HomeMy WebLinkAboutPLANSPREPARED FOR: IX A'.I 1110- EMERGENCY: CALL 911 CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING: —FLORIDA BUILDING CODE, 2017 6TH EDITION ANSI/EIA/TIA-222—G —NATIONAL ELECTRICAL CODE 2014, NFPA 70-2014 —FLORIDA FIRE PREVENTION CODE 2017 6TH EDITION —FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION DESIGN CRITERW 2017 FLORIDA BUILDING CODE, 6TH EDITION, BASED UPON ULTIMATE 3—SECOND GUST WIND SPEED OF 151 MPH CONVERTED TO A NOMINAL 3—SECOND GUST WIND SPEED OF 117 MPH PER SECTION 1609.3.1 AS REQUIRED FOR USE IN THE TLA-222—G STANDARD PER EXCEPTION #5 OF SECTION 1609.1.1 EXPOSURE CATEGORY C WITH A RISK CATEGORY II I DO NOT SCALE DRAWINGS I CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE AND SHALL NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. VICINITY MAP 'me JW .----- -- - i 4 P\ PROJECT [] [j N r rrr Sprint ] ST. LlCIE COUN" aLiXi: DATE' d Et -EC: DATE: DATE. /y � CAM SPRINT NAME M 113XC 161 SPRINT PROJECT DO MACRO UPGRADE SPRINT CASCADE M 113XC161 ATC ASSET NAME FORT DRUM ATC ASSET NUMBER • SITE ADDRESS 1, 25560 MINUTE MAID RD FORT PIERCE, FL 34945 GI'M SIDES r[AR zkiG. fT PROJECT TEAM AMERICAN IROFIRNIGYg TOW= R FROM Me aolYNRna ere endless CORPORATION 1401 TOWN PLAZA CT. SUITE 2040 116 HUNTINGTON AVENUE, IITHFLOOR WINTER SPRINGS, FL 32708 BOSTON, MA MIT 16 OFFICE #: (678) 444-4463 PROJECT MANAGER ENGINEER PROJECT DESCRIPTION SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS TELECOMMUNICATION FACILITY: AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY • INSTALL (6) PROPOSED PANEL ANTENNAS THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE • INSTALL (8) PROPOSED RRU'S PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. • INSTALL (3) 1.25• HYBRIFLEX CABLES CONTRACTOR SHALL NOTIFY OWNER FOR ACCESS TO SITE. THESE PLANS HAVE BEEN DEVELOPED FOR THE MODIFICATION OF AN _EXISTING UNMANNED TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY SPRINT IN ACCORDANCE WITH THE SCOPE OF WORK PROVIDED BY SPRINT. INFINICY HAS INCORPORATED THIS SCOPE OF WORK IN THE PLANS. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS ACCOMPANIED BY A PASSING STRUCTURAL STABILITY ANALYSIS PREPARED BY A LICENSED STRUCTURAL ENGINEER. STRUCTURAL ANALYSIS MUST INCLUDE BOTH TOWER AND MOUNT. SCANNED BY St. Lucie County PROJECT SUMMARY TOWER OWNER: AMERICAN TOWER CORP. 116 HUNTINGTON AVENUE BOSTON, MA 02116 617-375-7500 LATITUDE: 27.53931' N LONGITUDE:—6D.60285• W ZONING JURISDICTION, ST. LUCIE COUNTY SPRINT CONSTRUCTION MANAGER: TOM POITRAS THOMAS.POIIRAS®SPRINT.CCM SHEET INDEX NO. DESCRIPTION T-1 TITLE SHEET & PROJECT DATA N-1 GENERAL NOTES N-2 GENERAL NOTES N-3 GENERAL NOTES C-1 COMPOUND PLAN C-2 TOWER ELEVATION AND ANTENNA ORIENTATION C-3 DETAILS C-4 DETAILS C-5 ANTENNA & CABLE SCHEDULE G-1 GROUNDING DETAILS RF-1 PLUMBING DIAGRAM RF-2 ANTENNA & CABLE COLOR CODING Sprint 6580 Sprint Parkway Overland Par, Kansas 66251 INFINIGY8 FROM ZERO TO INFINIGY the solallona are endless III, T. PLAZA DT. SUITE DWG WINTER SPRINGS, FL KNOB De-.0"l. JOB NUMBER 317-404 AM=RICAN TOW=R CORPORATION 116 HUNTINGTON AVENUE, IITH FLOOR BOSTON. MA U116 `111111111f///� OPHER ✓ E N No 59739 :2 s-oa-ls ESTATE . �` �� OF NAL6N���. THESE DOCUMENTS ARE CON FIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. MI13XC161 25560 MINUTE MAID RD FORT PIERCE, FL 34945 TITLE SHEET & PROJECT DATA SHEETNUMSER: T-1 PREPAREDFOR: BASIC REQUIREMENTS A. MEET ALL REQUIREMENTS OF JURISDICTIONS. B. IF EQUIPMENT FURNISHED BY COMPANY DOES NOT MATCH THE EQUIPMENT LISTED ON THE REDS AND SHOWN ON THE PERMITTING DRAWINGS, RESOLVE DISCREPANCY THROUGH INSTALLER'S CONSTRUCTION MANAGER AND COMPANY'S POINT OF CONTACT. C. CABLE INSTALLATIONS o. ALL CABLES MUST BE OUTDOOR RATED AND HAVE W RESISTANT OUTER JACKETS. b. CABLE BENDS MUST NOT EXCEED MANUFACTURER'S ALLOWABLE CABLE BEND RADII. c. AT RADIOS INSTALL SERVICE LOOPS FOR POWER, FIBER AND ETHERNET SECURED AT LEAST TWICE AT 180 TO THE STRUCTURE. d. SPARE FIBERS MUST BE ENCASED IN A LOW PROFILE WEATHER TIGHT ASSEMBLY. 0. FIBERS MUST BE FIELD -TERMINATED WITH LC -TYPE CONNECTORS. E. CONDUITS IN EARTH: PROVIDE PVC. CONDUITS EXPOSED AND IN FACILITIES: PROVIDE RGS. HAND DIG TRENCHES IN COMPOUNDS. F. SECURE AND SUPPORT CONDUITS AND CABLES ON NO MORE THAN 48' INTERVALS. G. ON TOWER SITES RGS CONDUITS MAY BE SURFACE MOUNTED AWAY FROM WALKWAYS AND ACCESS/EGRESS PATHS. IF INSTALLATIONS IN WALKWAY AND ACCESS/EGRESS PATHS CANNOT BE AVOIDED IDENTIFY THE CONDUIT ENVELOPE/TRIP HAZARD BY ALTERNATION YELLOW AND BLACK STRIPES PAINTED ON CONCRETE AND CONDUIT. Sprint 011 658D Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: INFINIGY9 FROM ZERO TO INFINIGY he Selaflane are endlem 1401 TOM PLUM CT. SUITE two WINTER SPRINGS, FL 394E a .PSP...w3 JOB NUMBER 117-104 2) SPRINT -FURNISHED EQUIPMENT A. INSTALL THE FOLLOWING EQUIPMENT AT LOCATIONS AND AZIMUTHS SHOWN ON THE CONSTRUCTION