Loading...
HomeMy WebLinkAboutENGINEERING® 1..1 / ® _ CARL E. THOMPSON, JR. P.E. Serving the Industry Since 1984 Phone: (423)781-7336 Fax: (423)781-7337 Email:carl@tesengrs.com Website:tesengrs.com Mailing Address: P.O. Box 1500, Englewood, TN 37329 Project #: 011217 DWG #: EB-6962 Family Dollar Wall Sign 4'-4" x 10'-4 1/2" - South (Entry) Elevation Florida Building Code 6th Ed. (2017) (ASCE 7-10) VuLT = 160-mph Structural Calculations Location: Family Dollar, 3214 Avenue D, Ft. Pierce, FL 34950 for � 2 ..f/ mIndustries e/hc. Address: 6434 Burnt Poplar Road, Greensboro, NC 27409 Phone:336-668-2791 www.aIIen1ndustries.com P.O.# 165322 is V No. 36539 STATE OF February 9, 2018 This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited. Pro, family Dollar 4'4" x 10'-41/2" Wall Sign COET Section CARL E. THOMPSON, JR, P.E. Wall Fastener Design P.O. Box 1500, Englewood, TN 37329 Calo, by Dale Chk'd by Phone: (423) 781-7336 Fax: (423) 781-7337 D.J.W. 2/9/2018 C.E.T Job Rel' Project;;: U11218 DWG #: EB-6962 Sheet no./rev. 2 Date 2/9/2018 = -o; zigir8 %O STATE OF . <C•" •. 4 O 001 O WIND LOAD & FASTENER DESIGN *14nrrrnl►��"`` WIND LOADING (ASCE7-10) In accordance with ASCE740 incorporating Errata No.1 and Errata No. 2 Using the components and cladding design method Tedds calculation version 2.0.20 Building data Type of roof Flat Length of building b = 100.00 ft Width of building d = 85_00 ft Height to eaves H = 22_00 it Height of parapet hp = 3.00 ft Mean height h = 22_00 It General wind load requirements Basic wind speed V = 160.0 mph Risk category II Exponent coef (f26.6-1) Kd = 0.85 Exposure category (G.26.7.3) C Enclosure class (d.26.10) Enclosed buildings Int pres cost+ve (1-26.11-1) GCp;_p = 0.18 Int pres coef -ve (T26.1 1-1) GCPI_n=-0_18 Parapet int. press. coef +ve GCP;_pP = 0.18 Parapet int. press. cost-ve GCP;_np = -0_18 Gust effect factor Gl = 0.85 Topography Topo factor not significant Kn = 1.0 Velocity pressure Velocity pressure coefficient K, = 0.92 Velocity pressure qh = 51.0 psf Velocity pressure at parapet Velocity pressure coefficient K, = 0.94 Velocity pressure qp = 52.4 psf Peak velocity pressure for Internal pressure Peak velocity pressure - int q; = 51_03 lost Equations used in tables Net pressure p = qh x [GCP - GCPI] Parapet net pressure p = qp x [GCP - GCPI1,] Components and cla ding pressures - Wall (Figure 30.4-1 and Fi ure 30.4.2A Component Zone Length Width Eff. area +GCP -GCP Pres (+ve) Pres (-ve) 011) (ft) (ft) (Psi) (psi) Family Dollar 5 4.3 10.4 45.0 0.80 -1.05 Pul.T=49.8 PULT=-62.9 4" x 10'-4 1/2" PASD=29.7 ASD-37.7 Overall Sign _�5_---2.0-=--7.2 -- 14L4--=----0:87- - A-.21-PUT=53.8-- qLT=-70.9= 4" x 7'-2 1/2" Cloud PASD=32.3 PASD=-42.5 Dollar 5 2.0 6.9 13.7 0.88 -1.22 UST=54.0 PULT=-71.2 4" x 6-10 3/8" Cloud ASD=32.4 PASD=-42.7 Family Dollar 