Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 46 Certification for Design Load Compliance Project Name: DALE GOLDMAN Project Address: 3920 N. Al #304 Permit#:�Q-�Z� Occupancy Type: Construction Type: RE E 4h AUG 2 0 2018 Prmittin — Department St. Lucie county, FL INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY o Any accessory structure requiring a building permit St. Lucie County o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 BUILDING Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 160 ULT mph 124 ASO _LRFD End Zone Width: 52 ft 5. Mean Roof Height 130 ft Roof Pitch: 0 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: SEE PAA Zone 5: SEE PAA Garage: N/A 7. Design Loads: Floor: NIA PSF Roof/Dead: N/A PSF Roof/Live: NIA Balcony: NIA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered Forstructure? _Yes x Not Applicable Explain Why Not: PERMIT IS FOR INSTALLING WINDOWS AND DOORS 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: PERMIT IS FOR INSTALLING WINDOWS AND DOORS 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? N/A Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: -� I certify that, to the best of my knowledge.and-belief,-the attached plans & specifications have been designed to colmply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I',%W�elQfl 6Qt structural elements depicted on these plans provide adequate resistance to the design fo ;r%G• do•np�o, FRANK FARLEY, PE PE 40111 CA 28108 �. a NO 40111 • Q Print Name Cert # & Co. Cert Auth. •• v FARLEY ENGINEERING, LLC tire, Tartd aI 0 8800 N US1 STE 2 SEBASTIAN, FL 32958 �•, a Company Name &Address erl iY'F�'S•%fl(7'�4ii�����6 AUG 1 6 2018 8�p89016'� C U�-(1m;PY � ` Docmem Tltb: Structural Performance Doc NO: FRM 131-02 Rev No:7 °'m 1 O1 1 KEYS STONE Certification Authorization Report Required By: PRO B1-03 CAR & Product ID Number. 190 - 770.0 Issue Date: 12/13/2010 Revision Date: 4/5/2016 Expiration Date: 11/11/2020 Company Code: 190 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specked referenced standard. Actual fenestration product performance may vary based on marry factors, including installation, condition of the waNroof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that !hose products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keysonecertscom. Licensee Information: Product information: PGT Industries Model: 5470/5570 Impact SGD w & w/o Comer 1070 Technology Dr. PO Box 1529 Operator Type: SD Nokomis FL 34274 Config: H/J/S/Ast/Ciip/AII/SR, GS-3/16 Temp IG Max Width: 203 Max Height: 96 Referenced Standard: Product Rating: AAMA/WDMA/CSA 101/IS2/A440-11 I Class LC-PG60 2515x5144x2438 (99x203x96)-SD Qualifying Test Information: Test Report No: FTL-6367/6368/8545 Test Report Expiration: 11/11/2020 _ Digitally signed by Keystone Certifications, Inc. p a� •/ Steven Urich 564 Old York Road, Suite 5 sit 20 Etters, Pennsylvania 17319 Date: 2016.04.06 Phone: 717-932-8500 r 11:20:10-04'00' Fax: 717-932-8501 FIV•Y��J `■Al r� Docunent ntg: Structural Performance Dee No: FRM B1-02 Rev No. 7 ftw 1 Of: 1 KEYSTONE: Certification Authorization Report Requireday-, PRO B1-03 CAR & Product ID Number. 190 - 772.0 Issue Date: 12/13/2010 Revision Date: 4/5/2016 Expiration Date: 11/15/2020 Company Code: 190 This Certification Authorization Report (CAR) is issued by Keystone Certification;, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report Indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in afrwing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information In this report can be verified at www.keysbnecerts.com. Licensee Information: Product Information: PGT Industries Model: 5470/5670 Sliding Glass Door w/ & w/o Comer 1070 Technology Dr. PO Box 1529 Operator Type: SD Nokomis FL 34274 Config: H/J/S/Ast/Clip/AIU4-1/16SR, GS-3/16 Temp IG Max Width: 203 Max Height: 96 Referenced Standard: I Product Rating: AAMAJWDMA/CSA 101/IS2/A440-11 I Class LC-PG80 5144x2438 (99x203x96)-SD Qualifying Test Information: ITest Report No: I FTL-6369 Test Report Expiration: 11/1512020 4.& z G/1 Digitally signed by Steven Urich Date: 2016.04.06 11:22:12 -04'00' Keystone Certifications, Inc. 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 Phone: 717-932-8500 Fax: 717-932-8501 W W W.KEYSTONECERTS.COM "ram— KEYSTONE Doomont Title: Structural Performance Doc No: FRM 13"2 Ron, No: 7 "w 1 Of:1 -'�-�--- "� Certification Authorization Report Regtoredey. PROBl-03 CAR & Product ID Number: 190 - 771.0 Issue Date: 12/13/2010 Revision Date: 4/5/2016 Expiration Date: 11/21/2020 Company Code: 190 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the speeded referenced standard. Actual fenestration product performance may vary based on marry factors, including installation, condition of the walVroof substrate and the age of the product and Installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keysionecerts.com. I Licensee Information: I Product Information: PGT Industries 1070 Technology Dr. PO Box 1529 Nokomis FL 34274 Model: 5470 Sliding Glass Door w & w/o Comer Operator Type: SD Config: H/J/S/Clip/AIV3-1/2SR, GS-3/16 Temp IG Max Width: 241 Max Height: 96 Referenced Standard: I Product Rating: AAMANVDMA/CSA 101/IS2/A440-11 I Class LC-PG60 6121x2438 (241x96)-SD Qualifying Test Information: Test Report No: Test Report Expiration: FTL-6370 11/21/2020 Authorized'Si!gnature: Digitally signed by Keystone Certifications, Inc. Steven Urich 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 Date: 2016.04.06 Phone: 717-932-8500 11:29:34-04'00' Fax: 717-932-8501 W ww.KEY5TONECERTS.COM ;— -1--i -- Oocmenl Tift Structural Performance Doc No: FRM B1-02 Rev No: 7 Pam , or. , ►CEYSTONE, Certification Authorization Report Required sy: PRO B1-03 CAR & Product ID Number: 190 - 774.0 Issue Date: 12/15/2010 Revision Date: 4/5/2016 Expiration Date: 11/23/2020 Company Code: 190 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardzed evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wa[Vroof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keysfinecerts.com. Licensee Information: Product Information: PGT Industries Model: 5570 Impact SGD w & w/o Comer 1070 Technology Dr. PO Box 1529 Operator Type: SD Nokomis FL 34274 Config: H/J/S/Ast/Clip/AII/3-1/2SR, GS-3/16 Temp IG Max Width: 203 Max Height: 120 Referenced Standard: Product Rating: AAMAIWDMA/CSA 101/IS2/A440-11 I Class LC-PG60 5144x3048 (203x120) Neg DP=65 Qualifying Test Information: Test Report No: FTL-6371 Test Report Expiration: 11/23/2020 — Authorized Signature; Keystone Certifications Digitally signed by y r Inc. Steven Urich 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 Date: 2016.04.06 Phone: 717-932-8500 11:26:58-04'00' Fax: 717-932-8501 W W W.KEYSfONECERTS.COM