DRAWINGS. /��� �ERICAN a. PANEL ANTENNAS D. RADIOS TOWER c. GPS ANTENNAS J. FILTERS CORPORATION e. 120 VOLT DIN -RAIL CIRCUIT BREAKER ASSEMBLY 116 HUNTINGTON AVENUE, IITH FLOOR aOSTON, NA 02116 3) TOWER INSTALLATIONS ENGINEERING UCENSE: A. MEET ALL REQUIREMENTS OF THE TOWER OWNER. B. INSTALL CORRUGATED FLEXIBLE CONDUIT UP THE TOWER TO COMPANY'S RAD CENTER. ABLES ARE PROVE HANGING, WEL AS INNERCFITTNGS. OR CONDIT CLAMPS NDDOWN ANDOPROVDEACAB 1%%J111111/EA1C. kk D. CONDUIT RISER: AT TOP OF TOWERUTURNN CONDUITRIPS ELT RMINATIONS EXTENDCABLESTO RADIOS \•,••••••ENSFq,99,� OOPS AD WE`y,IOPHER E. ATPICEED AND BRIDGE RUNRED TO CABLES INN RGS CONDUIT.UCTURE. AT ONDUITUTILIZEFCONDUITS TOWEMAKE COM ACTXIT FROM TOR, PVIDE I90LDEGREENTURNSEP HOLES. 4) AC POWER TIE-IN f� N 59739 2 A INSTALL SPRINTS 120 VOLT DIN -RAIL CIRCUIT BREAKER ASSEMBLY IN THE EXISTING POWER PROTECTION CABINET TELCO SECTION. B. INSTALL A 20 AMPERE MOLDED CASE CIRCUIT BREAKER IN AVAILABLE SPACE IN THE ADJACENT PPC POWER SECTION LOAD CENTER. �� 5) GROUNDING � 9 ; 5-04-18 : � � A. 120 VOLT CIRCUITS: POWER CABLES MUST BE 3-WIRE WITH EQUIPMENT GROUND CONDUCTOR. ��•,• ATE OF , 4Q B. SUPPLEMENTAL GROUNDING: ALL GROUNDING HARDWARE MUST BE UL STAMPED AS SUITABLE FOR GROUNDING HARDWARE. C. RADIOS: BOND RADIO TO THE TOWER TOP OR SECTOR GROUND BAR WITH 16 AWG BARE SOLID TINNED COPPER WIRE (GREEN INSULATED ON �j ; P • ���� ��di•••j�%% ,oilSlONAL�N�\�� D. DIN-RAILSCIRCUT BREAKER ASSEMBLY: BOND SURGE ARRESTOR TO PPC TELCO BOARD GROUND BAR. 6) MINOR MATERIALS A. CONDUIT a. RIGID GALVANIZED STEEL CONDUIT (RGS): UL LISTED, COMPLIANT WITH ANSI STANDARD C80, HOT -DIP GALVANIZED, WITH DRAWING NOTICE: THREADED FITTINGS. MANUFACTURES: ALLIED, REPUBLIC, WHEATLAND OR EQUAL. THESE DOCUMENTS ARE CONFIDENTIAL AND ARE b. CORRUGATED FLEXIBLE CONDUIT: ONDUIT OR EQUAL THE SOLE PROPERTY OF SPRINT AND MAY NOT BE METAWC CONDUIT (LFMC): UL LABELED, W RESISTANT, FLAME RETARDANT PVC JACKET, HOT -DIP c. LIQUID -TIGHT FLEXIBLE C REPRODUCED, DISSEMINATED OR REDISTRIBUTED GALVANIZED, GREY, MANUFACTURER'S AFC, ANACONDA, SOUTHWIRE OR EQUAL WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. d. PVC CONDUIT: SCHEDULE 40. CARLON OR EQUAL. e. CABINET HUBS AND CABLE TERMINATION FITTNGS: OZ GEDNEY OR ROXTEC REWSIONs: DESCRIPTION I DATE I BY IREVI B. COAXIAL CABLE JUMPERS: 1/2` LDF-4. MANUFACTURERS: COMMSCOPE, RFS OR FCT. C. FASTENERS AND HARDWARE a. TO SECURE RACEWAYS, UTILIZE NON CORRODING NON MAGNETIC METAWC FASTENERS AND HARDWARE SUITABLE FOR THE PURPOSE. D. POWER CABLES- 3/C 012 SCOW BY SOUTHWIRE OR EQUAL. E. ETHERNET CABLES AND CONNECTORS: OUTDOOR RATED, CAT 5E, BELDEN OR EQUAL. ISSIID) FOR EONSTRUCRO4 02/12/16 m O F. FIBER CABLES: CORNING "FREEDOM FAN OUT' OUTDOOR RISER CABLE, 4F, SINGE MODE, OR EQUAL. ASSAILED FOR RLV,LW oI/o4pe JR A G. RF TRANSPARENT PAINT FOR ANTENNA CONCEALMENT: SELECT NO/LOW CARBON PAINTS, WITH NO/LOW TITANIUM DIOXIDE, AND WITHOUT SUSPENDED METAL PARTICLES (ALUMINUM, ZINC, COPPER, ETC.) SITE NAME: 7) COLOR CODING FORT DRUM A. COLOR CODE CABLES AND CONDUITS AS REQUIRED BY SPRINT STANDARD TS-0200. 8) TESTING AND CONSTRUCTION COMPLETE. SITE CASCADE: A SWEEP ALL COAXIAL CABLES ACCORDING TO SPRINT STANDARD TS-0200. B. PANEL ANTENNA AUGNMENT - USING ELECTRONIC ALIGNMENT TOOL. AXIMUTH/DOWNTILT +/-1 DEGREE. C. LEAVE EQUIPMENT DE -ENERGIZED UNTIL INSTRUCTED BY THE COMMISSIONING AND INTEGRATION TEAM TO ENERGIZE. MII3XC161 D. OTHER REQUIREMENTS AND DELNERABLES MAY BE REQUIRED BEFORE THE CONSTRUCTION COMPETE MILESTONE CAN BE ACTUALIZED IN SITERRA (SPRINT'S DATABASE -OF -RECORDS). aTE AnoREss: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 GENERAL NOTES ILm 9. PREPARATION A. SURFACES: ALL CONNECTIONS SHALL BE MADE TO BARE METAL. ALL PAINTING SURFACES SHALL BE FIELD INSPECTED TO ENSURE PROPER CONTACT. ALL GALVANIZED SURFACES ON WHICH GALVANIZING HAS BEEN REMOVED BY CUTTING, DRILLING, OR ANY OTHER OPERATION SHALL BE RE —GALVANIZED IN ACCORDANCE WITH ASTM A780 USING "ZINC RICH" COATING AS MANUFACTURED BY ZRC CHEMICAL PRODUCTS COMPANY (LOCATED IN QUINCY, MASSACHUSETTS). OR ACCEPTABLE EQUAL. NO WASHERS ARE ALLOWED BETWEEN ITEMS BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON —OXIDIZING AGENT ("COPPER SHIELD") APPLIED PRIOR TO INSTALLATION. B. GROUND BAR: ALL COPPER GROUND BARS SHALL BE CLEANED, POLISHED AND A NON —OXIDIZING AGENT ("COOPER SHIELD"" APPLIED. NO FINGER PRINTS OR DISCOLORED COPPER SHALL BE PERMITTED. 10. BUILDINGS A. ELECTRICAL CONTRACTOR SHALL PERFORM REQUIRED TESTING IN GROUNDING SYSTEM ONCE GROUNDING SYSTEM IS COMPLETELY CONSTRUCTED AND BEFORE SERVICE POWER AND GROUND IS CONNECTED (SEE NOTE 13A FOR TEST DESCRIPTION). B. A #4/0 AWG COPPER CONDUCTOR SHALL BE ROUTED FROM MASTER GROUND BAR AT BTS SITE TO MAIN METAL COLD WATER PIPE AND BONDED TO PIPE WITH BRONZE 2—HOLE PIPE CLAMP. CLAMP SHALL BE CONNECTED TO WATER PIPE WITHIN 5 FEET OF ENTRY OF PIPE INTO BUILDING WITH NO DEVICES BETWEEN ENTRY POINT AND CONNECTION AND SHALL COME IN CONTACT WITH PIPE FOR A MINIMUM DISTANCE OF 4 INCHES. 