HomeMy WebLinkAboutNOAM�IAMFA NII MIA-DADE COUNTY
\R�Ip�IY PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 StreM Room 208
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315 2599
NOTICE OF ACCEPTANCE (NOA) w .miamidade eov/economy
PGT Industries, Inc.
1070 Technology Drive SCANNED
North Venice, FL 34275 By
SCOPE: St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "HR-5510" PVC Horizontal Rolling Window — L.M.I.
APPROVAL DOCUMENT: Drawing No. MD-HR5510-01 titled "Horizontal Roller - LM", sheets 1
through 18 of 18, dated 05/15/15, with revision B dated 03/27/17, prepared by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with
the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECN:_A=copy-of=this-entii-e-NOA shall-6e provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 16-0714.17 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Jorge M. Plasencia, P.E.
NOA No. 17-0411.08
Expiration Date: September 24, 2020
Approval Date: August31,2017
Page 1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No.15-0903.10)
2. Drawing No. MD-HR5510-01 titled "Horizontal Roller - LM", sheets 1 through 18 of
18, dated 05115115, with revision B dated 03/27/17, prepared by manufacturer, signed
and sealed by Anthony Lynn Miller, P.E.
TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a PVC sliding glass door,
a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS
spacer system, Duraseal® spacer system, Super Spacer® NXTTM spacer system and XL
EdgeTM spacer system at insulated glass, prepared by Fenestration Testing Laboratory,
Inc., Test Reports No. FTL-8717, F17L-8968 and FTL-8970, dated 11116115,
06/07/16 and 06/02/16 respectively, all signed and sealed by Idahnis Ortega, P.E.
(Submitted under previous NOA No.16-0714.17)
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
5) Large Missile Impact Test per FBC, TAS 201-94
6) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of series 5410 and series
5510 PVC horizontal sliding windows, prepared by Fenestration Testing Laboratory,
Inc., Test Report No. FTL-8072, dated 02/03/15, signed and sealed by Idalmis Ortega,
P.E.
(Submitted under NOA No. 15-0903.10)
3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
5) Large Missile Impact Test per FBC, TAS 201-94
6) Cyclic Wind Pressure Loading per FBC TAS_2035_4= - - -
—�=-along=with`marrked-up=drawingss and mstal)ation diagram of series 5510 PVC
horizontal sliding windows, prepared by Fenestration Testing Laboratory, Inc., Test
Report No. FTL-8073, dated 02/18/15, signed and sealed by Idabnis Ortega, P.E.
(Submitted under NOA No. 15-0903. 10)
Jorge WL Plasencia, P E.
Prduct Control Unit Supervisor
NOA No.17-0411.08
Expiration Date: September 24, 2020
Approval Date: August 31, 2017
E-1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile hnpact Test per FBC, TAS 201-94
3) Cyclic Wmd Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of series 5510 PVC
horizontal sliding windows, prepared by Fenestration Testing Laboratory, Inc., Test
Report No. F1'L-8074, dated 11/06/14, signed and sealed by Idalmis Ortega, P.E.
(Submitted under NOA No.15-0903.10)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-51
Edition (2014), dated 08/28/15, prepared by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
(Submitted under NOA No. 15-0903. 10)
2. Glazing complies with ASTM E1300-09
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
`tt_/:74INN 11-Sy s • JLaiO4F.I.V-1 OINK:
1. Notice of Acceptance No.16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers" dated 01/19/17,
expiring on 07/08/19.
2. Notice of Acceptance No.14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/18.
3. Notice of Acceptance No.16-0712.03 issued to ENERGI Fenestration Solutions USA
for their "White Rigid PVC Exterior Extrusions for Windows and Doors" dated
08110/17, expiring on 02/28/18.
4. Notice of Acceptance No.16-0712.04 issued to ENERGI Fenestration Solutions USA,
Inc. for their "Bronze and Lighter Shades of Cap Coated White Rigid PVC
Exterior Extrusions for Windows and Doors" dated 09115116, expiring on 04/16/20.
5. Notice of Acceptance No.16-0712.05 issued to ENERGI Fenestration Solutions USA,
Inc. for their "Performance Core Rigid PVC Exterior Extrusions for Windows
and Doors" dated 09115116, expiring on 04/16/20.
Jorge M. Plaseacia, P.E.
Pr act Control Unit Supervisor
NOA No.17-0411.08
Expiration Date: September 24, 2020
Approval Date: August 31, 2017
1AIR3
PGT Industries. Ine.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance, complying with FBC-51 Edition (2014) and FBC-
6th Edition (2017), dated 08/02/17, issued by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
2. Statement letter of no financial interest, dated 03/31/17, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No.16-0125 issued by the Product Control Section, dated March 09, 2016,
signed by Ishaq Chanda, P.E.
(Submitted under previous NOA No. 16-0714.17)
4. Proposal issued by Product Control, dated 8/27/14 and revised on 9/10/14, signed by
Jaime Gascon, P.E. Supervisor, Product Control Section.
(Submitted uuderNOA No.15-0903.10)
E. OTHERS
1. Notice of Acceptance No. 16-0714.17, issued to PGT Industries, Inc. for their Series
"HR-5510" PVC Horizontal Rolling Window - L.M.I., approved on 09/01/17 and
expiring on 09/24/20.
Jorge M. Plasencia, P.E.
ez4roduct Control Unit Supervisor
NOA No.17-0411.08
Expiration Date: September 24, 2020
Approval Date: August 31, 2017
E-3