Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOADPlanning & Development Services Department Building & Code Regulations Division RECEIVED 2300 Virginia Avenue; Fort Pierce, FL 34982 — (772) 462-15 3 A?' � S! 'v18 Certification for Design Load Compliance Project Name: Island Crest -Sprint MI54XC013 ST. Lucie Counrv. Permitting - - Project Address: 10680 South Ocean Drive, Jensen Beach, FL 34957 Permit#: Occupancy Type: Construction INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED Residential Addition o Any accessory structure requiring a building permit BY o Any non-residential structure. St. Lucie County * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 127.9 mph X ASD _LRFD End Zone Width: N/A ft 5. Mean Roof Height 142 ft Roof Pitch: N/A :12 Parapet: 3 It 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: N/A Zone 5: N/A Garage: N/A 7. Design Loads: Floor: NIA PSF Roof/Dead: NSA PSF Roof/Live: NSA Balcony: WA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: Loading on appurtenance considered only 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: Loading on appurtenance considered only 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes _..I.certIfy-that4.to,thpP st of -my knowledge and belief, -the attached plans.& s ecP ifications have been -designed -to----- ---- comI4V14SkX jGpIP64structural portions of the building codes currently adopted and enforced by St. Lucie Coeu�ity. IJaI`SLcwt3foaJ t st(vcctural elements depicted on these plans provide adequate resistance to the design f4l'tce5specMed: `SF 7 86 Jiang J. Yu 78286 * : Print Name Cent # & Co. Cent Auth. * Dewberry Engineers Inc. .A T 800 North Magnolia Ave. Suite 1000, Orlando, FL 32803 i' NA' £;%%% Company Name & Address Revised 07/25/2014 '