13. SPRINT GROUNDING REQUIREMENTS A. CONTRACTOR SHALL INSPECT AND TEST ANY NEW OR EXISTING SPRINT GROUNDING SYSTEM WITH A BIDDLE—MEGGER TESTER UTILIZING THE FALL OF POTENTIAL METHOD AND CONTACT CONSTRUCTION MANAGER IF RESISTANCE EXCEEDS 5 OHMS AND SHALL FIELD MODIFY GROUNDING SYSTEM AS NECESSARY TO ACHIEVE COMPLIANCE. TEST RESULTS AND CONCLUSIONS SHALL BE RECORDED FOR PROJECT CLOSE—OUT DOCUMENTATION. B. COAX CABLE OUTER CONDUCTORS (SHIELDS) SHALL BE GROUNDED USING COAX GROUNDING KITS AT A MINIMUM OF TWO POINTS. INCLUDING AT ANTENNA AND AT MASTER GROUND BAR. THE COAXIAL CABLE SHALL NOT EXCEED 100 FEET BETWEEN GROUNDING KITS. C. GROUNDING CONDUCTOR CONSISTING OF $2 AWG TINNED SOLID BARE COPPER WIRE SHALL BE BONDED TO WAVEGUIDE ENTRY GROUND BAR USING CADWELD CONNECTIONS. D. COAX CABLE ENTERING A BUILDING SHALL BE GROUNDED WITH COAX GROUNDING KITS TO AN INSULATED COAX GROUND BAR WHICH SHALL BE INSTALLED ON THE OUTSIDE FACE OF THE BUILDING, BELOW THE CABLE ENTRY PORTS. E. WHEN COAX CABLES ENTER A BUILDING FROM A TOWER, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO THE EXTERNAL GROUND RING USING #2 AWG BARE TINNED SOLID COPPER ISOLATED IN PVC CONDUIT. F. WHEN COAX CABLES ENTER A BUILDING FROM A ROOF TOP, THE COAX GROUND BAR AT THE BUILDING SHAL BE CONNECTED TO THE MASTER GROUND BAR NEAR BTS USING Q2 AWG STRANDED INSULATED COPPER CONDUCTOR (SEE C. METAL RACEWAYS, ENCLOSURES, FRAMES AND OTHER NON —CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT SHALL BE KEPT BUILDINGS NOTES ON THIS DRAWING FOR CONNECTION TO PRINCIPLE GROUND BAR AND BUILDING GROUND). AT LEAST 6 FEET AWAY FROM LIGHTNING ROD CONDUCTORS OR THEY MUST BE BONDED TO LIGHTNING ROD CONDUCTORS AT THE LOCATION WHERE SEPARATION DISTANCE IS LESS THAN 6 FEET. G. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DOCUMENTS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION D. A MASTER GROUND BAR (MGB) SHALL BE INSTALLED NEAR BTS WITH BUILDING PRINCIPAL GROUND BAR (BPG) INSTALLED NEAR MANAGER UPON COMPLETION OF THE PROJECT. ENTRANCE OF MAIN META COLD WATER PIPE INTO BUILDING. A 4 AWG RA V L L G. j{ /0 G STRANDED COPPER DOWN CONDUCTOR (VERTICAL GROUND RISER) SHALL BE USED TO INTERCONNECT GROUND BARS. E. VERTICAL RISER SHALL CONSIST OF A #4/0 AWG (THAN) STRANDED COPPER CONDUCTOR INSIDE 3/4" CONDUIT. F. CONTRACTOR SHALL BE BOND BUILDING PRINCIPAL GROUND BAR (BPG) NEAR MAIN METAL COLD WATER PIPE TO EXISTING BUILDING GROUND RING AS WELL AS TO MAIN COLD WATER PIPE WITH S4/0 AWG (THWN) STRANDED COPPER CONDUCTOR. G. ANTENNA GROUND BARS (AGE) SHALL BE INSTALLED NEAR ANTENNAS AND SHALL BE BONDED TO MASTER GROUND BAR (MGB) WITH #2 AWG TINNED SOLID BARE COPPER CONDUCTOR. H. IF CODES REQUIRE VERTICAL RISER TO BE ISOLATED IN CONDUIT, PVC CONDUIT IS PREFERRED. IF METALLIC CONDUIT IS USED, GROUNDING BUSHINGS SHALL BE INSTALLED ON EACH END OF THE CONDUIT AND BONDED TO GROUND BARS USING #2 AWG (THWN) STRANDED COPPER CONDUCTORS WITH GREEN INSULATION. 11. LAND BUILDS AND CO —LOCATES A. THE GROUND ELECTRODE SYSTEM SHALL CONSIST OF DRIVEN GROUND RODS UNIFORMLY SPACED AROUND THE EQUIPMENT FOUNDATION AND AROUND THE PERIMETER OF THE TOWER FOUNDATION. THE GROUND RODS SHALL BE 5/8" X 10'-0" COPPER CLAD STEEL INTERCONNECTED WITH #2 SOLID TINNED BARE COPPER GROUND CONDUCTOR TO FORM A GROUND RING AT A DEPTH OF 30 INCHES BELOW THE SURFACE OF THE SOIL A MINIMUM OF 1 FOOT AND A MAXIMUM OF 3 FEET CLEARANCES SHALL BE MAINTAINED FROM FOUNDATIONS. TOWER AND EQUIPMENT GROUND RINGS SHALL BE INTERCONNECTED WITH TWO GROUNDING CONDUCTORS OF EQUAL LENGTH AND MATERIALS. B. GROUND RODS SHALL BE BONDED TO GROUND RINGS AND INTERCONNECTING CONDUCTORS AT EQUAL INTERVALS OF APPROXIMATELY 10 FEET. C. WAVEGUIDE BRIDGE SHALL BE BONDED TO GROUND RINGS OR INTERCONNECTING CONDUCTORS WITH GROUNDING CONDUCTORS BONDED TO DIAGONALLY OPPOSED SUPPORT POSTS. D. GROUND BARS SHALL BE BONDED TO GROUND RING WITH SINGLE GROUNDING CONDUCTOR. E. BONDS TO ANTENNA MAST, FENCE POSTS, WAVEGUIDE BRIDGE, TOWER STEEL (UNLESS PROHIBITED BY TOWER MANUFACTURER) AND THOSE BELOW GRADE SHALL BE EXOTHERMIC TYPE (CADWELD). ALL OTHER BONDS SHALL BE BRONZE 2—HOLE COMPRESSION FITTINGS UNLESS OTHERWISE NOTED. F. GROUNDING CONDUCTORS MAKING A TRANSITION FROM ABOVE TO BELOW GRADE SHALL BE INSULATED FROM EARTH CONTACT BY PASSING THROUGH A PVC CONDUIT. THE CONDUIT SHALL EXTEND AT LEAST 6 INCHES ABOVE AND 12 INCHES BELOW GRADE LEVEL 12. LIGHTING PROTECTION A. IF EXISTING BUILDING HAS AN NFPA 780 AIR TERMINAL SYSTEM, EXISTING SYSTEM SHALL BE BONDED TO A GROUND BAR TO BOND THE EXISTING SYSTEM TO THE NEW SYSTEM. SHOULD THE EXISTING SYSTEM COME WITHIN 8 FEET OF ANTENNA STRUCTURES, EXISTING SYSTEM SHALL BE BONDED TO COAX GROUND BARS. B. IF SITE IS IN A HIGH RISK AREA AND ANTENNAS DO NOT FALL WITHIN EXISTING CONE OF PROTECTION FOR BUILDING, AIR TERMINALS SHALL BE INSTALLED AT ANTENNAS. A SINGLE AIR TERMINAL MAY BE USED WHEN TWO ANTENNAS ARE MOUNTED ON SAME STRUCTURE AND IT HAS BEEN DETERMINED THAT BOTH ANTENNAS WILL FALL WITHIN LIGHTING CONE OF PROTECTION FOR SINGLE AIR TERMINAL. H. GUARANTEE/WARRANTY: GUARANTEE INSTALLATION TO BE FREE OF DEFECTS, SHORTS, GROUNDS, ETC., FOR A PERIOD OF ONE YEAR. FURNISH WARRANTY SO THE DEFECTIVE MATERIAL AND/OR WORKMANSHIP WILL BE REPAIRED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO THE OWNER FOR PERIOD OF WARRANTY. I. