HomeMy WebLinkAboutMISC LETTER18o3-ocogy RF�FIVED MARCO T. PEREZ P.E. Po NOV 16P018 15131 SW 51 ST • Davie, FL 33331 • CEL 954-557-4971 • LIC # 45579 PLANINING & DEVELOPMENT SERVICES BUILDING CODE & REGULATION DIVICION 2300 VIRGINIAAVENUE, FORT PIERCE, FL. 34982 LAKEWOOD PARK PLAZA, LLC 5190-5198 TURNPIKE FEEDER RD. SAINT LUCIE COUNTY, FL. RE: WALL OPENING ENCLOSURE Attention: Building inspector November 14t', 2018 SCANNED BY St. Lucie County I, Marco T. Perez., Florida register Professional Engineer, I have inspected the enclosure of the wall opening at the address mentioned above, specifically between units 5196 and 5198 and I certify that this repair was properly done by using the same materials as possible to match the existing conditions of the wall. Enclosure breakdown: 2X4 wood studs @ 16" o.c., 2X4 p.t. wood base plate power fastened to floor 1 layer of 5/8" drywall @ each side and R-11 insulation. Screwed @ 8" O.C. this opening enclosure complies with the FBC 2504.1.1 Wood framing and TABLE 2508.1 installation of gypsum construction Should you have any question or concern please contact me to the cellphone lister above Marco T. Perez P.E. CREA Consultants. LLC Manager CONTRACTOR COPY MARCO T. PEREZ P.E. 151315W 515T • Davie, FL 33331 • CEL 954-557-4971 • LIC # 45579 PLANINING & DEVELOPMENT SERVICES BUILDING CODE & REGULATION DIVICION 2300 VIRGINIA AVENUE, FORT PIERCE, FL. 349k LAKEWOOD PARK PLAZA, LLC 5190-5198 TURNPIKE FEEDER RD. SAINT LUCIE COUNTY, FL. RE: Revision for tenant separation in sheet A-3 Attention: Building inspector March 5, 2019 The reason of this letter is to clarify the revision #3 of the sheet A-3, where previously was submitted with the wrong information regarding the tenant separation. As stated on the letter of certification.. already submitted, the tenant separation consists of 1 hr. rate wall with 2x4 wood framing and 1 sheet of 5/8" drywall at each side. This is a proven assembly No. UL U305., attached to this letter. Also as a part of the revision 3 the bathrooms interior finish indicates ceramic tile up to 4' Should you have any question or concern please contact me to the cellphone lister above 1. l Marco.T. Perez p). r CREA Consultants, LLC Manager ' J / i ' Y RfiC�'F Noels ° MARCO T. PEREZ P.E. pes��MB 15131 SW 51 ST • Davie, FL 33331 • CEL 954-557-4971 • LIC # 45579 PLANINING & DEVELOPMENT SERVICES BUILDING CODE & REGULATION DIVICION 2300 VIRGINIAAVENUE, FORT PIERCE, FL. 34982 LAKEWOOD PARK PLAZA, LLC 5180-5188 TURNPIKE FEEDER RD. SAINT LUCIE COUNTY, FL. RE: ROOF FASCIA REPAIRS Attention: Building inspector November 4', 2018 I, Marco T. Perez., Florida register Professional Engineer, I have inspected the repaired roofing fascia at the address mentioned above and I certify from the best of my knowledge and professional judgement that this repair was properly done by using the same materials as possible to match the existing conditions of the fascia. 5/8" exterior grade P.W. fascia on with 90# felt with wirelath and plaster on 2x4 p.t. blocking. The affected portion of the blocking 1x3 below the drip edge was also replaced. In addition, this repair complies with the FBC R 4409.1.2 Should you have any question or concern please contact me to the cellphone lister above ,1 1 , Marco T. Perez P.E.Al 41� 10a CREA Consultants, LLC Manager