5 - - 5.9 0.90 -1.26 PULT=55.1 PULT=-73.5 3" Dia Logo PASD=33.1 ASD=44.1 This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited. ' PM, COE•- raiilily Dollar 4'-4" x 10'4 1/2" Wall Sign *TO Section CARL E. THOMPSON, JR., P.E. Wall Fastener Design P.O. Box 1500, Englewood, TN 37329 Cale. by Date Chk'd by Phone: (423) 781-7336 Fax: (423) 781-7337 D.J.W. 2/9/2018 1 C.E.T 24" Family Cloud (Worst Case) Allowable Stress Wind Pressure, PAS' = 0.6' 70.9 psf = 42.5 psf Component Effective Area, AreaEae,;,, = (24 in) x (7 ft + 2.5 in) = 14.417 flz Total Pull -Off Wind Load, PTow = AreaEa elv, x PAso = 613.285 lbs Total Number of Fasteners in Tension, NF„,en„ = 6 Pull -Off Load Per Fastener, PFaa = PTood / NF o, = 102.214 lbs per Fastener Letter Dead Load Shear, SDa d = 175 lbs (Conservative Approximation) Shear Load Per Fastener, SF.. = SDcod / NF.n = 29.167 lbs per Fastener Job Project* 011218 DWG #: EB-6962 Sheet nolrev. Date 2/9/2018 5.9• ,i -o ��• STATEt/18 OF A p..' IVA L. Allowable Fastener Capacities Fastener Diameter Shear Allowable Tension Allowable 0 Fasters Req'd 8 Fasters Used Fastener Type (in) Load (Ibs) Load (lbs) Worst Case Worst Case Component Component Through Bolt WBacker 3/8" 500 lbs 30016s =3 6 24" Dollar Cloud Allowable Stress Wind Pressure, PAS, = 0.6' 71.2 psf = 42.7 psf Component Effective Area, AreaEa„dvo = (24 in) x (6 ft + 10.375 in) = 13.729 to Total Pull -Off Wind Load, Prow = AreaEae,;v, x PASD = 586.510 lbs Total Number of Fasteners in Tension, NF,,,,o,,, = 6 Pull -Off Load Per Fastener, PF�, = PTo„, / NF�e,,, = 97.752 lbs per Fastener Letter Dead Load Shear, SD=d = 175 lbs (Conservative Approximation) Shear Load Per Fastener, SF.. = SDmd / NF�o,en = 22M lbs per Fastener Allowable Fastener Capacities Fastener Diameter Shear Allowable Tension Allowable 0 Fasters Req'd 0 Festers Used Fastener Type (in) Load (Ibs) Load (Ibs) Worst Case Worst Case Component Component Through Bolt WBBacker 3/8" 500 lbs 300 lbs =2 6 Family Dollar 33" Diameter Logo Allowable Stress Wind Pressure, PAso=0.6.73.5 psf =44.1 psf Component Effective Area, Area,ae,ly, = (33 in)= • a / 4 = 5.940 fiz Total Pull -Off Wind Load, PTot.1= AreaEae,;,, x PAST) = 261.935 lbs Total Number of Fasteners in Tension , NFsmme,, = 4 Pull -Off Load Per Fastener, PFogee„ = PTmm / NFan,oe,. = 65.484 lbs per Fastener Letter I)ead_Load.ShearTS6;g ='100 lbs=—_ (Conservative Approximation) Shear Load Per Fastener, SF,,,,,,,, = SDe,d / NF,o,,,, = 25.000 lbs per Fastener Allowable Fastener Capacities Fastener Diameter Shear Allowable Tension Allowable 0 Fasters Req'd 0 Fasters Used Fastener Type (in) Load (Ibs) Load (lbs) Worst Case Worst Case Component Component Through Bolt WBacker 3/8" 500 lbs 300 lbs =1 4 Use Minimum of 16 total wall fasteners for the cloud & logo layout. This document is for the sole use of C.E.T. and his designees. Unauthorized use is strictly prohibited. 