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. J. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E- RIGID PVC SCHEDULE 40. OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. K. LIQUID —TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID—TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. L. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY —COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. M. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY —COATED OR NON —CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1: AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. N. NONMETALLIC RECEPTACLES, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 0. CONTRACTOR SHALL PREFER TO SPRINT GROUNDING AND BONDING PRACTICE. ADDITIONAL RF NOTES/ CONSTRUCTION REQUIREMENTS 1. AISG TESTS TO VERIFY OPERATION IS TO BE PERFORMED AFTER FINAL INSTALLATION OF ANTENNAS AND AISG CABLES HAVE BEEN CONNECTED. VERIFY OPERATION OF ALL EXISTING SPRINT AISG EQUIPMENT INCLUDING 800 MHZ, 1.9GHZ AND 2.5G. TEST INCLUDE COMPLETE DOWNTILT, AZIMUTH (IF APPLICABLE). DOCUMENT AISG TEST RESULTS IN COAX SWEEP TEST SPREADSHEET. 2. GENERAL CONTRACTOR MUST INSURE THAT NO OBJECT IS LOCATED IN FRONT OF ANTENNA THIS MEANS NO OBJECT IS TO BE LOCATED 45 DEGREES LEFT AND RIGHT OF FRONT OF ANTENNA OR 67.5 DEGREES FROM HORIZONTAL FROM TOP AND BOTTOM OF ANTENNA. IF THIS IS NOT POSSIBLE, CONTACT RF ENGINEER FOR FURTHER INSTRUCTION. IN ADDITION, 2.5G ANTENNA IS NOT TO BE PLACED IN FRONT OF ANY OTHER ANTENNA USING THE SAME RULES AS ABOVE. THIS INCLUDES SPRINT AND NON —SPRINT ANTENNAS. 3. GENERAL CONTRACTOR IS REQUIRED TO USE DIGITAL ATTACHMENT TOOL TO SET AZIMUTH, ROLL AND DOWNTILT. AZIMUTH ACCURACY IS TO BE WITHIN 3 DEGREES. DOWNTILT AND ROLL (LEFT TO RIGHT TILT) IS TO BE WITHIN 0.1 DEGREES. IF FOR SOME REASON THIS ACCURACY CANNOT BE ACHIEVED, UPDATE AS —BUILT DRAWING AND EMAIL SPRINT RF ENGINEER WITH AS —BUILT SETTINGS. USE 3Z RF ALIGNMENT TOOL OR EQUIVALENT TOOL. HTTP://WWW.3ZTELECOM.COM/ANTENNA—ALIGNMENT—TOOL/ Sprint 6560 Sprint Parkway Overland Park Kansas 66251 INFINIGY9 FROM ZERO TO INFINIGY Poe solMBons are enClem 1401 TONN PI Cr SUITE 0 W NTER SPRINGS, FL 3Z100 o .OeU....w JOB NUMBER 317-94 AM=RICAN TOW=R CORPORATION 116 HUNTINGTON AVENUE, I ITH FLOOR BOSTON. MA 0118 11111111111111/ % OpHER ,/ ���i� \5 .• ...E NSF .qq� * : N 59739 2 *L D s nrE 5-04-18 p'. OF 4U �. :4 ON A LIE ORAWNGNOTILE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. FORT DRUM MI13XC161 25560 MINUTE MAID RD FORT PIERCE, FL 34945 GENERAL NOTES SHEET NUMBER: I� GENERAL CONSTRUCTION NOTES GENERAL A. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. B. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE UNDERGROUND UTILITIES. C. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH ACTION SHALL REQUIRE APPROVAL. D. EACH CONTRACTOR SHALL COOPERATE WITH THE OWNER'S REPRESENTATIVE, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. E. PAINT ALL ANTENNAS, MOUNTING HARDWARE, CABLES, CABLE TRAYS, ETC. TO MATCH EXISTING STRUCTURE PER OWNER REQUIREMENTS. OWNER SHALL APPROVE COLOR. F. ALL DAMAGED, MARRED, SCRAPED, ABRADED, ETC. AREAS OF EXISTING PAINT SHALL BE REPAIRED PER OWNERS REQUIREMENTS. OWNER SHALL APPROVE COLOR. 2. EXCAVATIONS/FOUNDATION A. FOUNDATION EXCAVATION SHALL BE HAND —TRIMMED TO REMOVE LOOSE MATERIALS. B. EXTERIOR FOUNDATION BACKFILL SHALL BE SELECTED GRANULAR FILL. C. ALL STRUCTURAL BACKFILL AND SUBBASE UNDER SLABS —ON —GRADE AND FOOTINGS SHALL BE "SW" OR BETTER PER ASTM D-2487 COMPACTED TO A MINIMUM 957 STANDARD PROCTOR DENSITY PER ASTM D 698. D. DO NOT PLACE FOOTINGS IN WATER OR ON FROZEN GROUND. E. SOIL BEARING SURFACES, PREVIOUSLY ACCEPTED BY GEOTECHNICAL ENGINEER, WHICH ARE ALLOWED TO BECOME SATURATED, FROZEN OR DISTURBED SHALL BE REWORKED TO SATISFACTION OF GEOTECHNICAL ENGINEER. F. DO NOT ALLOW GROUND BENEATH FOOTINGS TO FREEZE. G. FOOTING EXCAVATIONS SHALL BE CUT NEAT. 3. CONCRETE A. DESIGN AND CONSTRUCTION OF ALL CONCRETE ELEMENTS SHALL CONFORM TO THE LATEST EDITIONS OF THE FOLLOWING APPLICABLE CODES: ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS"; ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"; B. MIX DESIGN SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE. C. CONCRETE SHALL BE NORMAL WEIGHT, 6% AIR ENTRAINED (t1.57.) WITH A MAXIMUM 4" SLUMP, AND HAVE A MINIMUM 28—DAY COMPRESSIVE STRENGTH OF 3000 PSI UNLESS OTHERWISE NOTED. D. MAXIMUM AGGREGATE SIZE SHALL BE 1". E. THE FOLLOWING MATERIALS SHALL BE USED: PORTLAND CEMENT: ASTM C 150, TYPE I REINFORCEMENT: ASTM A 615, GRADE 60 NORMAL WEIGHT AGGREGATE: ASTM C 33 WATER: DRINKABLE ADMIXTURES: NON —CHLORIDE CONTAINING F. REINFORCING SHALL CONFORM TO ASTM A-615 WITH SUPPLEMENT. MINIMUM YIELD STRENGTH Fy= 60 KSI. REINFORCING DETAILS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ACI 315. G. CONCRETE COVER AROUND REINFORCING BARS (U.N.O.) SHALL BE: 1. