pierce, FI 34948 REVIEWS AND COMMENTS Review Noe Status Reviewed By Date Started Date Completed Date Released FIRE DEPARTMENT REVIEW PENDING TO Jerger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 311512018 3/1512018 3/15/2018 Comment: PLANS EXAMINER ELECTRIC CO P ETE AltgLd. 'de 312012018 3/20/2018 3/20/2018 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 3120/2018 312012018 3/20/201B Comment: PLANS_EXAMINER—PLUMBING= 1 G,,,� Gres $InY1311512018 __ _ 3/16/2018 Comment: THE OCCUPANT COUNT ON THE PLAN REQUIRES 2 WC FOR WOMEN AND 2 WC FOR MEN TABLE 403.1 FPC 2017 PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 311612018 Comment: PERMIT SUBMITTED 03/15/2018' PLANS MUST BE DESIGNED TO THE 2017 FLORIDA BUILDING CODES. 6TH EDITION LIBRARY • INCLUDE THE 2017 FLORIDA BUILDING CODE, 2017 PLUMBING, 2017 MECHANICAL, 3/16/2018 2017 ACCESSIBILITY, 2017 FUEL GAS, NFPA 101-15 [ LIFE SAFETY 1, NEC NFPA 70-14 [ NATIONAL ELECTRIC CODE ] "' ENGINEER TO CHECK ALL CODE SECTIONS QUOTED ON PLANS AS MANY CODE SECTIONS HAVE CHANGED OR HAVE BEEN RE -NUMBERED' WILL REVIEW UPON RE -SUBMITTAL 3/16/2018 Comment: TENANT SPACE -D" [ EVENT SPACE ] WOULD BE CLASSIFIED AS ASSEMBLY OCCUPANCY' SEE 2017 FBC 303.4' CALCULATE OCCUPANT LOAD ACCORDINGLY AND ADD TO THE TOTAL OCCUPANT LOAD COUNT 3/16/2018 Comment: DESIGN PROFESSIONAL TO CLARIFY NOTES ON LS-1 AS A NON -SPRINKLED BUILDING • NOTE ON LIFE SAFETY PLAN STATES THAT THIS IS A FULLY SPRINKLED BUILDING ??? Planning & Development Services Building;& Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(712)462-6443 REVIEW COMMENTS comment: DESIGN PROFESSIONAL TO CALCULATE THE GROUP B SQUARE FOOTAGES ON PLANS AS GROSS S.F. 3/16/2018 AREA INSIDE THE EXTERIOR WALLS WITHOUT DEDUCTIONS FOR ANY OTHER SPACES OR AREAS. ASSEMBLY AREAS ARE CALCULATED AS NET AREA •• SEE FBC DEFINITIONS IN CHAPTER 2 Comment: DESIGN PROFESSIONAL TO SHOW THE REQUIRED RATED DOORS ON PLANS IN THE RATED WALLS AND 3/16/2018 CORRIDOR PER FBC TABLE 716.5 • SUBMIT THE PRODUCT APPROVAL [ TESTING CRITERIA ] FOR THE SAME DOORS' FBC 716 Comment: PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET 3/20/2018 OF PLANS CAN BE SUBMITTED PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 3/20/2018 Comment: CONTRACTOR TO PAY THE REQUIRED PLAN REVIEW FEES UPON RE -SUBMITTAL 3/20/2018 Comment: COMMENTS E-MAILED AS OF THIS DATE • PENDING ZONING REVIEW ZONING REVIEW PENDING Lydia Galbraith Comment: OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT Al 1803-0458 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATINIA ION DIVISION DSION SSCANNED UE FORT PIERCE, FL 34982-5652 BY nt (772) 462-1553 cie C0u y St. �u APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 7550 Pruitt Research Rd. Ft. Pierce, FL. 34945 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: Revisions to Plans from Comments dated 3-20-18 3. 4. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC 060473 ST. LUCIE COUNTY CERT. #: 18463 BUSINESS NAME: Paul Tacquin &Sons. Inc. QUALIFIERS NAME: Michael Tacauin ADDRESS: 7348 Commercial e CITY: Ft. Pierce STATE: Florida ZIP: 3 951 PHONE (DAYTIME): 772-465-2475 FAX: 772-466-2806 OWNER/BUILDER INFORMATION: NAME: SLC BOCC / TCERDA ADDRESS: 2300 Vir inia Ave. CITY: Ft. Pierce STATE: Florida ZIP: 349582 PHONE: 772- 62-1432 FAX: ARCHITECT/ENGINEER INFORMATION: SLCCC: 9n3/09 Revised 0426/2010 I D 2�20 V Le APR 1 1 Rm