1 2'-9'0 MEDALLION , 5' , 7'-2yA (FAMILY CLOUD) I BOXED 7.56 ft2 w ACTUAL 5.94 H2 3 0 2 as w EMBOSSMENT LAYER y3 - 1/4- ON TOP OF g2 LAYER TOTAL EMBOSSMENT DEPTH= 3/4' EMBOSSMENT LAYER y2 - 1/4' ON TOP OF a1 LAYER TOTAL EMBOSSMENT DEPTH- 1/2' FACE TO BE PAN FORMED .177' THK. SOLAR GRADE POLYCARBONATE W/ 2' DEEP 90' FLANGE. EMBOSSMENT LAYER p1 - 1/4' DEEP GE TETRA MAX WHITE LEDS 15'/3D QTY. #GEMX71-2 WHITE LEDS POWERED BY ONE (1) OTY. GEPS12-60 POWER SUPPLY 120 VOLT, 1 AMP (4) WALL FASTENERS W/ WASHER, PAINTED WHITE SATIN FINISH RUBBER GASKET .177' THK. SOLAR GRADE POLYCARBONATE W/ SECOND SURFACE PAINTED BACKGROUND COLOR AND GRAPHICS (6) WALL FASTENERS 2'-9'0 MEDALLION (6) WALL FASTENERS LETTER EMBOSSMENT TO BE 1/2' DEEP 14.42 ft0 n)LL�i 6'-109§" (DOLLAR CLOUD) ` 13.73 111 EMBOSSING DETAIL MOUNTING DETAIL 3'-2" MCIRI Face GE TETRA MAX WHITE LEGS 35'/70 QTY. ®GEMX71-2 WHITE LEDS POWERED BY ONE (1) Cry. GEPS12-60 POWER SUPPLY 120 VOLT, 1 AMP XNCFALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILTTY OF THE CONTRACTOR OF RECORD (SMOOTH FINISH) p47230 ALUMINUM RIV-NUT FACE MOUNTING DETAIL NOT TO SCALE CABINET 0 N LETTER EMBOSSMENT TO BE 1/2' DEEP 2" X 2" ALUMINUM ANGLE FRAME GE TETRA MAX WHITE LEDS 35'/70 OTY. IGEMX71-2 WHITE LEDs POWERED BY ONE (1) QTY. GEPS12-60 POWER SUPPLY 120 VOLT. 1 AMP 6" DEEP CABINET SIGN MOUNTED FLUSH TO FASCIA .220' THK. FORMED ABS-KORAD®SIGN CABINET Y/ (SMOOTH FINISH) r 2 1/2" DEEP PAN -FORMED -_ .177' THK. SOLAR GRADE POLYCARBONATE SIGN STEEL ANGLE SUPPORTS FACE WITH EMBOSSED LOGO PROVIDED AND INSTALLED BEHIND THE WALL BY THE SIGN INSTALLER 3/80 ALL THREAD STEEL THRU BOLT AND 1"0 h STEEL CONDUIT SLEEVE. SEAL W/ SILICONE ADHESIVE h 48' ELECTRICAL _ -C PIGTAIL OUT BACK OF CLOUD SIGN JUNCTION BOX LOCATED BEHIND WALL -RUN 1/2'0 EXTRUDED ALUM. LIQUID TIGHT CONDUIT WRE TRAY THRU WALL AND SEAL WITH SILICONE ADHESIVE 2" X 2" ALUM. ANGLE :IL4T SIGN FRAME SEE THRU-BOLT ATTACHMENT RUBBER GASKET DETAIL PERIMETER OF THE AB S- SIDE SECTION DETAIL KORAD FORMED SIGN CABINET NOT TO SCALE .220' THK. FORMED ABS-KORAD®SIGN CABINET (SMOOTH FINISH) 2' X 2" ALUMINUM ANGLE (INTERNAL BRACING) THESE PLANS AND ALL PROPOSED WORK ARESUE TO ANY CORRECTIONS -r REQUIRED BY F!ct.0 INSPECTORS THAT MAY BENEiESSAPN:,%1ORDER TO E (FOUDOVER ) PHOSPHATE COMPLY Wr1', y5bb 4apucAELE 20010i , 3/5" - 16 SCREW SIZE L 0kb3 /e 91.LUCF, CO1'NT%• r REVIEVVEDFOR CO.