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED EARTH ........ 3" 2. CONCRETE EXPOSED TO EARTH, WEATHER .........................2" 3. SLABS....................................................3/4" 4. ALL OTHER CONCRETE ..................................... 1 1/2" H. UNLESS INDICATED OTHERWISE ON THE DRAWINGS, REINFORCEMENT SPLICES SHALL MEET CLASS B. TENSION LAP REQUIREMENTS IN ACCORDANCE WITH ALL PROVISIONS OF ACI 318 LATEST EDITION, UNLESS NOTED OTHERWISE. GENERAL CONSTRUCTION NOTES CONT. I. CURING COMPOUNDS SHALL CONFORM TO ASTM C-309. J. ADMIXTURES SHALL CONFORM TO THE APPROPRIATE ASTM STANDARD AS REFERENCED IN ACI-301. K. DO NOT WELD OR TACKWELD REINFORCING STEEL. L. ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICAL CONDUITS, PIPE SLEEVES, PIPING, WATERSTOPS, INSERTS, GROUNDS AND ALL OTHER EMBEDDED ITEMS AND FORMED DETAILS SHALL BE IN PLACE BEFORE START OF CONCRETE PLACEMENT. M. LOCATE ADDITIONAL CONSTRUCTION JOINTS REQUIRED TO FACILITATE CONSTRUCTION AS ACCEPTABLE TO ENGINEER. PLACE REINFORCEMENT CONTINUOUSLY THROUGH JOINT. N. REINFORCEMENT SHALL BE COLD BENT WHENEVER BENDING IS REQUIRED. O. PLACE CONCRETE IN A UNIFORM MANNER TO PREVENT THE FORMATION OF COLD JOINTS AND OTHER PLANES OF WEAKNESS. VIBRATE THE CONCRETE TO FULLY EMBED REINFORCING. DO NOT USE VIBRATORS TO TRANSPORT CONCRETE THROUGH CHUTES OR FORMWORK. P. DO NOT PLACE CONCRETE IN WATER, ICE, OR ON FROZEN GROUND. Q. DO NOT ALLOW CONCRETE SUBBASE TO FREEZE DURING CONCRETE CURING AND SETTING PERIOD, OR FOR A MINIMUM OF 14 DAYS AFTER PLACEMENT. R. FOR COLD —WEATHER AND HOT —WEATHER CONCRETE PLACEMENT, CONFORM TO APPLICABLE ACI CODES AND RECOMMENDATIONS. IN EITHER CASE, MATERIALS CONTAINING CHLORIDE, CALCIUM, SALTS, ETC. SHALL NOT BE USED. PROTECT FRESH CONCRETE FROM WEATHER FOR 7 DAYS MINIMUM. S. PROVIDE A STEEL TROWEL FINISH TO THE SLAB. 4. ANTENNA SUPPORT BRACKET NOTE S ES IF APPLICABLE A. DESIGN RESPONSIBILITY OF ANTENNA MOUNTING BRACKETS AND POLES AND ALL COMPONENTS THERE OF AND ATTACHMENT THERE TO SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER. MFR SHALL PROVIDE TO THE ENGINEER FOR APPROVAL. DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY, INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT DATA. B. BRACKETS SHALL BE DESIGNED TO SUPPORT CURRENT AND FUTURE PANEL ANTENNAS AND COAXIAL CABLES AS SHOWN. 5. STRUCTURAL STEEL NOTES A. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". B. STEEL ANGLES, BASE PLATES, BEARING PLATES AND MISC. FABRICATION SHALL BE MADE FROM STEEL MEETING THE REQUIREMENTS OF ASTM—A36 WITH A MINIMUM YIELD STRESS OF 36 KSI. ALL STEEL TUBES AND PIPES SHALL BE A500 STEEL MINIMUM. C. ALL DINGS, SCRAPES, MARS, AND WELDS IN THE FINISHED AREAS SHALL BE REPAIRED BY FIELD TOUCH—UP PRIOR TO COMPLETION OF THE WORK. D. ALL EXTERIOR STRUCTURAL STEEL SHALL BE, WHEN DELIVERED, HOT —DIP GALVANIZED ACCORDING TO ASTM A123. TOUCH—UP FIELD WELDS AND ABRADED AREAS W/2 COATS OF GALVANIZED PAINT, ZRC COLD GALVANIZING COMPOUND OR APPROVED EQUAL. E. DO NOT PLACE HOLES THROUGH STRUCTURAL STEEL MEMBERS EXCEPT AS SHOWN AND DETAILED ON STRUCTURAL DRAWINGS. F. CONNECTIONS: 1. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALVANIZED ASTM A325 BOLTS AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 2. NON—STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. GALVANIZED ASTM A307 BOLTS UNLESS NOTED OTHERWISE. G. SAFETY NOTES: 1. THE CONTRACTOR WILL ADHERE TO ALL SAFETY REGULATIONS, LOCAL, STATE AND FEDERAL. 2. THE CONTRACTOR WILL CONDUCT DAILY SAFETY TAILGATE MEETINGS IN ADDITION TO WEEKLY SAFETY MEETINGS. THESE REPORTS NIL BE MADE AVAILABLE TO THE OWNER UPON REQUEST. 3. ALL WORKERS & VISITORS TO THE SITE SHALL WEAR HARD HATS & ANY OTHER SAFETY EQUIPMENT REQUIRED BY THE WORK BEING PERFORMED ON THE SITE. Sprint 6580 Sprint Parkway Overland Park Kansas 66251 INFINIGY9 FROM ZERO TO INFINIGY INe .owBolR me enalea 1441 TOM P CT SMITE]No WNTER SPRINGS, FL WOO JOB NUMBER E17-404 AMERICAN TOWER CORPORATION 1I6 HUNTINGTON AVENUE 11TH FLOOR BOSTON. MA Ml 18 1111111111111,I \��Op HER j `GAP•••• ..ENS�999�- N 59739 2 :* 33• STATE 5-04-18 : Q` O F lV OpR1OP���44,: oi,!ONAL ORAWNG NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. FORT DRUM SITECASCADE: MI13XC161 25560 MINUTE MAID RD FORT PIERCE, FL 34945 GENERAL NOTES SHEVNWBER: N-3 PREPARED FOR: 10' NO SPARK BUFFER EXISTING PROPANE TANK ENRWJCE GATE x I / x EXISTING UTILITY H-FRAME (TYP ) x L—x x x x x Y EXISTING S'xIO' CONCRETE PAD x x x EXISTING GENERATOR PAD X71!j x x 6TING SPRINT 12'x9' CONCRETE PAD (3) PROPOSED HYBRIFLEX CABLES TO BE ROUTED ALONG EXISTING ICE BRIDGE AND SECURED WITH SNAP IN HANGERS EXISTING GUYED TOWER \ I \ \TIx I \x I EXISTING FENCE x I x x x x x 2.5' 0 2.5' 5' 10' Sprint IP 6580 Sprint Parkway Ovedand Park, Kansas 66251 IRNFINIGY9 FROM ZERO TO INFINIGY Me solution are endless 1401 TOWN PU CT. SUITE 2W0 WINTER SPRINGS, R 32MO a .Sea. JOB NUMBER 317-104 AM=.RICAN TOWER CORPORATION 11SHUNUNGTONAVENUEIITHFLOOR BOSTON, MA02116 ENGINEERING LICENSE: ``ATTTEEEy/AA�� �0 HER jtp F • Q 9F N 59739 2 ' STATE 5-04-18 'OF �. O R I O P\4U� ..ON A L .%-%%, THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. FORT DRUM MI13XCI61 25560 MINUTE MAID RD FORT PIERCE, FL 34945 COMPOUND PLAN SHEETNUMBER: C-1 TOWER ELEVATION ±400' GUYED TOWER SPRINT ANTENNAS 0 211' A.G.L. FXISDNG: (2) EXISTING PANEL ANTENNAS (2) EXISTING RRUS-11 800 MHZ (2) EXISTING RRUS-31 (1) EXISTING DISH ADDING: (3) NEW COMMSCOPE DT465B-2XR ANTENNAS (3) NEW RFS APXVSPPI8-C-A20 ANTENNAS (3) NEW RRUS-82 W/ SOLARSHIELD (4) NEW RRUS-11 800 MHZ (1) NEW RRUS-31 (3) NEW 1.25• HYBRIFLEX CABLES BETA SECTOR (TYP. OF 1 PER SECTOR, TOTAL OF 2) EXISTING SPRINT RRU (TYP. OF 1 PER SECTOR, TOTAL OF PROPOSED CONNECT yT HEAVY --DUTY V-fRAME BOOM GATES MODEit193-JO-B-LHD OR APPROVED EQUAL (TYP. OF 3 TOTAL) EXISTING SPRINT RRU z\D'a> (TYP. OF 1 PER SECTOR, TOTAL OF 2) GAMMA SECTOR ?� EXISTING SPRINT ANTENNA TO BE REMOVED (TYP. OF 1 PER SECTOR, TOTAL OF 2) ALPHA SECTOR FYMdi9l3Hf114}.YVJ �� PROPOSED SPRINT ANTENNA �(TYP. OF 1 PER SECTOR, TOTAL OF 3) P ao ALPHA SECTOR P^' �o PROPOSED SPRINT ANTENNA Y,(TYP. OF 1 PER SECTOR, TOTAL OF 3) PROPOSED SPRINT RRU (TYP. OF 1 PER SECTOR, TOTAL OF 3) EXISTING SPRINT RRU (TYP. OF 1 PER SECTOR, TOTAL OF 2) PROPOSED SPRINT RRU N (TYP. OF 1 PER SECTOR, TOTAL OF 1) PROPOSED SPRINT RRU (TYP. OF 1 PER SECTOR, TOTAL OF 4) S AK OF TOWER = to-D ACL BETA SECTOR SCALE:NOTTOSCAIE 1 1 PROPOSED ANTENNA PLAN SCALE:NOTTOSCALEI 3 Sprint 6580 Sprint Parkway Overland Park Kansas66251 PL SPREPAREDBY: INFINIGY9 FROM ZERO TO INFINIGY the solutions are endless 1401 TOWN PL CT. SUITE]NO VANTERSPRINGS.FL3v:' ars,l[rN�R AB NUMBER 317-404 Mf PARTNER: AM=RICAN TOW=R CORPORATION 11811UNTINGTONAVENUE IITHFL00R BOSTDN. MAW 116 ``IIIIIIIII///j ����CIPHER Ur �y .C•E•N•• 59739 2 ) : 5-04-18 : Z+ srarE O F ZZf �RGN LE���`� THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHEEXPRESS WRITTEN CONSENTOF SPRINT. ISSUED FOR OONSTRUMION 102/13/181 JTP1 0 1 FORT DRUM SITE CASCADE MI13XCI61 SITEADDRESS: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 TOWER ELEVATION AND ANTENNA ORIENTATION SHEETNUMBER /'/� C-2 PLANS PREPARED FOR: ANTENNA MOUNTING POLE (' NOTES: 1. AISG TESTS TO VERIFY OPERATION IS TO BE PERFORMED AFTER FINAL INSTALLATION OF ANTENNAS AND AISG CABLES HAVE BEEN CONNECTED. VERIFY OPERATION OF ALL EXISTING SPRINT AISG EQUIPMENT INCLUDING BOOMHZ, 1.9GHZ AND 2.5GHZ. TEST INCLUDES COMPLETE DOWNTILT, AZIMUTH (IF APPLICABLE) AND BEAMWIDTH SWINGS (IF APPLICABLE). DOCUMENT AISG TEST RESULTS IN COAX SWEEP TEST SPREADSHEET. 2. GENERAL CONTRACTOR MUST ENSURE THAT NO OBJECT IS LOCATED IN FRONT OF ANTENNA. THIS MEANS NO OBJECT IS TO BE LOCATED 45 DEGREES LEFT AND RIGHT OF FRONT OF ANTENNA OR 67.5 DEGREES FROM HORIZONTAL FROM TOP AND BOTTOM OF ANTENNA IF THIS IS NOT POSSIBLE, CONTACT RF ENGINEER FOR FURTHER INSTRUCTION. IN ADDITION, 2.5GHZ ANTENNA IS NOT TO BE PLACED IN FRONT OF ANY OTHER ANTENNA USING THE SAME RULES AS ABOVE. THIS INCLUDES SPRINT AND NON —SPRINT ANTENNAS. 3. GENERAL CONTRACTOR IS REQUIRED TO USE A DIGITAL ALIGNMENT TOOL TO SET AZIMUTH, ROLL AND DOWNTILT. AZIMUTH ACCURACY IS TO BE WITHIN 3 DEGREES. DOWNTILT AND ROLL (LEFT TO RIGHT TILT) IS TO BE WITHIN 0.1 DEGREES. IF FOR SOME REASON THIS ACCURACY CANNOT BE ACHIEVED, UPDATE AS —BUILT DRAWINGS AND EMAIL SPRINT RF ENGINEER WITH AS —BUILT SETTINGS. US 3Z RF ALIGNMENT TOOL OR EQUIVALENT TOOL HTTP://WWW.3ZTELECOM.COM/ANTENNA—AUGNMENT—TOOL/ PROPOSED MOUNTING BRACKET (TYP) PROPOSED ANTENNA (TYP) PROPOSED MOUNTING BRACKET (TYP) ANTENNA MOUNTING DETAIL SCALE:NOTTOSCALEI 1 I LW 1 SCALE: NOT TO SCALE I 2 NOTE: DETAIL IS DIAGRAMMATIC. CONTRACTOR TO INSTALL RRU'S AND/OR RRU'S W/A2 MODULES ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. ISO VIEWS RRU SUPPORT KIT (IF SUITABLE) OR ERICSSON RRU SUPPORT KIT (WHERE REQUIRED) RRU TOP VIEW NOTES: 1. UNIT SHALL BE MOUNTED AS PER MANUFACTURER'S RECOMMENDATIONS. 