% OR NOINSPRCl:d; 'NVILL BE MADE. ELECTRIC THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OFTHE NATIONAL ELECTRICAL CODE BfarOTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING S BONDING OF THE SIGN. GROUNDED ®®AIII, ELECTRICAL FILE NUMBER: ,- erim Fri JOB ".1 No.36539 AO ;• STA E OF i� •• A '�i �S • •: OR 110.1 ONA L ••� ��/I111I1���1 CARL E. THOMPSON, JR., P.E. WALL AREA (VARIES) GENERAL NOTE: 1. All design, detailing. fabricating and construction shall conform to the following codes and specifications: a. The Florida Building Code 0 Edition (2017). b. America Society of Testing and Malaise (AS1Y) saeorlmiime a Building Code Requirements for Reinforced concrete Well iCurrent non)) d. Code for Wattlinngg in C Building Construction o/ the American Welding Society. e. of structural Specification for the r Build, gsbby The and Erection icon of Seteof Steel for ru tinge by The American Institute of steel Construction Deep M (aurtmt Edition) L Alvmhum AeeaiaMm Alamhum pedgn Yorud (2005 Ea6m), 2. Structural Material Specifications: a. Structural Steel and Plates shall be A-36 b. ANmnum shapes shot be extruded from 6061-T6 allay. Welding filler alloy shall be 4043. c. W-Shape beams shall be (F,­50 ksi) Minimum d. Slmclwai tubing shall be AST9 A-500, Dada 8, (Fr=46 Ira) e. SWcbod ppsg M be ASN A-51 Doh 8. T1peE er S ( r35 b1, ASN A572 Grade 42 (Feti! Is) or MN A572 Doh 50 Vela Ira') (see droving for individual member specifications). 3. High strength bolts for connections shall be ASTM A-325. unless otherwise noted. 4. Welding electrodes shall comply wilh AWS D1.1-04, E70m (Ae -1" le M dme by •dda cotifiat for 1xdAed We tile) 5. Design Wind Speed, Vile,= 160 MPH (ASCE 7-10) Equivalent Wmd Load, Px,,px -44A PST or +33.1 PS ChC O Q2.-0. above the ground (3 Sec Ind Gads) Exposure :Z Risk Category II I,LQ- G=Q93. 6. Contractor shall arily al dmenews and eandilba In the field before esd on and na0h the Enoneor of my dsamadim 3/8'0 316A STAINLESS STEEL THRU-BOLT 2" STEEL ANGLE (OR EQUAL) SUPPORTS PROVIDED AND INSTALLED BEHIND THE WALL BY THE SIGN INSTALLER I'0 GALVANIZED STEEL CONDUIT SLEEVE THRU THE CORRUGATED METAL WALL TO PREVENT THE WALL FROM COLLAPSING AT SIGN ATTACHMENT 'SIZE CAN VARY UP TO 2" BY INSTALLER - SLEEVE IS OPTIONAL BY SITE DISCRETION) THRU BOLT ATTACHMENT DETAIL NOT TO SCALE NOTICE: This drawing is for permit procurement purposes only. C.E.T. is responsible for sign to wall attachment design only. All other components ate the responsibility of the sign manufacturer. If the existing wall is questionable or substandard, the installer shall notify the engineer immediately. nc4: Address: 6434 Burnt Poplar Road, Greensboro, NC 27409 Phone: (888) 294-2007 www.aI[an industries.corn I Family Dollar 4'-4" x ]0'Ay" Stacked Wall Sign - South (Entry) Elevation I Location: Family Dollar, 3214 Avenue D, Ft. Pierce, FL 34950 ® ® O CARL E. THOMPSON, JR., P.E. Serving The Industry Since 1984 Phone:(423)781-7336 Fax:(423)781-7337 Email:carl@tesengrs.com Website:tesengrs.com P.O. Box 1500, Englewood, TN 37329 1 BY: 11.9.10.a February 9, 2018 ).0.# 165322 E: 1 /2"=l'-0" •# 011218 # EB-6962 T 1 OF 1