2. CONTRACTOR SHALL TIGHTEN ALL BOLTS TO A 'SNUG TIGHT' CONDITION AS DEFINED BY AISC. RRU RRU BACK VIEW 1RT KIT (IF SUITABLE) OR RRU SUPPORT KIT (WHERE Sprint 650D Spdnt Parkway Overland Park, Kansas 66251 INFINIGY9 FROM ZERO TO INFINIGY Me solution. Rre endless Am TWA1 PLVd Or. SUITE 940 .NTER SPRINGS. FL ST.. olw.lemlu...n .DB NWBER 317-404 /1mEmc km TOWER CORPORATION 116 HUNENGTON AVENUE I ITH FLOOR BOSTON. MA C2116 ENGINEERING LICENSE: 1111111111ff/fI y�OPHER UrL���i ``�P\ Al S `q9 6: No 9739 9�2 •T: * lam;* 5-04-18 ;jZ TA E - OF 40 . O R I O P�,����`• ONALE,���`� DRAWNG NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE I BY REV ISSUED FOR OMTRUCTIW 02/13/18 0 O MED NR RENEW DI/D4/18 JR A FORT DRUM SITE GISCADE: MI13XC161 25560 MINUTE MAID RD FORT PIERCE, FL 34945 DETAILS SHEEP NUMBER: SCALE: NOT TO SCALE j C 3 7" SIDE FRONT MANUFACTURER: RFS MODEL: APXVSPPI8—C—A2O WEIGHT: 57 LES ANTENNA DETAIL MANUFACTURER: ERICSSON MODEL' RRUS-11 WEIGHT: 50.7 LBS RRUS DETAIL SCALE: NOT TO SCALE I 1 SCALE NOT TO SCALE I 4 SIDE 8 2" FRONT MANUFACTURER: COMMSCOPE MODEL: DT465B-2XR WEIGHT: 58 LDS ANTENNA DETAIL 0000 13.8• TOP SCALE: NOTTO SCALE I 2 15" FRONT MANUFACTURER: ERICSSON MODEL: RRUS-82 WEIGHT: 62.,LBS TOP RRUS DETAIL ISCALE:NOTTOSCALEI 3 Sprint 6580 Sprint Parkway Overland Park Kansas 66251 PIANSPREPAREDBY: INFINIGY9 FROM ZERO TO INFINIGY Me solMHons ore endless 1401 TOM PLAZA Ci SUITE 2040 WINTER SPRINGS FL TOOB tina.IFlR u..� JOB NUMBER 317-404 AMERICAN TOW=R CORPORATION 118 HUNTINGTON AVENUE, IITH FLOOR BOSTON, MA 0211E 1111111111///j, ����y�OPNER A/ ZP� C N8F�9q� .; N 59739 J31 T. TE 5-04-18 :AZ OF l[y� 'Os.<ORIOPGN�<4`� ONZOE tt%%" L-A—I 6 16 11'B SIDE VIEW i0 11.8' PLAN VIEW MANUFACTURER: ERICSSON MODEL: RRUS-31 WEIGHT: 56.1 LBS e 11.8" FRONT VIEW THE SOLE PROPERTY OF SPRINTAND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. PEMSIONS: DESCRIPTION OATS BY REV MUM FOR 014TRUCTIM 02/13/18 JIP 0 IS9JO1 FOR NEON 01/04/I8 JIP A SITE NAME: FORT DRUM SITE CASCADE MI13XCI61 SITE ADDRESS: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 GHEET DESCRIPTION: DETAILS SHEET NUMBER: C-4 RRUS DETAIL SCALE NOT TO SCALE 5 NOT USED ALE:NOTTOSCALE Is 6 NOTE: 1. EXACT ROUTING OF CARIES TO BE DETERMINED BY STRUCTURAL ANALYSIS (BY OTHERS) GPS H-FRAME POST CONCRETE PROPOSED CONNECT —IT HEAVY—DUTY V—FRAME BOOM GA 7ES MDDEZ/ VFIJ—JO—B—[HD EXISTING CABINETS ON EXISTING CONCRETE PAD HYBRIFLEX TOWER CABLES FROM REAR OF CABINET ROUTED ON EXISTING CABLE BRIDGE CABLES ATTACHED TO EXISTING GUYED TOWER SCALE:NOTTOSCALEI 4 Sprint ,110110 6500 Sprint Parkway Overland Pally Kansas 66251 PUNS PREPARED SY: INFINIGY9 FROM ZERO TO INFINIGY Me.oluNOn. are erdl.. 1401T0w4FLATACT.SCItE2040 WW ER SPRINGS,FL='n m .Mn. JOB MINBER 317-404 A M=RIC %N TOW=R CORPORATION 116 HUNTINGTON AVENUE, I ITH FLOOR BOSTON, MA M116 ENGINEERING LICENSE 1111111111111j/ %1 OPHER J kk % 5 tee \ E N sF g9p'y U 59739 2 0'• S ATE s-oa-ta:�` OF //1S/.ONAL E.-,t.+. DRAIMNG NOTICE THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINTAND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. O%SmocnoN FORT DRUM, MI13XC161 SITE ADDRESS: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 DETAILS SHEET NUMBER: l/�I SCALE: NOT TY) SCALE 4 v S ANTENNA & CABLE SCHEDULE ANTENNA SECTOR ANTENNA MODEL # ANTENNA CABLE DESCRIPTION ANTENNA CABLE VERTICAL LENGTH ANTENNA CABLE HORIZONTAL LENGTH (P) RFS APXVSPPI8—C—A20 ALPHA (P) COMMSCOPE DT4658-2XR (1) 1.25" HYBRIFLEX CABLE (P) 211'-0" 30,-0" (P) RFS APXVSPPI8—C—A20 BETA (P) COMMSCOPE DT465B-2XR (1) 1.250 HYBRIFLEX CABLE (P) 211'-0" 30,-0" (P) RFS APXVSPPIB—C—A20 GAMMA (P) COMMSCOPE DT465B-2XR (1) 1.25" HYBRIFLEX CABLE (P) 211'-0" 30,-0" NOTE: HORIZONTAL DIMESIONS HAVE BEEN ESTIMATED FROM THE WIDEST PORTION OF THE TOWER Sprint 658D Sprint Parkway Overland Park, Kansas 66251 INFINIGY9 FROM ZERO TO INFINIGY The 301UNons we endless NOt TOWN PLAZA CT. SLATE ]MO WATER SPAING; FL,vm arts. e/flu.u¢1 JOB NUMBER 317-w4 AMERICAN TOWER CORPORATION 116HUNTINGTCN AVENUE. I ITH FLOOR BOSTON. MA RI IS %II I I I11181 OPHER J tL N 59739 2 v: y ;• s—oa—I e : � 5,TA TE OF • l(/ DRAWNG NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPROOUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. FORT DRUM SITECASCADE: MI13XC161 SITE ADDRESS: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 SHEETDESCRIPTION: ANTENNA & CABLE SCHEDULE SHEETNUMBER: C-6 PROPOSED RRU (TYP.) (CONFIRM WITH LATEST RFDS FINAL COUNT AND MODEL NUMBERS) — EXISTING GROUND BAR (TYP. PER SECTOR) — PROPOSED H6 AWG PROPOSED #6 AWG INSULATED COPPER CONDUCTOR — TO TOWER BOTTOM GROUND BAR ANTENNA MOUNTING PIPE SPRINT ANTENNA PROPOSED #2 AWG BARE SOLID TINNED COPPER CONDUCTOR RRU STAINLESS STEEL HARDWARE GROUNDING ELEVATION TWO HOLE COPPER COMPRESSION TERMINAL GROUNDING BAR Sprint 6560 Spnnt Parkway Overland Park Kansas 66251 INFINIGY9 FROM ZERO TO INFINIGY fhR •.I.N.n. are..Clem 1401 TOWN PLAZA CT. s MMD WNER SPRING FL n?Na ..1R N.u9 JOB NUMBER 317-404 AMERICAN SHER (TYP.) FLAT WASHER (TYP.) TOWER (TYP.) CCRPOR4TION 1/2"X1-1/2' HEX BOLT IIe HUNTNGMNAENUE, IITH FLOOR NUT (TYP.)ING (STAINLESS STEEL) BOSTON,Mmm�S GROUND BAR GROUNDENGINEERINGUCENSE: CABLE EXPOSED BARE COPPER TO BEKEPT TO NO NSULATIONBSOLUTE ALLLOWEDMWITHIN THE %%`,` ER SECTION "A —A" COMPRESSION TERMINAL (TYP.)�E NS,. NOTE: - : �' F % 1. 'DOUBLING UP" OR "STACKING" OF CONNECTIONS IS NOT PERMITTED. 0 59739 EXISTING •. •L 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. *� • `—Ili �•, 5-04—I8 *.,,,STATE OF � TYPICAL GROUND BAR CONNECTION DETAIL SCALE:NOTTOSCALE 2 'q�ONALENC�40 SCALE: NOTM SCALE I I NOT USED I SCALE: NOT TO SCALE DIRAWNG NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. FORT DRUM SITE CASCADE MI13XC161 SITE ADDRESS: 25560 MINUTE MAID RD FORT PIERCE, FL 34945 SHEETDESCRIPTION: GROUNDING DETAIIS SHEETNIRABER: G-1 TYPE 2 CONFIGURATION Existing Future SCALE: NOTTOSCALE Sprint 6580 Sprint Parkway Ovedand Park, Kansas 66251 INFINIGY8 FROM ZERO TO INFINIGY Me solutions are andles 1401 TQMIPL CT surtE200 MWER SPRINGS, FL3,705 Em••ARI•.FAua JOB RIBBER 317-404 J*A=RIC UM TOW=R CORPORATION I I6 HUNNNGTON AVENDB I ITH FLOOR BOSTON. BA M116 11j1111111ff//I %� OpHER I/ * : N 1 59739 9 '• rArE 5-04-18 :jr cf O R I O P C?\=,��. NAL S..%%%• DMWINGN07CE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. SHEET NUMBER: 1 A 1 FREQUENCY COLOR CODE EXAMPLE SECTOR 2 AND CABLE 2, (800MWz RADIO 91) EXAMPLE SECTOR 3 AND CABLE 1, (1900MHz RADIO SI) EXAMPLE SECTOR 2 AND CABLE 4, (8WMHz RADIO Al AND I900.WIz RADIO HI) 'ATOR NOTES: #2 1. ALL CABLES SHALL BE MARKED WITH 2- WIDE, UV STABILIZED, UL APPROVEDTAPE. RRH CABLE MARKING LOCATIONS DIAGRAM CABLE MARKING LOCATION TABLE TAPE TAG LOCATION X EACH TOP -JUMPER SHALL BE COLOR CODED WITH (1) SET OF 3- WIND BANDS. EACH MAIN CABLE SHALL BE COLOR CODED WITH(1)SET OF 3- WIDE BANDS NEAR THE X TOP-JIDWER CONNECTION AND PRIOR TO ENTERING THE BTS OR TRANSMITTER BUILDING. X MARKINGTAGSSHALLBEATTACHEDAT CABLE ENTRY PORT ON THE INTERIOR OF THE SHELTER ALL BOTTOM JUMPERS SHALL BE COLOR CODED WITH SET OF 314'WIDE BANDS ON X EACH END OF BOTTOM JUMPER. 2500MHz RADIO CALIBRATION CABLE COLOR CODE 2500 MHz k1 CAL CABLE -SECTOR CABLES FIRSTRING SECOND RING THIRD WNG FOURTH RING FIFTH RING SIXTH RING I ALPHA I _ aCLOWr [YELLOW WHITE -� 2 BETA 2 yYELLOW: .,!YELLOW]-- - .)rYF1LOW' WHITE - 3GAMMA 3 VELLBW IYELLOWI YELLOW- - rELL W WHITE 2500 MHz R2 CAL CABLE -SECTOR CABLES FIRSTRING SECOND RING THIRD RING FOURTH RING FIFTH RING SIXTH RING I ALPHA I _ YELLOW!- YELLOW PURPLE - YELLOW; - �ELOW. LYELLOWj PURPLE rELL W „ �YELLOWj YELELLOW� IYELLO - 2BETA 2 _ PURPLE 3 GAMMA 3 I THE FIRST RING SHALL BE CLOSESTTO THE END OF THE CABLE AND SPACED APPROXIMATELY 2- FROM THE END CONNECTOR, WEATHERPROOFING. OR BREAK-0UT CYLINDER THERE SHALL BE A 1' SPACE BETWEEN EACH RING FOR THE CABLE IDENTIFIER, AND NO SPACES BETWEEN THE FREQUENCY BANDS, 3, A 2' GAP SHALL SEPARATE THE CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE THE 2- COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO SPACES. 4. THE 2- COLORED TAPE(S) SHALL EACH BE WRAPPED A MINIMUM OF 3 TUBES AROUND THE INDIVIDUAL CABLES, AND THE TAPE SHALL BE KEPI' IN THE SAME LOCATION AS MUCH AS POSSIBLE. 5. SITES WITH MORE THAN FOUR (4) SECTORS WILL REQUIRE ADDITIONAL RINGS FOR EACH SECTOR, FOLLOWING THE PATTERN. HIGH CAPACITY SITES WILL USE THE NEXT COLOR IN THE SEQUENCE FOR ADDITIONAL CABLES IN EACH SECTOR- 6. HYBRID FIBER CABLE SHALL BE SECTOR IDENTIFIED INSIDE THE CABINET ON FREQUENCY BUNDLES, ON THE SEALTITF, ON THE MAIN LINE UPON EXIT OF SEALTTTE, AND BEFORE AND AFTER THE BREAKOUT UNIT (,MEDUSA), AS WELL AS BEFORE AND AFTER ANY ENTRANCE OR EXIT, T. HFC'MAIN TRUNK' WILL NOT BE MARKED WITH THE FREQUENCY CODES, AS IT CONTAINS ALL FREQUENCIES. 8. INDIVIDUAL POWER PATRS AND FIBER BUNDLES SHALL BE LABELED WITH BOTH THE CABLE AND FREQUENCY. SPRINT CABLE COLOR CODE SECTOR GABLE FIRST RING SECOND RING THIRD RING I ALPHA I GREEN NOTAPE NO TAPE 2 BLUE NOTAPE NOTAPE 3 BROWN NOTAPE NOTAPE 4 WHITE NOTAPE NO TAPE 5 REO NO TAPE NOTAPE 6 GREY NO TAPE NOTAPE T 8 PURPLE ORANGE NO TAPE NOTAPE NOTAPE NOTAPE 2 BETA I GREEN GREEN NOTAPE 2 BLUE BLUE NOTAPE 3 BROWN BROWN NOTAPE 4 WNITE WHITE NOTAPE 5 REO REO NOTAPE 6 GREY GREY NOTAPE 7 B PURPLE ORANGE PURPLE ORANGE NOTAPE NOTAPE 3GAMMA 7 2 3 4 5 6 GREEN BLUE BROWN WHITE RED GREY GREEN BLUE BROWN WHITE RED GREY GREEN BLUE BROWN WHITE RED GREY 7 8 PURPLE ORANGE PURPLE ORANGE PURPLE ORANGE Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 INFINIGY8 FROM ZERO TO INFINIGY B1e 3010003 are endlev 1.01 TOWN PVTA CI. surtE 1.1 WMER SPRINGS. FL U700 ab.nNn..•..m JOB NUMBER 317-/04 AWERICAN TOWER CORPORATION 116 HUNTINGTON AVENUE, IITH FLOOR BOSTON. MA M116 ENGINEERING LICENSE: `,11111111ff1ff \y�Op HER J tk!'�i�i q U' No 59739 9�Z �33 S ATE 5-04-18 :�'� %0 . .o OF •441�: CpR1�P�N�%.. 0NALS. ,o%• THESE DOCUMENTS ARE CONFI OENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITH OUT THE EXPRESS WRITTEN CONSENT OF SPRINT. MI13XC161 25560 MINUTE MAID RD FORT PIERCE, FL 34945 ANTENNA & CABLE COLOR CODING LL_ _ • •' •� �. SCALE: NOT TO SCALE I ill RF 2